background image

3. Reconfigure the PIR Detector into Normal

operation mode and refit in position.

Note:  When the detector is fully installed i.e. battery

cover is refitted; the unit will not detect movement

for approximately 45 seconds after each activation.

(This feature is presant to conserve battery power

and maximise the battery life).

MAGNETIC CONTACT 
DETECTOR(S)

The Magnetic Contact Set comprises two parts; a

Detector and a Magnet.  They are designed to be fitted

to either doors or windows with the Magnet screwed

to the moving/opening part and the Contact screwed

to the fixed door or window frame.

When the protected door or window is closed the

Detector Contact Switch is held closed by the Magnetic

field from the Magnet.  Opening the protected door or

window will remove the magnetic field and allow the

Contact Detector Switch to open generating an alarm

signal, (if the system is armed).

The Magnetic Contact Detector has the facility to

connect an additional wired Magnetic Contact.  This

must be of a normally closed contact type with the

contact being opened in order to generate an alarm

condition.

Any number of Magnetic Contact Detectors can be

used with the system, providing they are all coded

with the system House Code and are mounted

within effective radio range of the Solar Siren.

The Magnetic Contact Detector is powered by two

CR2032 type Lithium cells which under normal

conditions will have an expected life in excess of 

1 year.  Under normal battery conditions the LED on

the Detector will not illuminate when the Detector 

s triggered, (unless in test mode).  However, under

low-battery conditions this LED will be illuminated

for approx 1s when the detector is triggered.  When

this occurs the batteries should be replaced as soon

as possible.

POSITIONING THE MAGNETIC
CONTACTS

The Magnetic Contact Detector is suitable for

mounting in dry interior locations only.

Decide which doors and windows are to be protected

by fitting Magnetic Contact Detectors, (usually the

front and back doors as a minimum will have

Magnetic Contact Detectors fitted).  However

additional detectors may be fitted where required 

to other more vulnerable doors or windows, (e.g.

garage, patio/conservatory doors etc).

Ensure that the position selected for the Magnetic

Contact detector is within effective range of the Siren,

(refer to "Testing of Remote Control").

Note:   Take care when fixing the Detector to a metal

frame, or mounting within 1m of metalwork (i.e.

radiators, water pipes, etc) as this could affect the

radio range of the device.  If required, it may be

necessary (under exceptional circumstances) to

space the Magnet and Detector away from the metal

surface using a plastic or wooden spacer to achieve

the necessary radio range.

INSTALLING THE MAGNETIC
CONTACTS

Ensure that the system is in service mode.

1. Remove the battery cover by sliding and lifting it

off.  (DO NOT use a screw driver to lever off).

2. Remove the battery holder by carefully tilting up

the end and pulling the connector off of the printed

circuit board.

3. Mount the Detector to the fixed part of the frame

along the opening edge opposite the hinges

using either the double sided adhesive tape or

screws provided.

12

SA1/SA2/SAC1

Double Sided Tape

OR Screw Fixing

Raised Head Screw,
Key-hole Slot Fixing

Small Counter-sunk
Screw Fixing

Battery

Connector

Tilt and Remove
Battery Holder
and Insert
Two Batteries

Slide Open and Lift Off

Do Not Use A Screwdriver

Содержание SA1 E

Страница 1: ...Installation Operating Manual SA1 SA2 SAC1 Wirefree Alarm Systems 1 4 7 0 2 8 5 6 9 3 LOW BATT ON AIR 2 1...

Страница 2: ...M SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overcome...

Страница 3: ...Positioning the PIR Movement Detectors 9 Installing the PIR Movement Detectors 10 Configuring the PIR Movement Detectors 11 Testing the PIR Movement Detectors 11 MAGNETIC CONTACT DETECTORS 12 Position...

Страница 4: ...ARM SYSTEM The following additional accessories are available to enhance your system and provide further protection and a higher level of security where required Component Product Code Two Magnetic Co...

Страница 5: ...contained in this manual for planning your intruder alarm system Before attempting to install your Alarm System it is important to study your security requirements and plan your installation The alar...

Страница 6: ...ition will suffice Although the Solar Siren is designed to work on any aspect wall for optimum performance you should refrain from siting the unit on a north facing wall where possible Shadows cast by...

Страница 7: ...board This will prevent the Siren from sounding during an alarm condition However the Siren will still beep to acknowledge signals from the Remote Control provided the beep feature is not disabled JA...

Страница 8: ...ck Buttons Tamper Switches etc Service Mode is controlled from the Remote Control refer to page 14 for details REMOTE CONTROL UNIT The Remote Control Unit is used to Arm and Disarm the system The Remo...

Страница 9: ...om in and around the property and from all locations where you plan to install detectors check that the Siren acknowledges the signals from the Remote Control by beeping twice each time the DISARM but...

Страница 10: ...f the Keypad and remove the rear cover 5 Connect the PP3 Alkaline battery to the battery clip 6 Configure the Keypad as described below and then replace the rear cover and fixing screws 7 Refit and se...

Страница 11: ...nowledges the signal by emitting one long beep unless Beep Disable has been set PASSIVE INFRA RED PIR MOVEMENT DETECTORS PIR detectors are designed to detect movement in a protected area by detecting...

Страница 12: ...initiate an alarm Note DO NOT fix the detector to metalwork or locate the unit within 1m of metalwork i e radiators water pipes etc as this could affect the radio range of the Keypad INSTALLING THE PI...

Страница 13: ...hanges e g insects air temperature etc This feature is called Pulse Count and may be selected for 1 or 2 pulse detection The recommended setting is for 1 pulse detection However in cases of extreme en...

Страница 14: ...this LED will be illuminated for approx 1s when the detector is triggered When this occurs the batteries should be replaced as soon as possible POSITIONING THE MAGNETIC CONTACTS The Magnetic Contact D...

Страница 15: ...GNETIC CONTACTS 1 Located in the battery compartment is a row of 11 DIP switches 2 DIP switches 1 8 are used to set the House Code for the Magnetic Contact Detector and must be set to the same ON OFF...

Страница 16: ...buttons on the Keypad for approx 2 3 seconds and ensure that a Full Alarm condition is initiated 12 Stop the Siren and Disarm the system by entering the User Access code followed by the DISARM button...

Страница 17: ...s initiated accidentally the alarm can be stopped immediately by pressing the DISARM button on the Remote Control Arming The System Instant Mode The system can be armed in Instant mode using either th...

Страница 18: ...Access code will revert to the factory default code of 1 2 3 4 when the new battery is connected The User Access code will then need reprogramming as detailed on page 8 PIR Movement Detectors If the v...

Страница 19: ...Before removing the battery cover on any device to replace the battery ensure that the system is put into Test mode to avoid initiating a Full Alarm condition The specifications for replacement batter...

Страница 20: ...minute c Reconnect batteries and then remove Solar panel cover and take out of Service Mode 6 Siren rechargeable battery discharged a Clean Solar Panel b Check age of rechargeable battery replace if...

Страница 21: ...r window is opened 1 Low battery replace Batteries Symptom Recommendation Symptom Recommendation In order to comply with the Code of Practice on Noise from Intruder Alarms 1981 you should carry out th...

Страница 22: ...Detectors Magnetic Contact Sets and Remote Control Units ACCESSORIES SU2 SU1 SU3 20 SA1 SA2 SAC1 SU1 ACCESSORY SET Comprises 2 x Magnetic Contact Sets and 1 x Remote Control Unit SU2 PIR MOVEMENT DETE...

Страница 23: ...interference wilful or accidental damage or any consequential loss or damage howsoever caused This guarantee does not affect your statutory rights and is valid in the UK and Eire only If an item devel...

Страница 24: ...amming Detection Audible confirmation selectable Remote Control RF operating frequency 433MHz Range 50m max Changeable 4 digit User Access code Instant alarm mode 15s Entry Exit Delay alarm mode Anti...

Отзывы: