Description of the 

PLT

®

 Solas

By opening the closing valve, air flows from the air cylinder through the 
Reduction Valve and into the chamber of the Base Unit. The pressure in this 
chamber is 75 bars (1088 psi).

Due to heavy recoil, it is important that the PLT

®

 Solas is well supported 

during operation. The rear end of the PLT

®

 Solas Launching Unit has a 

Damper Pad that must be placed against a solid point that can withstands 
this force. See page 9.

The air cylinder must be filled to a minimum of 207 bar (3000 psi) for a 
minimum of 4 launches. With 300 bar (4350 psi) the unit can perform a 
minimum of 6 launches.
The air cylinder refills from a 207/300 bar air compressor for breathing air 
systems. If you are using a 207-bar compressor, the Yoke Adaptor, Art. No. 
1308 is necessary to use.

Launching unit:

Weight/Length

7,5 kg / 65 cm (16.5lb / 25.5 in)

Color 

Orange 

Materials

Anodized Aluminum, Stainless Steel

Chamber Pressure

75 bar (1088 psi)

Estimated Recoil Force

5300 N

Air cylinder:

Pressure

207/300 bar (3000/4350 psi)

Volume

1500 cm3 (91 in3)

Coupling

Standard 5/8” BA-Coupling DIN 477

Practical Information

Contact Information

Restech Norway

Postal Address

P.O. Box 624
N-8001, Bodø (Bodoe)
Norway

Office Number

+47 755 42 440

Visiting Address 

Olav V Gate 112 
8004 Bodø (Bodoe) 
Norway

E-mail

[email protected]

For more information

www.restech.no

Product Certificates

Notifying Body: DNV GL

Type Approval
MED-B Certificate 
Type Approval USCG
Type Approval Transport Canada

4

5

Содержание PLT Solas

Страница 1: ...tenance manual for the PLT Solas This manual should be read before operating the PLT For easy registering the information you need is the serial number for your PLT Solas The serial number is Version...

Страница 2: ...producer and seller cannot be held responsible for damage caused by the PLT Solas if the product is not used according to this manual Always inspect the launching unit rope and projectile before use...

Страница 3: ...lls from a 207 300 bar air compressor for breathing air systems If you are using a 207 bar compressor the Yoke Adaptor Art No 1308 is necessary to use Launching unit Weight Length 7 5 kg 65 cm 16 5lb...

Страница 4: ...ube pointing upwards Insert the projectile into the Launching Tube with the line in the slot of the end plug Fig 4 5 Fasten the end of the line to the line thrower or a secured point Fig 5 6 Aim over...

Страница 5: ...using the Damper Pad on the PLT Solas Air Cylinder Cover For maximum distance hold elevation between 25 to 35 Push and hold the safety knob and aim over the target Pull the trigger with a firm and ra...

Страница 6: ...the chamber of the Launching Unit Annual Check Bring the unit outdoors and fill the chamber with compressed air To reduce the noise you can screw the Launching Tube on the Launching Unit but without...

Страница 7: ...n it is attached to the Launching Unit Do not use excessive force when closing the valve NEVER FILL OXYGEN INTO THE AIR CYLINDER CLEAN AND DRY AIR ONLY Maintenance Procedure of the PLT Air Cylinder In...

Страница 8: ...Restech Norway AS www restech no...

Отзывы: