Restek Q-sep 3000 Скачать руководство пользователя страница 2

visit 

www.restek.com/QuEChERS

2

Table of Contents

Precautions & Model Description  . . . . . . . . . . 2 

Supplied Equipment  . . . . . . . . . . . . . . . . . . . . . . 3

Available Features  . . . . . . . . . . . . . . . . . . . . . . . . . 3 

Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Control Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 

Setup Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Initial Setup Procedure  . . . . . . . . . . . . . . . . . . . . 5 

Additional Setup Procedure  . . . . . . . . . . . . . . . 6

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 

Tube Holder Configurations  . . . . . . . . . . . . . . . 7 

Balanced Loads  . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 

Care and Preventative Service  . . . . . . . . . . . . . 8 

Rotor Removal and Installation  . . . . . . . . . . . . 9 

Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 

Emergency Rotor Chamber Entry  . . . . . . . . . 10 

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . 11 

Replacement Parts  . . . . . . . . . . . . . . . . . . . . . . . 11 

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Model Description

The Q-sep™ 3000 centrifuge

is a continuous-duty, elec-

tronically-controlled, single speed, horizontal laboratory
centrifuge with a lid safety interlock system. The unit is con-
trolled by an electronic push-button timer that is variable
from 1 to 30 minutes, for precise spin times and ease of use.
Samples can be safely viewed through the transparent lid.
The imbalance detection system safely terminates a run
cycle in the event that a load is severely imbalanced. Entry
into the machine is restricted during operation by the safe-
ty interlock system. The Q-sep™ 3000 centrifuge features a
lighted control panel that displays the status of the
machine, easily viewable from a distance. Finally, a cycle
counter keeps a count of the total number of machine runs
for servicing and maintenance records.

PRECAUTIONS:

1. Do not attempt to unlatch the centrifuge 

lid unless the “Unlocked” indicator light is
illuminated (see pg. 4).  

2. Avoid solvent contact with centrifuge lid.  

3. Insure that the weight load is balanced

before running the centrifuge (see pg. 7).

Quick Start Guide

1.

Choose a well ventilated area for setup.

2.

Plug centrifuge into properly grounded receptacle.

3.

Press “POWER” button (light will illuminate).

4.

Press “OPEN/EMERGENCY STOP” button to disengage locking system and verify that the rotor is not
moving. The “UNLOCKED” light will appear red. It is now safe to open the lid.

5.

Turn latch counter-clockwise to open lid.

6.

Place tube holders in rotor and verify they are seated properly.

7.

Place centrifuge tubes in the tube holders and ensure that the weight load is balanced.

8.

Close lid and turn latch knob clockwise to lock position (“LATCH” indicator light will illuminate).

9.

Press “START” button to initiate operation (“RUN” indicator light will illuminate).

10. Centrifuge will spin for 5 minutes (to adjust spin time, see page 6).
11. When the rotor has come to a full stop, a beeper will sound, the “RUN” indicator will turn off, and the

“UNLOCKED” indicator light will illuminate for 60 seconds. Turn lid knob counter-clockwise to open the
lid and remove samples.

12 If centrifuge locks again before samples are removed, press “OPEN/EMERGENCY STOP” button to disen-

gage locking system. The “UNLOCKED” light will illuminate and the lids can now be opened.

Содержание Q-sep 3000

Страница 1: ...s Service Manual cat 26230 26231 The Q sep 3000 centrifuge complies with all requirements of UL standard 3101 20 Can CSA C22 2 No 1010 1 and Can CSA C22 2 No 1010 2 20 NOTE The programmable run time h...

Страница 2: ...maintenance records PRECAUTIONS 1 Do not attempt to unlatch the centrifuge lid unless the Unlocked indicator light is illuminated see pg 4 2 Avoid solvent contact with centrifuge lid 3 Insure that the...

Страница 3: ...e centrifuge only after the rotor has completely stopped Brushless DC motor requires no routine maintenance cool running Clear lid for safe observation of samples and optical calibration of speed Elec...

Страница 4: ...must be closed Open Emergency Stop Button Allows access to the rotor chamber by disengaging the locking mechanism Entry is only permitted when the rotor is stopped Pressing this button during operati...

Страница 5: ...e cut to the motor but you should not be able to fully turn the latch If it is possible to turn the latch and open the lid while the unit is running contact Restek Corporation or your local distributo...

Страница 6: ...l operation 1 Plug the centrifuge into an approved 115 volt cat 26230 or 230 volt cat 26231 AC 50 60 Hz outlet and press the POWER button 2 Push the OPEN EMERGENCY STOP button verify the rotor is not...

Страница 7: ...perly maintained see Balanced Loads below Balanced Laods Your centrifuge must contain a balanced load in order to work properly To insure that the load is balanced keep these rules in mind when insert...

Страница 8: ...spill occurs in the centrifuge or tube holder thoroughly clean the rotor and both the inside and outside of the tube holder or replace the tube holder if necessary Replacement parts can be found on p...

Страница 9: ...the bottom of the rotor with the pin in the motor shaft see picture The rotor should slide onto the shaft freely and the rotor should be level Be sure that the slot in the underside of the rotor lines...

Страница 10: ...started spinning it may be possible to rotate the lid knob enough to cause the pawl to lose contact with the lid safety switch If this happens the centrifuge motor may lose power but the lid will stil...

Страница 11: ...authorized distributor for assistance The printed circuit board may be damaged Contact Restek Corporation or your distributor for assistance The Q sep 3000 centrifuge is equipped with severe out of ba...

Страница 12: ...and workmanship for 5 000 cycles or 12 months whichever comes first Should the centrifuge require warranty or out of warranty service please contact Restek Corporation or your local distributor Lit C...

Отзывы: