Mercury 2 & Intuitive Mobile Controller User Guide

 

 

www.resourcedm.com 

Example of resistor fitted on a probe input. 

 

 

Inputs 

Input resistance: 

 

3.01K Ohms (for PTC or NTC type probes) 

Input type  

 

Selectable. See: 

Units

 

 
Comms:   

 

RS232 with flow control 

 
 

Switched Resistor Example Wiring 

 
 

 

 

Installation 

 

Panel Cut-out and Clearances 
 
Mercury Mk2 (Flush mount controller) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Dimensions 

 

Mercury Mk2 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fixing 

The controller is fixed by sliding the 2  plastic retaining 
clips up to rear of the panel. These clips have a ratchet 
action and can be removed by holding in the clip sides 
and sliding back. 
 
There is no requirement for forced cooling ventilation

 

 
 

Connect to remote switch or relay 

Probe Ground 

Probe Signal 

 

Содержание PR0710-MOB

Страница 1: ...rce Data Management Ltd 80 Johnstone Avenue Hillington Industrial Estate Glasgow Scotland G52 4NZ UK 44 0 141 810 2828 sales resourcedm com US OFFICE Resource Data Management Inc 100 North Sixth Stree...

Страница 2: ...e achieved at the network front end 8 Unit Set view temperature unit and Probe type 8 Display 9 Parameter Tables 9 Parameter Descriptions 10 Relay State and functional operation 12 Relay and screen st...

Страница 3: ...Ensure that all power is switched off before installing or maintaining this product Mercury 2 Intuitive Mobile Controller User Guide www resourcedm com Fixing 19 Dimensions 20 Intuitive Mercury Mount...

Страница 4: ...B Intuitive Mercury Single or Twin Compressor Controller integral display PR0750 MOB Intuitive Mercury Single or Twin Compressor Controller remote display PR0760 MOB Intuitive Mercury Single or Twin C...

Страница 5: ...tuitive Mercury display is Green in colour when lit Connections Mercury Mk2 6 5E and 6 5M Enter Up Down Defrost Note Function keys illuminate when pressed illumination is turned off 20 seconds after t...

Страница 6: ...scription RS232 IP IP Interface RS485 RS485 Interface IP Network Card PR0770 Rotary Address Switches Network Collision LED Network Activity LED Network Expansion Port The Intuitive Mercury is supplied...

Страница 7: ...0 25W For improved accuracy whilst using switched resistors RDM recommend resistors with 0 1 accuracy are used Note the switched resistor features will not function when using 470R or 700R probes Whe...

Страница 8: ...meter list below to find what parameter number corresponds to which actual parameter Pressing the Enter button will show the current value of the selected parameter Press Up or Down to modify the valu...

Страница 9: ...to 86 0 1 Deg 10 14 8 46 4 P 15 Probe 5 Select 0 Defrost 1 Monitor 1 0 0 P 16 Relay 3 Mode 0 Lights 1 Alarm 1 0 0 P 29 Probe 3 Resistor function 0 Plant fault 1 External defrost 1 0 0 P 18 Service In...

Страница 10: ...scription P 01 Cut in Temp Temperature at which the lead compressor will switch on P 02 Diff Differential temperature below the cut in temperature The lead compressor switches off when below this temp...

Страница 11: ...harge probe exceeds this value and P 30 and P 31 are set to ON then the relevant compressor will be disabled P 33 Discharge Stop Differential This is the differential below the discharge stop value th...

Страница 12: ...remote command from the front end starts the recovery process P 95 Defrost Skip Allows user to enable disable defrost skip This feature allows the controller to skip defrosts If the current defrost t...

Страница 13: ...ed as on during defrost Network Configuration The final section to setup is the network address In all instances this must be done before the controller is plugged into the site network The controller...

Страница 14: ...mation if the network type is set to Genus compatible Press the Enter button to execute the command Up or Down buttons to cancel If the network type is not set to Genus compatible then the ClrA messag...

Страница 15: ...255 192 0 18 255 192 0 0 10 255 255 255 128 25 255 255 128 0 17 255 128 0 0 09 255 255 255 0 24 255 255 0 0 16 255 0 0 0 08 Mercury Switch Please refer to the Mercury Switch user guide which can be o...

Страница 16: ...ton presses The top bar of the left hand segment will be lit when the maximum temperature is being displayed The bottom bar of the left hand segment will be lit when the minimum temperature is being d...

Страница 17: ...Lights Only state if the current state is not Lights Only If the current state is Lights Only then the controller will change to the Normal state Selecting this option will exit the setup menu automat...

Страница 18: ...no requirement for forced cooling ventilation There is no requirement for forced cooling ventilation Class 2 Insulation No protective Earth is required and none should be fitted No protective Earth is...

Страница 19: ...Input type Selectable See Units Comms RS232 with flow control Switched Resistor Example Wiring Installation Panel Cut out and Clearances Mercury Mk2 Flush mount controller Dimensions Mercury Mk2 Fixin...

Страница 20: ...ch clip until it clicks to remove the controller Each clip has a mounting hole to provide an alternative fixing mechanism to DIN mounting Cleaning Do not wet the controller when cleaning Clean the fro...

Страница 21: ...ore installing or maintaining this product Mercury 2 Intuitive Mobile Controller User Guide www resourcedm com Revision History Revision Date Changes 1 0 23 01 2014 First Issue 1 1 29 01 2014 Maximum...

Отзывы: