background image

necessary to space the Magnet/Detector off the

metal surface using a plastic or wooden spacer to

achieve the necessary radio range.

8. Remove the battery holder, then using the double

sided tape OR  the screws provided, mount the

Magnet to the door and the Detector to the door

frame (or vice-versa, if necessary).  Ensure that the

arrows on the Magnet and Detector are pointing

towards each other and that the gap between the

Detector and Magnet is less than 5 mm.  When

using the screws for mounting the Detector, ensure

that the small countersunk screw is used within the

battery compartment and that the screw is driven

flush with the inside of the casing.

9. Refit the battery holder (the Control Unit will emit a

3 second Tamper Alarm).

10. Refit the battery cover by placing it over the

batteries and sliding it on.

11. Test the operation by opening the door/window.

The LED on the Detector will light for approximately

1 second and then extinguish each time the

Magnet is moved away from the Detector, and the

Control Unit will emit a 3 second alarm tone each

time the Detector is operated.

When you have completed installing all your

Detectors, take the Control Unit out of Test mode

by entering

at the Control Unit.

EXTERNAL SOLAR SIREN

The Solar Siren Unit should be fitted to the outside of

the building in a position that is clearly visible and  at a

height which is relatively inaccessible to an intruder.

The Solar Siren incorporates a solar panel which will

maintain a charge to the integral 6 Volt 1.2Ahr sealed

lead acid rechargeable battery during daylight hours.

During the night, a negligible amount of energy is

released by the rechargeable battery to operate the

Siren.  The Solar Siren is self maintainable during

darkness and long winter periods.

LOCATION

To  provide the optimum amount on daylight to the 

Solar Panel, you should ideally mount the Solar Siren 

on a south facing wall.  However, an easterly or

westerly position will suffice.

Although the Solar Siren is designed to work on any

aspect wall, for optimum performance you should

refrain from siting the Unit on a north facing wall

where possible.  Shadows cast by neighbouring

walls, trees and roof overhangs should also be

avoided.  Where applicable, the Solar Siren should be

positioned a minimum of twice the width of the eaves

overhang below the eaves.  Remember that in winter

the sun is lower in the sky and you should avoid

winter shadows where possible.

The Solar Siren contains a sophisticated radio receiver.

However, reception of radio signals can be affected by

the presence of metallic objects within the vicinity of 

Access Code

?

?

?

?

Protector P500S

11

NORTH

WEST

EAST

SOUTH

Avoid if
possible

Содержание Protector P500S

Страница 1: ...Installation Operating Manual Protector P500S Solar Wirefree Alarm System...

Страница 2: ...YSTEM SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overc...

Страница 3: ...rgeable Battery supplied fitted in the External Siren Detector Batteries External Solar Siren Also included Installation Operating Manual All necessary fixings Window stickers EXTENDING YOUR SYSTEM Ha...

Страница 4: ...e protection you can have downstairs plus the garage and shed Part Armed whilst upstairs is Disarmed This allows you to occupy upstairs areas without activating your alarm PLANNING YOUR INSTALLATION B...

Страница 5: ...it will be seen each day INDICATORS AND KEYPAD INDICATOR LIGHTS GREEN On System Fully Armed Flashing System Part Armed Off Disarmed RED On Instant Full Armed Zone Activated Slow flashing Delay Part Ar...

Страница 6: ...when fitting the bottom right hand screw not to damage the ribbon cable and ensure that the control unit sounder plug is plugged into the socket at the bottom right SETTING THE SYSTEM HOUSE CODE In o...

Страница 7: ...gnals However it is possible that it may detect other local radio interference operating legally or illegally on the same frequency If it is planned to operate the jamming detection feature we recomme...

Страница 8: ...only the new Access Code will operate the system Note Do not pause more than 5 seconds between pressing keys otherwise the code change will not be accepted and you will need to start the programming...

Страница 9: ...plied with the entry time preset to 30 seconds However you may change the entry time if required as follows With the Control Unit still in Test mode press then either 10 sec or 20 sec or 30 sec or 40...

Страница 10: ...ts out of areas protected by Passive Infra Red Detectors If this is not possible alternative mounting arrangements or a special Pet Lens may be required 4 Where possible mount the Detector so that the...

Страница 11: ...e Count the more paces an intruder will have to move before triggering the alarm To select the required pulse count move the switch on the side of the detector UP Two Pulse Detection DOWN One Pulse De...

Страница 12: ...nd release the detector anti tamper switch A 3 second two tone alarm will be emitted from the Control Unit Siren This confirms that the House Code is correct 6 If the Magnetic Contact Detector has to...

Страница 13: ...EN The Solar Siren Unit should be fitted to the outside of the building in a position that is clearly visible and at a height which is relatively inaccessible to an intruder The Solar Siren incorporat...

Страница 14: ...ture dip switches 1 8 to a random sequence of ON s and OFF s Make a note of the Siren Code miniature switch settings as this will be needed when setting the siren transmitter in the Control Unit DO NO...

Страница 15: ...out causing unnecessary disturbance OPERATING INSTRUCTIONS FULLY ARMING THE SYSTEM When leaving the premises the system must be Fully Armed However before doing so check that all windows are closed an...

Страница 16: ...of a further intrusion activation the control unit will once again initiate a Full Alarm condition and the above process is repeated If a Full Alarm condition is initiated accidently the alarm can by...

Страница 17: ...arm Activated light MAINTENANCE Your P500S Intruder Alarm system requires very little maintenance However a few simple tasks will ensure its continued reliability and operation CONTROL UNIT The Contro...

Страница 18: ...maintenance during this period providing the batteries are kept charged The batteries will be damaged if stored in a discharged state The rechargeable batteries should be taken to a suitable Recycling...

Страница 19: ...een keys 2 Incorrect code entered Allow 5 seconds to elapse before re entering correct code 3 Unit has reset to Access Code 1 2 3 4 Re programme your Access Code Control Unit not responding to detecto...

Страница 20: ...with correct polarity 2 Replace batteries with new 3 Ensure battery connections are good and that connector is fitted correctly to PCB Magnetic Contact Detector false alarming 1 Ensure that gap betwee...

Страница 21: ...your Alarm System REPEATER UNIT CA2000RU The signal distance range between a detector and the Control Unit is typically up to 100m in free air space If you need to increase this range just place the R...

Страница 22: ...e packaging with 1 A copy of your original invoice receipt 2 A full description of the fault 3 All relevant batteries PLEASE NOTE If returning a Control Unit make sure that the optional rechargeable b...

Страница 23: ...Door or window mounting Low battery indicator Lithium batteries supplied Wirefree Passive Infra Red Detector Detection range up to 6 metres at 110 and 12 metres at 60 Walk test facility One or two pu...

Отзывы: