en
Installation
Configuration
Data expor
t / configuration
W
eb interface
Eliminating er
rors
30
Indications
Problem
Solution
The KM1
Communication module
is not found by the
DeviceDiscoveryTool.
In order to check the automatic IP address retrieval,
proceed as follows:
Î
Click the Start symbol on the task bar.
Î
In the Settings menu, select the Control panel.
Î
Double-click Network connections.
Î
Right-click the KM1 Communication module con-
nection.
Î
Click Properties.
Î
Mark TCP/IP Internet protocol.
Î
Click the Properties button.
Î
Mark the Obtain IP address automatically
field.
Î
Mark the Obtain DNS server address auto-
matically field.
Î
Close all windows by clicking OK.
Î
Check if the proxy server settings for the opera-
ting system are correct.
The KM1
Communication module
is not found by the
DeviceDiscoveryTool.
In order to check if the proxy server settings for the
operating system are correct, proceed as follows:
Î
Click the Start symbol on the task bar.
Î
In the Settings menu, select the Control panel.
Î
Double-click the Internet Options symbol.
Î
Click the Connections tab.
Î
Click the Settings button.
Î
Tick the Use a proxy server for your LAN
checkbox.
Î
Click the Advanced… button.
Î
Enter 169.254.0.0/16 into the Exceptions input
field.
Î
Close all windows by clicking OK.
Î
Check if the proxy server settings for the Internet
browser are correct.
Problem
Solution
The KM1
Communication module
is not found by the
DeviceDiscoveryTool.
In order to check if the proxy server settings for the
internet browser are correct, proceed as follows:
Î
Open the Internet browser.
Î
In the main menu Extras, select the sub-menu
Settings.
Î
In the main menu Advanced, select the sub-menu
Network.
Î
Click the Settings button.
Î
Enter 169.254.0.0/16in the No proxy for: field.
Î
Close all windows by clicking OK.