For control- and service work the operating mode of
the controller can be manually adjusted by selecting the
adjustment value HND1 / HND2, in which the following
adjustments can be made:
4.1.18 Operating mode
• HND1 / HND2
Operating mode
OFF
:
relay off
(flashing) +
AUTO :
relay in automatic operation
ON
:
relay on
(flashing) +
HND1/HND2:
Operating mode
Adjustment range:
OFF, AUTO, ON
Factory setting: AUTO
The thermostat function works independently from the
solar operation and can e.g. be used for use of surplus
energy or an after-heating.
• AH O < AH F
the thermostat function is used for after-heating
• NH O > AH F
the thermostat function is used for use of surplus
energy
On the display is shown
if the second relay output is
activated.
4.1.17 Thermostat function
(Arr = 3)
after-heating
use of surpluse energy
4.1.19 Language
The menu language can be adjusted in this channel.
• dE : German
• En : English
• It : Italiano
• Fr : French
LANG:
Adjustment of language
Adjustment range:
dE, En, It, Fr
Factory setting: En
4.1.20 Unit
The menu unit can be adjusted:
• °FAH
• °CEL
UNIT:
Adjustment of unit
Adjustment range: FAH, °C
Factory setting: FAH
AH O:
Thermostat-
switch-on tem perature
Adjustment range 30 ... 205°F
Factory setting 105°F
AH F:
Thermostat-
switch-off tem pe rature
Adjustment range 30 ... 205°F
Factory setting 115°F