background image

 

 

 

Revision 1.1 

Page 18 of 21 

 

 

 

Warning 

 
 
 
 
 
 

Please Note 

The specifications of the product detailed on this 
Set-Up  Guide  may  change  without  notice.  RDM 
Ltd. shall not be liable for errors or for incidental 
or consequential damages, directly and indirectly, 
in connection with the furnishing, performance or 
misuse of this product or document.

 

Ensure that all power is 
switched off before   
installing or maintaining 
this product 

Mercury 2 & Intuitive Mobile Controller User Guide

 

 

www.resourcedm.com 

Specification 

 
 

 

     

 
   Warning: Relay 5 output has hazardous voltages (Supply input voltage potential) 
This does not apply to the Intuitive Mercury controller 

 
 

 

 

 

 

Mercury Mk2 Controller 

PR0710-MOB & PR0720-MOB

 

Intuitive Mercury controller 

PR0750-MOB & PR0760-MOB

 

Power requirements 

 

 

 

 

 

Supply Voltage Range

 

100 - 240 Vac ±10%

 

100 - 240 Vac ±10%

 

Supply Frequency

 

50 - 60 Hz

 

50 - 60 Hz

 

Maximum supply current

 

5.2 Amps (when relay 5 is fully loaded)

 

2 Amps 

Typical supply current

 

<1 Amp

 

<1 Amp

 

 

 

 

General 

 

 

Operating temperature range

 

+5

0

C to +50

0

C

 

+5

0

C to +50

0

C

 

Storage temperature range 

-20

0

C to +65

0

-20

0

C to +65

0

Environmental 

Indoor use at altitudes up to 2000m, pollution 

degree 1, installation category II. Voltage 

fluctuations not to exceed ±10% of nominal 

voltage. 

Indoor use at altitudes up to 2000m, pollution 

degree 1, installation category II. Voltage 

fluctuations not to exceed ±10% of nominal 

voltage. 

Size 

78mm (W) x 36mm (H) x 110mm (D) 

157mm (W) x 67mm (H) x 120 (D) 

Approx Weight 

170 grams 

500 grams 

Safety 

EN61010 

EN61010 

EMC 

EN61326; 1997 +Amdt. A1; 1998 

EN61326; 1997 +Amdt. A1; 1998 

Ventilation 

There is no requirement for forced cooling 

ventilation 

There is no requirement for forced cooling 

ventilation 

Class 2 Insulation 

No

 protective Earth is required and 

none 

should be fitted 

No

 protective Earth is required and 

none 

should 

be fitted 

Supply Fuse 

The host equipment must provide a suitable 
external over-current protection device such 

as: - 

Fuse: 6.3A 240 Vac Antisurge (T) HRC 

conforming to IEC 60127

 

Built in fuse holder, fuse 2A 240Vac Antisurge (T) 

HRC conforming to IEC60127, 32 x 6.3mm 

 

Or MCB 
 

6A, 240 VAC Type C conforming to BS EN 

60898 

2A, 240 VAC Type C conforming to BS EN 60898 

(Note: controller has integral 2A fuse) 

Relay Fuse 

Not Fitted 

10A 240Vac Antisurge (T) HRC conforming to 

IEC60127, 32 x 6.3mm 

 

 

 

 

Relay Specification 

 

 

 

 

 

Relays 1-4 Mechanical Type (M) 
Exclusive common

 

 

 

Max current 

6A Resistive (CosØ = 1) 

2A Inductive ( CosØ = 0.4) 

10A Resistive (CosØ = 1) 

3A Inductive ( CosØ = 0.4) 

Max voltage 

250Vac, 30V dc 

250Vac. 30V dc 

Relay Fuse 

N/A 

10A 240Vac Antisurge (T) HRC conforming to 

IEC60127, 32 x 6.3mm 

 

 

 

Relay 5 Mechanical Type (M) 
Common connected to supply 
live

 

 

Relay 5 Mechanical Type (M) 

Exclusive common

 

 

 

 

Max current

 

3A (non inductive), COS

=0.4 2A (inductive 

load) 200,000 operations 

10A Resistive (CosØ = 1) 

3A Inductive ( CosØ = 0.4) 

Max voltage 

250Vac (Internal supply) 

250Vac. 30V dc (external supply) 

 

For compliance with the LVD, relays 3, 4 and 5 
commons must be at the same potential as the 

supply voltage 

All relays are independent and can operate at 

different potentials to the supply voltage. 

Содержание PR0710-MOB

Страница 1: ...rce Data Management Ltd 80 Johnstone Avenue Hillington Industrial Estate Glasgow Scotland G52 4NZ UK 44 0 141 810 2828 sales resourcedm com US OFFICE Resource Data Management Inc 100 North Sixth Stree...

Страница 2: ...e achieved at the network front end 8 Unit Set view temperature unit and Probe type 8 Display 9 Parameter Tables 9 Parameter Descriptions 10 Relay State and functional operation 12 Relay and screen st...

Страница 3: ...Ensure that all power is switched off before installing or maintaining this product Mercury 2 Intuitive Mobile Controller User Guide www resourcedm com Fixing 19 Dimensions 20 Intuitive Mercury Mount...

Страница 4: ...B Intuitive Mercury Single or Twin Compressor Controller integral display PR0750 MOB Intuitive Mercury Single or Twin Compressor Controller remote display PR0760 MOB Intuitive Mercury Single or Twin C...

Страница 5: ...tuitive Mercury display is Green in colour when lit Connections Mercury Mk2 6 5E and 6 5M Enter Up Down Defrost Note Function keys illuminate when pressed illumination is turned off 20 seconds after t...

Страница 6: ...scription RS232 IP IP Interface RS485 RS485 Interface IP Network Card PR0770 Rotary Address Switches Network Collision LED Network Activity LED Network Expansion Port The Intuitive Mercury is supplied...

Страница 7: ...0 25W For improved accuracy whilst using switched resistors RDM recommend resistors with 0 1 accuracy are used Note the switched resistor features will not function when using 470R or 700R probes Whe...

Страница 8: ...meter list below to find what parameter number corresponds to which actual parameter Pressing the Enter button will show the current value of the selected parameter Press Up or Down to modify the valu...

Страница 9: ...to 86 0 1 Deg 10 14 8 46 4 P 15 Probe 5 Select 0 Defrost 1 Monitor 1 0 0 P 16 Relay 3 Mode 0 Lights 1 Alarm 1 0 0 P 29 Probe 3 Resistor function 0 Plant fault 1 External defrost 1 0 0 P 18 Service In...

Страница 10: ...scription P 01 Cut in Temp Temperature at which the lead compressor will switch on P 02 Diff Differential temperature below the cut in temperature The lead compressor switches off when below this temp...

Страница 11: ...harge probe exceeds this value and P 30 and P 31 are set to ON then the relevant compressor will be disabled P 33 Discharge Stop Differential This is the differential below the discharge stop value th...

Страница 12: ...remote command from the front end starts the recovery process P 95 Defrost Skip Allows user to enable disable defrost skip This feature allows the controller to skip defrosts If the current defrost t...

Страница 13: ...ed as on during defrost Network Configuration The final section to setup is the network address In all instances this must be done before the controller is plugged into the site network The controller...

Страница 14: ...mation if the network type is set to Genus compatible Press the Enter button to execute the command Up or Down buttons to cancel If the network type is not set to Genus compatible then the ClrA messag...

Страница 15: ...255 192 0 18 255 192 0 0 10 255 255 255 128 25 255 255 128 0 17 255 128 0 0 09 255 255 255 0 24 255 255 0 0 16 255 0 0 0 08 Mercury Switch Please refer to the Mercury Switch user guide which can be o...

Страница 16: ...ton presses The top bar of the left hand segment will be lit when the maximum temperature is being displayed The bottom bar of the left hand segment will be lit when the minimum temperature is being d...

Страница 17: ...Lights Only state if the current state is not Lights Only If the current state is Lights Only then the controller will change to the Normal state Selecting this option will exit the setup menu automat...

Страница 18: ...no requirement for forced cooling ventilation There is no requirement for forced cooling ventilation Class 2 Insulation No protective Earth is required and none should be fitted No protective Earth is...

Страница 19: ...Input type Selectable See Units Comms RS232 with flow control Switched Resistor Example Wiring Installation Panel Cut out and Clearances Mercury Mk2 Flush mount controller Dimensions Mercury Mk2 Fixin...

Страница 20: ...ch clip until it clicks to remove the controller Each clip has a mounting hole to provide an alternative fixing mechanism to DIN mounting Cleaning Do not wet the controller when cleaning Clean the fro...

Страница 21: ...ore installing or maintaining this product Mercury 2 Intuitive Mobile Controller User Guide www resourcedm com Revision History Revision Date Changes 1 0 23 01 2014 First Issue 1 1 29 01 2014 Maximum...

Отзывы: