Retevis RA26 Скачать руководство пользователя страница 9

11

12

No.

Display

Set Items

Set Parameter Options

Default Value

1

Prompt Tone

 (OFF) /   (ON)

 (ON)

2

Weather Alert

 (OFF) /   (ON)

 (OFF)

3

Priority Scan

 (OFF) /   (ON)

 (OFF)

4

Scan Resume Timer

 (OFF) /   (ON)

 (OFF)

5

Automatic Scan

 (OFF) /   (ON)

 (OFF)

6

Dual/Tri Watch

 - (Dual watch) /   - (Tri watch)

 - (Dual watch)

7

Monitor Key Function

Pu (Push) / Ho (Hold)

Pu (Push)

8

Automatic Backlight

 (OFF) /   (ON)

 (ON)

9

LCD Contrast

Hi / Lo

Hi

10

Automatic Power Save

 (OFF) /   (ON)

On

11

Float Alarm

 (OFF) /   (ON)

 (OFF)

12

Vibration Water Draining

 (OFF) / 2 / 5 / 10 (seconds)

 (OFF)

DUAL/TRI WATCH

 

Description

This radio contains DUAL/TRI WATCH, can be selected in the 

set mode.

Dual watch: 

Watch and monitor in turns between the current 

channel and Channel 16.

Tri watch: 

Watch and monitor in turns among the current 

channel, Channel 16 and CALL Channel.

Dual Watch

Tri Watch

CALL channel

Receive signal during watch and monitor:

• 

Receive signal in Channel 16

Dual/tri watch pause in Channel 16 until the signal disap-

peared.

• 

Receive signal in CALL Channel

Tri watch switches to dual watch until the signal disappeared 

in CALL Channel.

 

Operation

1. 

Hold 

[SCAN/DUAL]

 for 1 second to start dual/tri watch.

• “

DW

” flashes during dual watch; “

TW

” flashes while tri 

watch.

• A “BEEP” sound emits when signal is received in Chan-

nel 16.

• Tri watch switches to dual watch when signal received in 

CALL Channel.

2. 

Press 

[SCAN/DUAL]

 to cancel dual/tri watch.

For example:

 Tri watch in International Channel 01.

Start tri watch.

Receive signal in call

channel 09.

Resume tri watch after

signal disappeared.

Open Channel 16 prior

when signal is received

in Channel 16.

SET MODE

 

Set Mode Operation

The Set Mode can be used to change the settings of the ra-

dio’s function. The function settings including Prompt Tone, 

Weather Alert, Priority Scan, Scan Resume Timer, Auto Scan, 

Dual/Tri Watch, Monitor Key Function, Automatic Backlight, 

LCD Contrast, Power Save, Float Alarm and Vibration Water 

Draining. 

Set mode operation as below.

1. 

ÅÍ»ÈÅŮƔ

2. 

Press and hold 

[VOL/SQL]

, power on to enter set mode.

3. 

Release 

[VOL/SQL]

, LCD appears “

bEEP

”.

4. 

Press 

[VOL/SQL]

 to select desired setting items.

5. 

Press 

[

Y

]

 or 

[

Z

]

 to select desired setting parameter.

6. 

Press 

[C/16]

 to exit set mode.

Содержание RA26

Страница 1: ...Zhonghaixin Science Technology Park No 12 Ganli 6th Road Jihua Street Longgang District Shenzhen China Web www retevis com E mail kam retevis com Facebook facebook com retevis Shenzhen Retevis Techno...

Страница 2: ...me Do not place it in environment or near any heating devices below 20 C or above 55 C Stop using and contact the local dealer if the radio emits strange odor or smoke Do not transmit without antenna...

Страница 3: ...As the LED emergent rescue This function works even the radio is pow Flash Warning Light Alarm Sound Flash Warning Light CONTENTS PREPARATION Standard Accessories 1 Preparation 1 Charging the Battery...

Страница 4: ...cates charging Power Adaptor AC Outlet Charging Port 3 If the battery is full charging LCD appears FL You should remove the adaptor If you do not insert the battery pack while charging the LCD appears...

Страница 5: ...el programming mode While in the set mode press this key to exit VOL SQL MONI Press to enter the volume adjustment mode Press again to enter the squelch adjustment mode Hold for 1 second to active the...

Страница 6: ...ormed within 5 seconds the radio returns to normal mode 2 Press VOL SQL again to exit the volume adjustment mode Adjust the Squelch Level The squelch level can be adjusted through VOL SQL and Y Z Set...

Страница 7: ...l Channel The Call Channel is monitored during tri watch The factory default for Call Chan nel is Channel 9 It can be reprogrammed 1 Press and hold C 16 for 1 5 seconds to select the Call Channel of t...

Страница 8: ...peration is invalid when vibration water draining is activated SCAN OPERATION Scan Types The Scan Types including normal scan and priority scan can be selected in the set mode Please refer to set mode...

Страница 9: ...atch switches to dual watch until the signal disappeared in CALL Channel Operation 1 Hold SCAN DUAL for 1 second to start dual tri watch DW flashes during dual watch TW flashes while tri watch A BEEP...

Страница 10: ...Press and hold MONI the sound emits from loudspeaker Keep holding MONI the loudspeaker con tinuing opened Release MONI the loudspeaker closed Ho HOLD Press and hold MONI for 1 second the sound emits f...

Страница 11: ...00 78A 78A 156 925 156 925 A2 2 162 025 162 025 10 10 10 156 500 156 500 28b RX Only 162 000 79 156 975 161 575 11 11 11 156 550 156 550 60 60 156 025 160 625 79A 79A 156 975 156 975 WX Channel Freque...

Страница 12: ...exposure levels In addition manufacturers also recommend specific operating instructions to users of two way radios These instructions are important because they inform users about RF energy exposure...

Страница 13: ...ical and electronic products batteries and accumulators rechargeable batteries must be taken to designated collection locations at the end of their working life Do not dispose of these products as uns...

Страница 14: ...vice is susceptible to electromagnetic interference EMI if inadequately shielded designed or otherwise configured for electromagnetic compatibility Avoid Choking Hazard Turn off your radio power in th...

Страница 15: ...battery particularly when placing it inside a pocket purse or other container with metal objects Long transmission When the transceiver is used for long transmissions the radiator and chassis will bec...

Отзывы: