immediately generate a Full Alarm condition.  On 

returning to and entering the property the system must

be Disarmed before opening any protected door or

entering an area protected by a PIR movement

detector otherwise a Full Alarm condition will occur.

Delay mode will arm the system with a 15 second

entry/exit delay.  On arming the system in Delay mode

there will be a 15 second delay before the system

becomes fully active.  This allows time for you to leave

the property before the system becomes fully active.

On returning to and entering the property by opening

a protected door or moving through a PIR protected

area the system will be triggered and the Siren will

emit a single long beep.  However, a Full Alarm will not

be initiated until the 15 second entry delay has expired

during which time the system should be Disarmed.  If

the system is not Disarmed within the entry delay

period a Full Alarm condition will occur.

If a Full Alarm condition is initiated following an

intrusion and a detector being triggered, (while the

system is armed), the Siren will sound continuously

until the pre-set alarm duration time (1 or 3 minutes)

expires when the siren will cease.  The system will

then immediately automatically reset and re-arm

itself.  In the event that a further detector is triggered

the system will once again initiate a Full Alarm

condition.  This process can be repeated up to three

times after which time the system will not

automatically reset.

If a Full Alarm condition is initiated accidentally the

alarm can be stopped immediately by pressing the

‘DISARM’ button on the Remote Control.

Arming The System Instant Mode

The system can be armed in Instant mode using either

the Remote Control or the Keypad as follows:

Remote Control:

Press the ‘INSTANT-ARM’ button,   

The Siren will acknowledge the signal by beeping

once.

Keypad:

Enter the User Access code followed by the

‘INSTANT-ARM’ button

,    

The Siren will acknowledge the signal by beeping

once.

Arming The System In Delay Mode

The system can be armed in Delay mode using either

the Remote Control or the Keypad as follows:

Remote Control:

Press the ‘DELAY-ARM’ button,  

The Siren will acknowledge the signal by beeping

once and then again after the 15s entry/exit period has

expired.  The system will not be fully armed and active

until after the second beep.

Keypad:

Enter the User Access code followed by followed by

either ‘DELAY-ARM’ button.

,              or

The Siren will acknowledge the signal by beeping

once and then again after the 15s entry/exit period has

expired.  The system will not be fully armed and active

until after the second beep.

DISARMING THE SYSTEM

The system can be Disarmed using either the Remote

Control or the Keypad as follows:

Remote Control:

Press the ‘DISARM’ button,   

The Siren will acknowledge the signal by beeping

twice.

Keypad:

Enter the User Access code followed by the ‘DISARM’

button

,    

The Siren will acknowledge the signal by beeping

twice.

IMPORTANT:  If, when the system is disarmed, the

siren emits a series of ten rapid beeps, this indicates

that a Full Alarm condition has been triggered whilst

the system was armed was armed.  Check the

security of the property before entering.

SA1/SA2/SAC1

15

?

?

?

?

1

2

?

?

?

?

1

?

?

?

?

Содержание SA1 E

Страница 1: ...Installation Operating Manual SA1 SA2 SAC1 Wirefree Alarm Systems 1 4 7 0 2 8 5 6 9 3 LOW BATT ON AIR 2 1...

Страница 2: ...M SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overcome...

Страница 3: ...Positioning the PIR Movement Detectors 9 Installing the PIR Movement Detectors 10 Configuring the PIR Movement Detectors 11 Testing the PIR Movement Detectors 11 MAGNETIC CONTACT DETECTORS 12 Position...

Страница 4: ...ARM SYSTEM The following additional accessories are available to enhance your system and provide further protection and a higher level of security where required Component Product Code Two Magnetic Co...

Страница 5: ...contained in this manual for planning your intruder alarm system Before attempting to install your Alarm System it is important to study your security requirements and plan your installation The alar...

Страница 6: ...ition will suffice Although the Solar Siren is designed to work on any aspect wall for optimum performance you should refrain from siting the unit on a north facing wall where possible Shadows cast by...

Страница 7: ...board This will prevent the Siren from sounding during an alarm condition However the Siren will still beep to acknowledge signals from the Remote Control provided the beep feature is not disabled JA...

Страница 8: ...ck Buttons Tamper Switches etc Service Mode is controlled from the Remote Control refer to page 14 for details REMOTE CONTROL UNIT The Remote Control Unit is used to Arm and Disarm the system The Remo...

Страница 9: ...om in and around the property and from all locations where you plan to install detectors check that the Siren acknowledges the signals from the Remote Control by beeping twice each time the DISARM but...

Страница 10: ...f the Keypad and remove the rear cover 5 Connect the PP3 Alkaline battery to the battery clip 6 Configure the Keypad as described below and then replace the rear cover and fixing screws 7 Refit and se...

Страница 11: ...nowledges the signal by emitting one long beep unless Beep Disable has been set PASSIVE INFRA RED PIR MOVEMENT DETECTORS PIR detectors are designed to detect movement in a protected area by detecting...

Страница 12: ...initiate an alarm Note DO NOT fix the detector to metalwork or locate the unit within 1m of metalwork i e radiators water pipes etc as this could affect the radio range of the Keypad INSTALLING THE PI...

Страница 13: ...hanges e g insects air temperature etc This feature is called Pulse Count and may be selected for 1 or 2 pulse detection The recommended setting is for 1 pulse detection However in cases of extreme en...

Страница 14: ...this LED will be illuminated for approx 1s when the detector is triggered When this occurs the batteries should be replaced as soon as possible POSITIONING THE MAGNETIC CONTACTS The Magnetic Contact D...

Страница 15: ...GNETIC CONTACTS 1 Located in the battery compartment is a row of 11 DIP switches 2 DIP switches 1 8 are used to set the House Code for the Magnetic Contact Detector and must be set to the same ON OFF...

Страница 16: ...buttons on the Keypad for approx 2 3 seconds and ensure that a Full Alarm condition is initiated 12 Stop the Siren and Disarm the system by entering the User Access code followed by the DISARM button...

Страница 17: ...s initiated accidentally the alarm can be stopped immediately by pressing the DISARM button on the Remote Control Arming The System Instant Mode The system can be armed in Instant mode using either th...

Страница 18: ...Access code will revert to the factory default code of 1 2 3 4 when the new battery is connected The User Access code will then need reprogramming as detailed on page 8 PIR Movement Detectors If the v...

Страница 19: ...Before removing the battery cover on any device to replace the battery ensure that the system is put into Test mode to avoid initiating a Full Alarm condition The specifications for replacement batter...

Страница 20: ...minute c Reconnect batteries and then remove Solar panel cover and take out of Service Mode 6 Siren rechargeable battery discharged a Clean Solar Panel b Check age of rechargeable battery replace if...

Страница 21: ...r window is opened 1 Low battery replace Batteries Symptom Recommendation Symptom Recommendation In order to comply with the Code of Practice on Noise from Intruder Alarms 1981 you should carry out th...

Страница 22: ...Detectors Magnetic Contact Sets and Remote Control Units ACCESSORIES SU2 SU1 SU3 20 SA1 SA2 SAC1 SU1 ACCESSORY SET Comprises 2 x Magnetic Contact Sets and 1 x Remote Control Unit SU2 PIR MOVEMENT DETE...

Страница 23: ...interference wilful or accidental damage or any consequential loss or damage howsoever caused This guarantee does not affect your statutory rights and is valid in the UK and Eire only If an item devel...

Страница 24: ...amming Detection Audible confirmation selectable Remote Control RF operating frequency 433MHz Range 50m max Changeable 4 digit User Access code Instant alarm mode 15s Entry Exit Delay alarm mode Anti...

Отзывы: