background image

© RESOL 07089 

VA32.monen.ind

d

| 4

RESOL  VA32

K

VS 

values for F3L Rotodiv.

1. Installation advice
The installation of the valve must be carried out correspon-
ding to the approved technical regulations. Rests of sealing 
material and rests of hemp must not get into the valve body. 
In order to avoid blocking of the valve ball, the following 
advice has to be considered and all solder, brazing or welding 
processes near the valve are to be avoided.

Important advice
In order to attain the maximum operating safety and relia-
bility, it is recommended to flush the system and to insert 
an appropriate strainer (0,65 µm) in front of each valve (see 
installation scheme). 

3. Change of flow direction
 
Change of flow direction A<>AB to AB<>B when the relay 
is in rest position.
•  Unscrew green housing cover. 
• Unscrew sink screw and remove the actuator. Set the ro-

tary slide to the desired basic position (displace the lens 
head screws by 90 °). 

• Attach the actuator (until it locks) and tighten screw after 

the mounting has been finished. Fasten the cover with the 
screws. Functional control. 

Mounting and demounting 
of valve and actuator

Change of flow direction

4. Dimensions

2. Installation position

The valve can be mounted in any position, but not with the 
actuator to the bottom. In order to use the hand operation 
+/- 90 °, a cable loop of approx. 25 cm has to be arranged 
during the electrical connection. In order to have enough 
space to carry out maintenance work, a distance of at least 
100 mm from the wall or the device respectively has to be 
kept.

A

B

AB

A

B

AB

Содержание VA32

Страница 1: ...VA32 RESOLVA32 Mounting Connection Manual control Maintenance Examples Thank you for buying this RESOL product Please read this manual carefully to get the best performance from this unit www resol de ...

Страница 2: ...Work Act 1974 Part P of the Building Regulations 2005 BS7671 Requirements for electrical installations and relevant safety re gulations of DIN EN DVGW TRGI TRF andVDE These instructions are exclusively addressed to authorised skilled per sonnel Only qualified electricians should carry out electrical works Initial installation should be effected by qualified personnel named by the manufacturer Decla...

Страница 3: ...gnal output of the limit switch in valve position can be used for control purposes max 1 A The actuator can be quickly replaced without having to dismount the unit No flow reduction full passage corresponding to the versions DN20 DN32 Technical data Actuator Operating voltage 230V Power consumption standby 3VA otherwise 7 5VA Protection type II EN60335 1 Actuator safety class IP 44 IEC529 Limit swi...

Страница 4: ... of flow direction Change of flow direction A AB to AB B when the relay is in rest position Unscrew green housing cover Unscrew sink screw and remove the actuator Set the ro tary slide to the desired basic position displace the lens head screws by 90 Attach the actuator until it locks and tighten screw after the mounting has been finished Fasten the cover with the screws Functional control Mounting a...

Страница 5: ...l line N 240V Red limit switch output signal 5 On off control with permanent phase L Attention Fuse the operating voltage with external pre fuse max 2 A Red limit switch lead is bared and carries voltage when the valve is in the open position 7 Examples Solar system with 2 collectors and two storages with 3 port valve in order to change storage loading in layers Solar system with 1 collector and 1...

Страница 6: ... RESOL 07089 VA32 monen indd 6 RESOL VA32 Notes ...

Страница 7: ... RESOL 07089 VA32 monen indd RESOL VA32 7 Notes ...

Страница 8: ...ally applies for copies translations micro films and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a lot of care with the texts and drawings of this manual and to the best of our knowledge and consent As faults can never be excluded please note Your own calcu lations and plans under consideration of the current stan dards and DIN directions ...

Отзывы: