HKM2
9
|
3. Operation and adjustment
Connect the HKM2 module to the main controller via
the RESOL VBus
®
. Activate the HK-Module with the
corresponding menu option. From the
DeltaSol
®
M
version 1.10 on you can choose between “No”, “HKM1”
and “HKM2”, in the previous versions between “Yes” and
“No”. All parameters are shown on the corresponding
menu (HK-Module).
If more than one HKM2 module are to be connected to
one controller, a subadress has to be allocated to each
HKM2 module via the menu of the controller.
•
select the menu channel SA by pressing buttons 1
and 2
•
press the “set”-button, “SA” indication flashes
•
allocate a number to each HKM2 module (e. g. “2” for the
second, “3” for the third HKM2 module connected)
3.1 Control parameter and display channels
• EC Error Code
Error Code, display channel HKM2
0 = OK
1 = sensor fault
2 = bus defect
• VC Version Compatibility
System recognition of the HKM2 by the controller
display channel HKM2
0 = bus defect
1 = HKM1
3 = HKM2
• SA SubAddress
Subadress for operation of VBus
®
Adjustment channel HKM2
• MM Manual Mode
State of the relays, only if manual control switch
is set to I
0 = R1 on, R3 on
1 = R1 on, R2 on
2 = R1 on
• PG ProGramme
Hardware version
Display channel HKM2
• VN VersioN
Software version,
Display channel HKM2
• FL FLow
Current flow temperature,
Display channel controller
• FS Flow Set
Current flow set temperature,
Display channel controller
• OU OUtdoor
Current outdoor temperature,
Display channel controller
• S1 Store temperature 1
Current temperature of store sensor 1,
Display channel controller
• S2 Store temperature 2
Current temperature of store sensor 2,
Display channel controller
• RA Remote Adjustement
Adjustment of the remote control
Display channel controller
• S6 Sensor 6
Measured value only, without function
Display channel controller
• R1 Relay 1: Heating circuit pump
Current state of the relay heating circuit pump
Display channel controller
• R2 Relay 2: Mixer on
Current state of the relay for opening up
the mixer, display channel controller
• R3 Relay 3: Mixer off
Current state of the relay for shutting down
the mixer, display channel controller
• R5 Relay 5: After-heating
Current state of the relay after-heating,
display channel controller
HKM2 channels