Technical data
38
Operating instructions SVCD(S)
123456278
-
419A58
Elektrotechnische Anlagen GmbH
1
3.3.7
SKS-module
To decrease the low frequency harmonic back effects to mains a filter module
REVCON
SKS-R may connected to the power feedback unit (refer to figure 4.4.1.1.1).
In tables 3.3.5.1 to 3.3.5.5 the power feedback units are assigned to the corresponding
SKS-R module types. If the harmonic distortion of the uninfluenced mains voltage THD
U is lower than 2% and the ratio of short circuit power and installed power R
SCE
is at
least 66, the THD I of the mains current of the power feedback unit improve to typical
10% (max. 15%).
REVCON
®
- type
Order designation for module
Case type
SVCD(S) 4-230-1-0
SKS-R 4-230
A
SVCD(S) 7-230-1-0
SKS-R 7-230
A
SVCD(S) 10-230-1-0
SKS-R 10-230
A
SVCD(S) 13-230-1-0
SKS-R 13-230
B
SVCD(S) 17-230-1-230
SKS-R 17-230
B
SVCD(S) 25-230-1-230
SKS-R 25-230
C
SVCD(S) 40-230-1-230
SKS-R 40-230
C
SVCD(S) 55-230-1-230
SKS-R 55-230
C
SVCD(S) 70-230-1-230
SKS-R 70-230
D
SVCD(S) 85-230-1-230
SKS-R 85-230
D
SVCD(S) 115-230-1-230
SKS-R 115-230
C2
SVCD(S) 145-230-1-230
SKS-R 145-230
C2
Table 3.3.5.1
REVCON
®
- type
Order designation for module
Case type
SVCD(S) 7-400-1-0
SKS-R 7-400
A
SVCD(S) 13-400-1-0
SKS-R 13-400
A
SVCD(S) 18-400-1-0
SKS-R 18-400
A
SVCD(S) 24-400-1-0
SKS-R 24-400
B
SVCD(S) 30-400-1-230
SKS-R 30-400
B
SVCD(S) 50-400-1-230
SKS-R 50-400
C
SVCD(S) 70-400-1-230
SKS-R 70-400
C
SVCD(S) 100-400-1-230
SKS-R 100-400
C
SVCD(S) 125-400-1-230
SKS-R 125-400
D
SVCD(S) 150-400-1-230
SKS-R 150-400
D
SVCD(S) 200-400-1-230
SKS-R 200-400
C2
SVCD(S) 250-400-1-230
SKS-R 250-400
C2
Table 3.3.5.2