PART ARMING THE SYSTEM

If you are remaining in the premises, you may Arm

only the PIR Detectors, and Magnetic Contact

Detectors with miniature switches 9 and 10 set to

‘ON’, by selecting ‘Part Arm’.  This will permit free

access to areas where the Detectors are NOT set to

operate on Part Arm.

To Part Arm the system hinge open the keypad cover,

and enter                                             on the keypad, 

then close the keypad cover.

The exit tone emitted when the           button is pressed

will be the same as when fully arming the system 

and is dependant on the setting of miniature switch

number 9 in the Control Unit.  The system will set on

‘Part Arm’ on expiry of the preset exit time.

All occupants must leave any protected areas before

expiry of the exit time.  If for any reason you are unable

to leave the protected areas within the exit time, you

will need to disarm the system then re-arm.  Failure to

do so will cause a Full Alarm if any protected door is

opened or movement is detected by a Passive Infra

Red Detector set to operate in Part Arm.

Note: When set on ‘Part Arm’ the Control Unit top

green light will be flashing. (See page 3).

DISARMING THE SYSTEM

Upon entering the premises or protected area, the

entry tone will be emitted from the control unit sounder

(Continuous or Semi-Silent).

You should proceed immediately to the Control Unit and 

enter                                              to disarm the system.

DISARMING AFTER AN ALARM
ACTIVATION

A Full Alarm condition (Control Unit Siren and External

Siren operating), will be initiated following any intrusion or

Tamper/Personal Attack Activation.  This condition will

continue until expiry of the preset alarm ‘Auto Stop’ time,

whereby the External Siren and Control Unit Siren will

cease.  The Control Unit will now immediately re-arm

itself.  In the event of a further intrusion/activation the

control unit will once again initiate a Full Alarm condition,

and the above process is repeated.

If a Full Alarm condition is initiated accidently, 

the alarm can by stopped immediately by 

entering                                            at the Control Unit.

CONTROL UNIT OFF/ON MODE

To prevent the alarm from being activated when either

opening the Control Unit or removing a battery cover

from a Detector, it is necessary to first enter the Control

Unit OFF/ON code:

The green ‘Power On’ indicator will now extinguish.

When you have completed your alterations, turn the

control unit back ‘ON’ by re-entering the OFF/ON

code as above.  The green ‘Power On’  indicator will

now illuminate and the system is ready for operation.

PERSONAL ATTACK ALARM

A Full Alarm condition can be initiated  by the user at

any time (system armed or disarmed) in the event of

threat or danger.  To initiate an alarm press and hold 

and          buttons on the Control Unit keypad

for more than 2 seconds.

The Control Unit Siren will emit a two tone ‘Tamper’

warning and the External Siren will operate.  To cancel

the alarm enter

at the Control Unit.

BATTERY MONITORING

The system will continuously monitor the battery

condition of all PIR & Magnetic Contact Detectors.  If the

voltage level of any battery falls unacceptably low a radio

signal will automatically be transmitted to the Control

Unit and the yellow ‘Low Battery’ light will flash.

To identify a PIR Detector with a low battery, leave each

protected area for at least 40 seconds. If, when you re-

enter the area the PIR LED flashes on detection of

movement, this indicates a low battery.

The batteries in the Magnetic Contact Detectors can be

checked by operating the Detector (opening and closing

the protected door/window) and observing the LED on

the detector.  If the LED is dim or does not illuminate the

battery needs to be replaced.

Access Code

?

?

?

?

14

Protector P500S

Access Code

?

?

?

?

Access Code

?

?

?

?

Access Code

?

?

?

?

Access Code

?

?

?

?

Содержание Protector P500S

Страница 1: ...Installation Operating Manual Protector P500S Solar Wirefree Alarm System...

Страница 2: ...YSTEM SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overc...

Страница 3: ...rgeable Battery supplied fitted in the External Siren Detector Batteries External Solar Siren Also included Installation Operating Manual All necessary fixings Window stickers EXTENDING YOUR SYSTEM Ha...

Страница 4: ...e protection you can have downstairs plus the garage and shed Part Armed whilst upstairs is Disarmed This allows you to occupy upstairs areas without activating your alarm PLANNING YOUR INSTALLATION B...

Страница 5: ...it will be seen each day INDICATORS AND KEYPAD INDICATOR LIGHTS GREEN On System Fully Armed Flashing System Part Armed Off Disarmed RED On Instant Full Armed Zone Activated Slow flashing Delay Part Ar...

Страница 6: ...when fitting the bottom right hand screw not to damage the ribbon cable and ensure that the control unit sounder plug is plugged into the socket at the bottom right SETTING THE SYSTEM HOUSE CODE In o...

Страница 7: ...gnals However it is possible that it may detect other local radio interference operating legally or illegally on the same frequency If it is planned to operate the jamming detection feature we recomme...

Страница 8: ...only the new Access Code will operate the system Note Do not pause more than 5 seconds between pressing keys otherwise the code change will not be accepted and you will need to start the programming...

Страница 9: ...plied with the entry time preset to 30 seconds However you may change the entry time if required as follows With the Control Unit still in Test mode press then either 10 sec or 20 sec or 30 sec or 40...

Страница 10: ...ts out of areas protected by Passive Infra Red Detectors If this is not possible alternative mounting arrangements or a special Pet Lens may be required 4 Where possible mount the Detector so that the...

Страница 11: ...e Count the more paces an intruder will have to move before triggering the alarm To select the required pulse count move the switch on the side of the detector UP Two Pulse Detection DOWN One Pulse De...

Страница 12: ...nd release the detector anti tamper switch A 3 second two tone alarm will be emitted from the Control Unit Siren This confirms that the House Code is correct 6 If the Magnetic Contact Detector has to...

Страница 13: ...EN The Solar Siren Unit should be fitted to the outside of the building in a position that is clearly visible and at a height which is relatively inaccessible to an intruder The Solar Siren incorporat...

Страница 14: ...ture dip switches 1 8 to a random sequence of ON s and OFF s Make a note of the Siren Code miniature switch settings as this will be needed when setting the siren transmitter in the Control Unit DO NO...

Страница 15: ...out causing unnecessary disturbance OPERATING INSTRUCTIONS FULLY ARMING THE SYSTEM When leaving the premises the system must be Fully Armed However before doing so check that all windows are closed an...

Страница 16: ...of a further intrusion activation the control unit will once again initiate a Full Alarm condition and the above process is repeated If a Full Alarm condition is initiated accidently the alarm can by...

Страница 17: ...arm Activated light MAINTENANCE Your P500S Intruder Alarm system requires very little maintenance However a few simple tasks will ensure its continued reliability and operation CONTROL UNIT The Contro...

Страница 18: ...maintenance during this period providing the batteries are kept charged The batteries will be damaged if stored in a discharged state The rechargeable batteries should be taken to a suitable Recycling...

Страница 19: ...een keys 2 Incorrect code entered Allow 5 seconds to elapse before re entering correct code 3 Unit has reset to Access Code 1 2 3 4 Re programme your Access Code Control Unit not responding to detecto...

Страница 20: ...with correct polarity 2 Replace batteries with new 3 Ensure battery connections are good and that connector is fitted correctly to PCB Magnetic Contact Detector false alarming 1 Ensure that gap betwee...

Страница 21: ...your Alarm System REPEATER UNIT CA2000RU The signal distance range between a detector and the Control Unit is typically up to 100m in free air space If you need to increase this range just place the R...

Страница 22: ...e packaging with 1 A copy of your original invoice receipt 2 A full description of the fault 3 All relevant batteries PLEASE NOTE If returning a Control Unit make sure that the optional rechargeable b...

Страница 23: ...Door or window mounting Low battery indicator Lithium batteries supplied Wirefree Passive Infra Red Detector Detection range up to 6 metres at 110 and 12 metres at 60 Walk test facility One or two pu...

Отзывы: