room is the most likely place for a fire to start 

at night, followed by the kitchen (where a 

Heat Alarm is recommended) and then the 

dining room. Consideration should be given to 

installing Smoke Alarms in any bedrooms where 

fires might occur, for instance, where there is 

an electrical appliance such as an electric 

blanket or heater, or where the occupant is 

a smoker. In addition, consideration should 

be also given to installing Smoke Alarms in 

any rooms where the occupant is unable to 

respond very well to a fire starting in that 

room, such as an elderly or sick person or a 

very young child.

Checking Alarms Can Be Heard

With the Alarms sounding in their intended 

locations check that the alarm can be heard 

in each bedroom with the door closed, above 

the sound of any TV/audio systems. The TV/

audio systems should be set to a reasonably 

loud conversation level. If you cannot hear 

the alarm over the sound of the TV/audio 

system, the chances are it would not wake you. 

Interconnecting the Alarms will help to ensure 

that the alarm will be heard throughout the 

property.

Positioning

Ceiling Mounting

Hot smoke rises and spreads out, so a central 

ceiling position is the recommended location. 

The air is “dead” and does not move in corners, 

therefore Smoke Alarms must be mounted 

away from corners. Keep at least 305mm 

(12”) from walls and corners (see 

Figure 3

). 

Additionally, mount the unit at least 305mm 

(12”) from any light fitting or decorative 

object which might prevent smoke entering 

the Smoke Alarm.

Figure 3

PLACE IN CENTRAL

LOCATION AND 

NOT WITHIN

305mm (12”)

OF ANY CORNER

SMOKE ALARMS

<610mm (24”) FROM APEX

DEAD AIR 

SPACE

Wall Mounting

If ceiling mounting is impractical, Smoke Alarms 

may be mounted on a wall, provided that:

a) the top of the detection element is between 

150mm (6”) and 305mm (12”) below the ceiling 

(see; 

Figure 3a

).

b) the bottom of the detection element is 

above the level of any door openings;

Wall mounting should only be considered where 

close spaced beams or similar obstructions may 

Locate Heat Alarms in rooms adjoining escape 

routes - kitchens, garages, boiler houses etc. 

where Smoke Alarms are unsuitable.

Figure 1

For minimum protection

- Smoke Alarm on each storey
- in each sleeping area
- every 6.4 metres (21ft) of hallways and 

rooms

- within 3 metres (10ft) of all bedroom doors
- all units interconnected (where feature is 

present)

For recommended protection

(in addition to the above):

- Smoke Alarms in every room (except 

kitchens and bathrooms)

- Heat Alarms located in kitchens, garages 

etc. within 5.3m (17ft) of potential fire 
sources

Single Storey Dwelling

If the premises is one storey you should put 

your first Smoke Alarm in a corridor or hallway 

between the sleeping and living areas. Place it 

as near to the living area as possible, but make 

sure that it can be heard loudly enough in the 

bedroom to wake someone. See 

Figure 2

 for 

placement example.
In houses with more than one sleeping area, 

Smoke Alarms should be placed between each 

sleeping area and the living area and it is 

recommended that Heat Alarms should be 

placed in the kitchen and garage.

Figure 2

Bedroom

Bedroom

Bedroom

Bathroom

Bath

Dining Room

Laundry

Room

Living Room

Kitchen

Recommended Protection

Fire authorities recommend you put individual 

Smoke Alarms in or near all rooms where fire 

is most likely to break out (apart from the 

locations to avoid e.g bathrooms). The living 

4

Содержание RE314 DSC

Страница 1: ...mode and then holding down the smoke s test button until the smoke alarm beeps 5 Remove the mounting plate and refer to Sections 2 and 6 for positioning and installation 6 After mounting plate is inst...

Страница 2: ...ED Sounder Low Battery Off 1 Flash every 48 sec 1 Beep Faulty Smoke Sensor Off 2 Flashes every 48 sec 2 Beeps Faulty Heat Sensor Off 2 Flashes every 48 sec 2 Beeps End of Life Off 3 Flashes every 48 s...

Страница 3: ...tors The installation of smoke detectors in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in impro...

Страница 4: ...ALARMS 610mm 24 FROM APEX DEAD AIR SPACE Wall Mounting If ceiling mounting is impractical Smoke Alarms may be mounted on a wall provided that a the top of the detection element is between 150mm 6 and...

Страница 5: ...e quickly silenced by fanning vigorously with a newspaper or similar to remove the smoke or press the test hush button Do not attempt to recharge or burn the battery as it may explode If it is necessa...

Страница 6: ...nsurance The supplier or manufacturer is not your insurer Fire Safety Hints Store petrol and other flammable materials in proper containers Discard oily or flammable rags Always use a metal fireplace...

Страница 7: ...ng Maintenance and Power Supply Monitoring then contact Customer Assistance at the nearest address given at the end of this leaflet If it needs to be returned for repair or replacement put it in a pad...

Страница 8: ...l other Alarms in the system WARNING Do not test with flame This can set fire to the Alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special a...

Страница 9: ...ery 8 seconds to indicate that the unit has been silenced 2 The Smoke Alarm will reset to normal sensitivity at the end of the silenced period 10 minutes If additional silenced time is required simply...

Страница 10: ...sects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed In certain circumstances even with regular cleaning contamination can build up in the smoke sensing chamber causing the A...

Страница 11: ...larm fails to sound when the Test button is pressed Check the age of the unit see the replace by label on side of unit If necessary replace the battery or batteries with Panasonic CR123A 9 System Comp...

Страница 12: ...ice may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux cnr d Industr...

Отзывы: