CASE DESIGN & FIELD SERVICE PARTS LIST, CONT’D: LED LIGHT / PLUG / THERMOMETER
5. LED Light
LED lights are located at both header and
shelving of case (as shown below).
Check that ALL of the light plugs are properly
connected to the LED light.
See
TROUBLESHOOTING
section in manual
if LED lights malfunction.
6. LED Light Plug
LED lights are located at both header and
shelving of case (as shown below).
Check that ALL plugs are properly connected to
the LED lights.
Plug must be inserted ALL THE WAY into the
LED light orifice (with no gap) to work properly.
7. Thermometer
Thermometer provides air temperature of
heated section of case.
Thermometers DOES NOT provide actual food
temperature.
Use probe thermometer to
determine actual product
temperatures.
Model NE4835HSSV Slide-In Unit
(Shown) May Not Exactly Reflect
Every Feature or Option of
Your Particular Case.
FIELD SERVICE PARTS LIST: LED LIGHTS / PLUGS / THERMOMETER
P/N
COMPONENT NAME
AMT
P/N
COMPONENT NAME
AMT
25
LED LIGHT (ALSO CALLED OUT
ON PREVIOUS PAGE)
1
27
THERMOMETER
1
26
PLUG, LED LIGHT
1
25
26
27