21.11.2001
Retsch GmbH
20
Doc. No E98.014-016.9999 A
Intermittent - Continuous operation
Fig. 10
Intermittent operation is initially disabled when the
AS200 is first switched on.
Enable intermittent mode: Fig. 10
* Press
the
R1
button.
* The LED above button
R1
lights.
Disable intermittent mode: Fig. 10
* Press
the
S1
button.
* The LED above button
S1
lights.
Vibration height
If you desire to work with vibration heights above 2.5
mm, we recommend running the AS200 up to this value
slowly. Depending on the loading situation, resonance
(harmonic reinforcement) effects can be induced, causing
the armature and the yoke of the magnet to make contact.
Fig. 11
Setting the vibration height (twice the
amplitude), from 0 to 3.00 mm: Fig. 11
* Turn
the
MN1
knob to the left to reduce the vibration
height, to the right to increase.
The values shown on the potentiometer scale are for
orientation purposes only. There is no absolute
relationship to the actual vibration height and thus this
scale cannot be used as an aid in reproducing previous
values.
Naturally, your AS200 can only achieve the vibration
heights which are within the values shown in the loading
diagram.