background image

 

SAFETY INSTRUCTIONS AND WARNINGS 

 

Do not attempt to use this bathing system without first understanding this manual. 

To ensure safe operation, carefully read this entire manual, especially the section on "Safety Instructions and Warnings", 
before installing, operating, or servicing this equipment. 
 
If anything is not completely understood, please contact  Reval for more details. 
Failure to comply with warnings in this manual may result in injury. 
Keep this manual with the tub and refer to it as required. Contents of this manual are subjected to change without prior 
notice to users. 
 

 

The Transcare bathing system must be installed by a contractor or a certified installation technician.  

 

 

DO NOT open the door when the tub is reclined. 

 

DO NOT open the door if the bath water is above the door seam. 

 

DO NOT immerse the hand control in water. 

 

DO NOT try to lift the tub. 

 

DO NOT stay underneath the tub during lowering. 

 

DO NOT fill over the maximum water level line. 

 

DO NOT operate the air whirlpool pump without water. 

 

DO NOT pull on the shower head too forcibly. 

 

DO NOT place any object underneath the tub. 

 

DO NOT use any electrical appliances near the tub. 

 

DO NOT use any electrical appliances (hair dryer or electric razor, etc) while in the tub. 

 

DO NOT force controls or taps. 

 

DO NOT force the door lock handle. 

 

DO NOT use or turn the disinfection shower on the patient. 

 

 

ALWAYS perform a daily check before using the bathing system. 

 

Each client should be assessed for his or her ambulatory capability to ensure the clients safety when 

     entering and exiting the bathing system. (Ability to utilize handgrips, correct entry height, etc.) 

 

ALWAYS be prepared before transferring a patient into the tub. 

 

ALWAYS rotate the door handle completely to open or close the door. 

 

ALWAYS check the water temperature before the patient enters the tub or to use the cleaning  

     shower. 

 

 

Clean bathtub after each use. 

 

Disinfect bathtub between each use. 

 

All valves should be closed after bathing is completed. 

 

When using disinfectant, wear rubber gloves and eye protection. In case of eye or skin contact, follow the

 

     procedures on the disinfectant container.

 

 

A weekly safety check should be performed to ensure all hoses, pipes, connections and securing devices 

     are in safe working order.  

 

Keep all tub components clean and dry. 

 
 

 
 

 
 
 
 
 
 
 
 

7/21 

Содержание Transcare Series

Страница 1: ...EN Instruction manual ELECTRIC Hi Lo Bathtub Transcare 7203 00 7202 00...

Страница 2: ...TION 10 CLEANING SHOWER VERSION 7202 10 CONCEALED DIGITAL MIXING VALVE RADA SENSE 11 CLEANING SHOWER VERSION 7203 11 DISINFECTION SHOWER VERSION 7202 12 AIR WHIRLPOOL OPTION 13 CHROMOTHERAPY OPTION 14...

Страница 3: ...5 40cm 55cm 8 5 207cm 192cm 120 30cm 3 tilt of footbath 12 tilt of seat 128cm 109cm 124cm 183cm 205cm 47cm 124cm 139cm TUB IN LOW POSITION WITH BASE TUB IN HIGH POSITION WITH BASE 135cm 150cm 83cm 65...

Страница 4: ...lug control Overflow Water temperature display Filling tap Thermostatic mixer Cleaning shower tap Location of the whirlpool control Cleaning shower Overflow max water level 4 functions hand control Ar...

Страница 5: ...OPTIONS HAND CONTROL 4 21 Up Down Recline Upright Filling spout Cleaning shower Plug control Overflow Digital mixing valve RADA SENSE Cleaning shower temperature display Bath fill temerature display...

Страница 6: ...ing valve with built in check valves scald protection and integrated drain stopper Temperature display Cleaning shower Manual draining overflow line 50mm draining plug PLUMBING VERSION 7203 Rada sense...

Страница 7: ...e spout A tap allows to control the water flow The adjustment of the water temperature is made by the thermostatic mixer A digital display allows to check the water temperature A cleaning shower is lo...

Страница 8: ...forcibly DO NOT place any object underneath the tub DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor etc while in the tub DO NOT forc...

Страница 9: ...ers helpful information concerning certain operating procedures _________________________________________________________________________ HIGH LOW FUNCTIONS Raising or lowering the Transcare provides...

Страница 10: ...wn in the photo when properly closed To open the door fully rotate the handle in a clockwise direction until it stops and lift the door up Care should be taken not to let the door fly up on its own Ra...

Страница 11: ...s are designed to prevent an accidental overflow Check the water temperature If necessary adjust it thanks to the mixer Close the drain plug by turning the button in a clockwise direction Turn on the...

Страница 12: ...top water to 10cm approximately below the edge of the tub If the bathtub is equipped with the option automatic stop of filling it is advised to carry out a test of the sensor before the filling see pr...

Страница 13: ...by a flexible going through the top of the venturi white plastic part and 1x disinfection shower head with pawl This set is located behind the front door of the bathtub This door is equipped with a sa...

Страница 14: ...to activate the alternating massage function Massage cycle The massage cycle is 0 30 minutes After 30 minutes the system automatically switches off If the baths water is emptied during the massage cy...

Страница 15: ...following functions On Off Automatically alternate of 7 colours Colour fixed Push one time on the button to turn on the lamps The colours of the lamps automatically alternate during 1 minute for each...

Страница 16: ...matherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bo...

Страница 17: ...or music device 3 On your music device click search for Bluetooth device Make sure you are close enough to the amplifier 4 Select PPGME60 from the pairing list 5 Enter 6000 as the password if required...

Страница 18: ...efreshed after one week CLEANING THE CONTROL PANEL To clean the rada sense control panel take the magnetic key located behind the security door in front of the bath and pass it in front of the infra r...

Страница 19: ...OL SYSTEM For the efficient functioning of the whirlpool system the nozzles have to be cleaned on a regular basis at least once a year Functioning of a whirlpool s nozzle Air is low through the nozzle...

Страница 20: ...NCREASING COMPRESSION OF THE SEAL 1 Have a 5mm Allen key 2 Insert the Allen key into the adjusting screw located inside the door lock 3 Turn the Allen key a quarter of a turn in a clockwise direction...

Страница 21: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Страница 22: ...MAINTENACE FORM LOGBOOK Agent name and signature Corrections Observations Safety parts Control date 21 21...

Страница 23: ...oulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...

Отзывы: