INTRODUCTION

The Protector P500S Alarm System contains all

components necessary to install a complete system.

Items included are:

1 x Control Unit

1 x D.C. Mains Adaptor

2 x Wirefree Passive Infra Red Detectors

2 x Wirefree Magnetic Contact Detectors

1 x External Solar Siren

1

Protector P500S

WP1.2-6

Wirefree Passive Infra

Red Detectors (PIR’s)

DC Mains Adaptor

Control Unit

(optional back-up battery NOT included).

Wirefree Magnetic

Contact Detectors 

Rechargeable Battery

(supplied fitted in the External Siren)

Detector Batteries

External Solar Siren

Also included:

Installation & Operating Manual

All necessary fixings

Window stickers

EXTENDING YOUR SYSTEM

Having selected a Protector Wirefree Alarm System, you can

increase your protection by adding additional Wirefree Passive

Infra Red Detectors (PIR’s) or Wirefree Magnetic Contact

Detectors, either at  the time of initial installation or at a future

date.  Full details of other accessories to extend your system

are given on page 19.  You may also wish to purchase Remote

Control Unit(s) to enable you to operate your Control Unit from

in or around your premises.

Содержание Protector P500S

Страница 1: ...Installation Operating Manual Protector P500S Solar Wirefree Alarm System...

Страница 2: ...YSTEM SECURITY This system has been designed to both detect intruders and act as a strong deterrent to would be intruders Please remember that given adequate knowledge and time it is possible to overc...

Страница 3: ...rgeable Battery supplied fitted in the External Siren Detector Batteries External Solar Siren Also included Installation Operating Manual All necessary fixings Window stickers EXTENDING YOUR SYSTEM Ha...

Страница 4: ...e protection you can have downstairs plus the garage and shed Part Armed whilst upstairs is Disarmed This allows you to occupy upstairs areas without activating your alarm PLANNING YOUR INSTALLATION B...

Страница 5: ...it will be seen each day INDICATORS AND KEYPAD INDICATOR LIGHTS GREEN On System Fully Armed Flashing System Part Armed Off Disarmed RED On Instant Full Armed Zone Activated Slow flashing Delay Part Ar...

Страница 6: ...when fitting the bottom right hand screw not to damage the ribbon cable and ensure that the control unit sounder plug is plugged into the socket at the bottom right SETTING THE SYSTEM HOUSE CODE In o...

Страница 7: ...gnals However it is possible that it may detect other local radio interference operating legally or illegally on the same frequency If it is planned to operate the jamming detection feature we recomme...

Страница 8: ...only the new Access Code will operate the system Note Do not pause more than 5 seconds between pressing keys otherwise the code change will not be accepted and you will need to start the programming...

Страница 9: ...plied with the entry time preset to 30 seconds However you may change the entry time if required as follows With the Control Unit still in Test mode press then either 10 sec or 20 sec or 30 sec or 40...

Страница 10: ...ts out of areas protected by Passive Infra Red Detectors If this is not possible alternative mounting arrangements or a special Pet Lens may be required 4 Where possible mount the Detector so that the...

Страница 11: ...e Count the more paces an intruder will have to move before triggering the alarm To select the required pulse count move the switch on the side of the detector UP Two Pulse Detection DOWN One Pulse De...

Страница 12: ...nd release the detector anti tamper switch A 3 second two tone alarm will be emitted from the Control Unit Siren This confirms that the House Code is correct 6 If the Magnetic Contact Detector has to...

Страница 13: ...EN The Solar Siren Unit should be fitted to the outside of the building in a position that is clearly visible and at a height which is relatively inaccessible to an intruder The Solar Siren incorporat...

Страница 14: ...ture dip switches 1 8 to a random sequence of ON s and OFF s Make a note of the Siren Code miniature switch settings as this will be needed when setting the siren transmitter in the Control Unit DO NO...

Страница 15: ...out causing unnecessary disturbance OPERATING INSTRUCTIONS FULLY ARMING THE SYSTEM When leaving the premises the system must be Fully Armed However before doing so check that all windows are closed an...

Страница 16: ...of a further intrusion activation the control unit will once again initiate a Full Alarm condition and the above process is repeated If a Full Alarm condition is initiated accidently the alarm can by...

Страница 17: ...arm Activated light MAINTENANCE Your P500S Intruder Alarm system requires very little maintenance However a few simple tasks will ensure its continued reliability and operation CONTROL UNIT The Contro...

Страница 18: ...maintenance during this period providing the batteries are kept charged The batteries will be damaged if stored in a discharged state The rechargeable batteries should be taken to a suitable Recycling...

Страница 19: ...een keys 2 Incorrect code entered Allow 5 seconds to elapse before re entering correct code 3 Unit has reset to Access Code 1 2 3 4 Re programme your Access Code Control Unit not responding to detecto...

Страница 20: ...with correct polarity 2 Replace batteries with new 3 Ensure battery connections are good and that connector is fitted correctly to PCB Magnetic Contact Detector false alarming 1 Ensure that gap betwee...

Страница 21: ...your Alarm System REPEATER UNIT CA2000RU The signal distance range between a detector and the Control Unit is typically up to 100m in free air space If you need to increase this range just place the R...

Страница 22: ...e packaging with 1 A copy of your original invoice receipt 2 A full description of the fault 3 All relevant batteries PLEASE NOTE If returning a Control Unit make sure that the optional rechargeable b...

Страница 23: ...Door or window mounting Low battery indicator Lithium batteries supplied Wirefree Passive Infra Red Detector Detection range up to 6 metres at 110 and 12 metres at 60 Walk test facility One or two pu...