Table of Contents

Section 1- Special Notes

  

Warnings 

  

Cautions

  

Radio Frequency Interference

  

Intended Use

Section 2- Packaging And Handling

  

Unpacking

  

Accessory List  

     

    

Inspection

  

Storage

Section 3- Features

  

Parts and Functions

  

Circuit Diagram

Section 4- Device Technical Indicators

Section 5- Operating Instructions

  

Introduction 

  

Product Functions 

  
  

Operating

 

Pandl

 

and

 

LCD Screen

  

Operating

 

Medthod

Start to use

Section 6- Cleaning And Maintenance 

  

Cleaning and Maintenance 

  

Warranty Instructions

Section 7- Troubleshooting Guide

  

Troubleshooting

  

Alarms

Appendix A : EMC Information

04

04

05

06

06

07

07

07

07

07

08

08

09

10

11

11

11

11

13

14

15

15

15

16

16

17

18

Drip Proof Equipment

IP21

NO smoking

Serial Number

Indicating its conformity with the medical devices 
directive 93/42/EEC.
The 0917 is the number of notified body.

Proper disposal of equipment according to 
local 

 

laws and regulations.

Type BF Applied Part

Class 

Ⅱ(

Double Insulated

Maufacturer

European authorized representative

Read instructions before use

Caution,consult accompanying documents

European RoSH

Date of manufacture

03

02

Respiratory Medical Solutions

 

EC     REP

SN

Содержание AO3 Series

Страница 1: ...piratory equipment www rms care com EC REP Part NO 233010002 Rev 3 0 3 20 15 Manufacture Shenyang RMS Medical Tech Co Ltd Address No 8 1 Gaoge Road Hunnan New District Shenyang China Tel 0086 024 23782895 8001 Fax 0086 024 23782895 8008 KINGSMEAD SERVICE LIMITED 145 157 St John Street London EC1V 4PY UK TEL 044 20 7193 9159 ...

Страница 2: ...e Warranty Instructions Section 7 Troubleshooting Guide Troubleshooting Alarms Appendix A EMC Information 04 04 05 06 06 07 07 07 07 07 08 08 09 10 11 11 11 11 13 14 15 15 15 16 16 17 18 Drip Proof Equipment IP21 NO smoking Serial Number Indicating its conformity with the medical devices directive 93 42 EEC The 0917 is the number of notified body Proper disposal of equipment according to local law...

Страница 3: ...ction 1 Special Notes Please read all instructions before using Important information is highlighted by these terms 1 1 Warnings Never use aerosol sprays or flammable anesthetics near the equipment If the equipment has a damaged cord or plug if it is not working properly if it has been dropped or damaged or if it has been submersed in water do not use and call a qualified technician for examinatio...

Страница 4: ...ency so it may cause interference if using the portable communication equipments near the device 1 4 Intended Use Medical oxygen concentrator Model AO3 AO3W AO5 AO5W used for separating oxygen from air EUT not intended to be used for emergency treatment and patient who has serious carbon monoxide poisoning cannot use this device Section 2 Packaging And Handling 2 1 Unpacking Check for any obvious ...

Страница 5: ...test Oxygen Concentration Testing Circuit Breaker Power Switch Power Socket Filter Device Tag LCD Screen Control Buttons Caste Handle Warning Tag Oxygen Outlet Inlet Filter Window Compressed Air Output Humidifier Bottle Section 3 Features 3 1 Parts and Functions Flow Regulating Button Filter Oxygen Outlet Control Buttons Respiratory Medical Solutions 09 08 ...

Страница 6: ...backpressure is 0 and the rated flow is 3L min giving a 7kpa backpressure can make the flow being 2 8 L min If the power network isn t stable the power voltage fluctuate over 10 please use it after installing a voltage stabilizer Make sure the environment nearby dry ventilated no dust and any other caustic gas no strong electromagnetic interference This device can be used normally below the height...

Страница 7: ...en tube and check the power cord using it continuously after troubleshooting Press On Off button to use it continuously after the external power regaining End of use Press the On Off button to stop the device working after finished using and turn off the power cord Take down the power line if you don t often use it 5 4 Operating Panel and LCD Screen Start Stop Plus Key Minus Key Timer Key Mode Oxy...

Страница 8: ...e The damage caused by human error fault operation konck moving liquid infiltration etc The damage by natural disasters or accidents Other accessories not listed for warranty Oxygen Concentration 0 1 2 3 4 This time 00 00 h min Timer off h min Flow L min 5 5 Operating Method Operation interface Display working mode alarm information oxygen concentration oxygen flow present service time timing time...

Страница 9: ...ndicator flashing Continuous Alarm Concentrator not operating Press start stop the alarm stops Call service provider indicator flashing Continuous Alarm start stop the alarm stops Call service provider Concentrator not operating The red low pressure indicator flashing Continuous Alarm Press start stop the alarm stops Call service provider Concentrator not operating The red hign pressure indicator ...

Страница 10: ...3 3 Vrms 150 kHz to 80 MHZ outside ISM bandsa 3 V m 80 MHz to 2 5 GHz 3V 3V m Portable and mobile RF communications equipment should be used no closer to any part of the XXXXXXX including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Guidance and manufacturer s declaration electromagnetic immunity This device is intended...

Отзывы: