background image

 

DIRECTIONS FOR USE 

 

 

AROMATHERAPY (OPTION) 

 
Reval give all areas of patient well being and safety careful consideration.   Its unique “Aromatherapy” system combines the 
benefits of hydro-massage with the relaxing aromatic effects, of infused aroma essence, providing the ultimate bathing and 
rehabilitation experience.   The “Aromatherapy” system is compressed heated fresh air technology, which infuses aroma 
therapy oils at temperature into the hydrotherapy air jet which explodes into the bath water delivering controlled therapy 
with sensual and relaxing aromas assuring a totally unique and wonderful experience.  Reval's new “Aromatherapy” system 
has an ultra safe auto-clean function which self dries and cleans the internal air ducting pipe work after use automatically.  
The auto-clean function significantly reduces the risk and development of micro -biological organisms that can develop in 
humid and wet environments.   Reval's unique air ducting system can be dismantled without the need for tools and can be 
termically cleaned during routine servicing in a matter of minutes. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TO OPERATE: 

 
1.

 

 Simply remove the chrome cap, take the wooden spatula, soak in aromatherapy oil and replace it in to the essence 
well.  Replace the chrome cap) finger tight).  Do not over tighten! 

2.

 

Switch the Aromatherapy system on via the circular control panel. Once up to temperature the heated air infuses with 
the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bottom of the bath tub.  
The aroma is carried inside the bubbles and explodes on contact with the water releasing the sensual aromatic 
fragrances in to the air.   

3.

 

For extended use switch off and re-soak the spatula as described in points 1&2. 

4.

 

The hydro Aromatherapy has an alternating intensity function.  To activate this potion press the  

̃

 button on the control 

panel.  The intensity will increase and decrease automatically providing needed therapy without sensitivity and 
discomfort for those with sensitive joints and skin conditions. 

5.

 

The intensity can also be set at a fixed pressure for those who enjoy the continuous sensation and work-out.  To fix the 
intensity level simply press the + or – button on the control panel until the desired intensity has been found. 

6.

 

To switch off press the middle button on the control panel marked 1/0. 

7.

 

The Aromatherapy system has a self cleaning function called “Auto Clean”  Once the system has been switched off the 
status LED on the On/Off button changes from ON to Intermittent flashing.  This indicates that the system has gone 
into stand-by mode and will 
Automatically switch on again and run for 5 minutes self drying any build up of humidity in the internal hydro 
plumbing system.  After five minutes the system will shut down. 
 
 

15/21 

 

Содержание Transcare Series

Страница 1: ...EN Instruction manual ELECTRIC Hi Lo Bathtub Transcare 7203 00 7202 00...

Страница 2: ...TION 10 CLEANING SHOWER VERSION 7202 10 CONCEALED DIGITAL MIXING VALVE RADA SENSE 11 CLEANING SHOWER VERSION 7203 11 DISINFECTION SHOWER VERSION 7202 12 AIR WHIRLPOOL OPTION 13 CHROMOTHERAPY OPTION 14...

Страница 3: ...5 40cm 55cm 8 5 207cm 192cm 120 30cm 3 tilt of footbath 12 tilt of seat 128cm 109cm 124cm 183cm 205cm 47cm 124cm 139cm TUB IN LOW POSITION WITH BASE TUB IN HIGH POSITION WITH BASE 135cm 150cm 83cm 65...

Страница 4: ...lug control Overflow Water temperature display Filling tap Thermostatic mixer Cleaning shower tap Location of the whirlpool control Cleaning shower Overflow max water level 4 functions hand control Ar...

Страница 5: ...OPTIONS HAND CONTROL 4 21 Up Down Recline Upright Filling spout Cleaning shower Plug control Overflow Digital mixing valve RADA SENSE Cleaning shower temperature display Bath fill temerature display...

Страница 6: ...ing valve with built in check valves scald protection and integrated drain stopper Temperature display Cleaning shower Manual draining overflow line 50mm draining plug PLUMBING VERSION 7203 Rada sense...

Страница 7: ...e spout A tap allows to control the water flow The adjustment of the water temperature is made by the thermostatic mixer A digital display allows to check the water temperature A cleaning shower is lo...

Страница 8: ...forcibly DO NOT place any object underneath the tub DO NOT use any electrical appliances near the tub DO NOT use any electrical appliances hair dryer or electric razor etc while in the tub DO NOT forc...

Страница 9: ...ers helpful information concerning certain operating procedures _________________________________________________________________________ HIGH LOW FUNCTIONS Raising or lowering the Transcare provides...

Страница 10: ...wn in the photo when properly closed To open the door fully rotate the handle in a clockwise direction until it stops and lift the door up Care should be taken not to let the door fly up on its own Ra...

Страница 11: ...s are designed to prevent an accidental overflow Check the water temperature If necessary adjust it thanks to the mixer Close the drain plug by turning the button in a clockwise direction Turn on the...

Страница 12: ...top water to 10cm approximately below the edge of the tub If the bathtub is equipped with the option automatic stop of filling it is advised to carry out a test of the sensor before the filling see pr...

Страница 13: ...by a flexible going through the top of the venturi white plastic part and 1x disinfection shower head with pawl This set is located behind the front door of the bathtub This door is equipped with a sa...

Страница 14: ...to activate the alternating massage function Massage cycle The massage cycle is 0 30 minutes After 30 minutes the system automatically switches off If the baths water is emptied during the massage cy...

Страница 15: ...following functions On Off Automatically alternate of 7 colours Colour fixed Push one time on the button to turn on the lamps The colours of the lamps automatically alternate during 1 minute for each...

Страница 16: ...matherapy system on via the circular control panel Once up to temperature the heated air infuses with the aroma oil and releases its fragrance into the water via the diffuser jets positioned in the bo...

Страница 17: ...or music device 3 On your music device click search for Bluetooth device Make sure you are close enough to the amplifier 4 Select PPGME60 from the pairing list 5 Enter 6000 as the password if required...

Страница 18: ...efreshed after one week CLEANING THE CONTROL PANEL To clean the rada sense control panel take the magnetic key located behind the security door in front of the bath and pass it in front of the infra r...

Страница 19: ...OL SYSTEM For the efficient functioning of the whirlpool system the nozzles have to be cleaned on a regular basis at least once a year Functioning of a whirlpool s nozzle Air is low through the nozzle...

Страница 20: ...NCREASING COMPRESSION OF THE SEAL 1 Have a 5mm Allen key 2 Insert the Allen key into the adjusting screw located inside the door lock 3 Turn the Allen key a quarter of a turn in a clockwise direction...

Страница 21: ...h should be retained by the person s responsible for the servicing maintenance of the bathtub The date when corrective actions are taken in response to noted observations should also be noted in the l...

Страница 22: ...MAINTENACE FORM LOGBOOK Agent name and signature Corrections Observations Safety parts Control date 21 21...

Страница 23: ...oulle Tel 33 05 46 42 04 16 Fax 33 05 46 43 06 38 www groupe reval com UNITED KINGDOM Reval Continuing Care Limited Unit 17 Brynmenyn Busines Centre St Theodore s Way Brynmenyn CF32 9TZ BRIDGEND WALES...

Отзывы: