54 Hold-o-mat
®
– Operating instructions
Settings (Hold-o-mat 411)
Start the parameter mode = With the unit switched off, press
or
, keep this button
pressed and simultaneously press the main switch. The following then appears in the display:
SET
REAL
68
54
SET
REAL
68
54
CT
23
SET
REAL
110 54
Program 0
Program 1
Program 1
Delta T
>
Language
English
Volume
P. Red
>
TIME
00:10
1
1/3
Time
00:10
Temp
110
Phase 2
CT
53
Temp
80
Phase 3
CT
50
Temp
68
Phase 1
Program 1
Time
00:10
Temp
110
Phase 2
CT
53
Temp
80
Phase 3
CT
50
Temp
68
Phase 1
Scroll through the various parameters with
and
Press button 4 (Program/Enter) briefly
to select the larger parameter in the middle (flashes) and you can now change the value on the right
with Up + Down. This altered value is saved by pressing button 4 again.
Possible parameters and their explanation:
Language
(default = German)
Select the desired language
Volume
(default = 3)
Volume of audio signal (0 – 5)
Powerfail
(default = 5)
– Highest value (in degrees Celsius), which the unit may lose in the event
of a power failure to restart automatically – when power is restored –
and continue with the program.
– If the power is interrupted for longer and the unit loses more than 5 °C,
for example, we have an HACCP quality problem. The unit does not
switch back on and the error message “Power failure” appears.
Autostart
(default = off)
If the unit is to switch on automatically (by means of a timer between the
socket and Hold-o-mat) this parameter has to be switched over to “On”.
Disadvantage: In the event of a power failure overnight, the unit switch-
es back on when the power is restored.
P. Red.
(default = on)
Switches the second temperature sensor (heat sensor) off if this is faulty
but you wish to continue using the Hold-o-mat until the service engineer
can change the sensor.
Содержание Hold-o-mat 411
Страница 22: ...22 Hold o mat Instructions de service ...