DeltaSol
®
BS Pro
© RESOL 06250 deltasol_bs_pr
o.monen.ind
d
11
|
The system screen (active system scheme) shows the
schemes selected on the controller. It consists of several
system component symbols, which are - depending on the
current status of the system - either flashing, permanently
shown or hidden.
Sensors
Collector 1
Collector 2
Pumps
Heating circuit
Sensor
Additional symbol for
operation of the burner
Valves
Store
Store heat exchanger
Store 2 or after-heating (with
additional symbol)
Sensor store up
Valve
Collectors
with collector sensor
Pump
3-way-valves
The flow direction or the current bre-
aking capacity are always shown.
Heating circuit
Store 1 and 2
with heat exchanger
After-heating
with burner symbol
Temperature sensor
2.2.3 System screen
only system screen
Constantly green:
everything all right
Red/green blinking: initialisation phase
manual operation
Red blinking:
sensor defect
(sensor symbol is quickly blinking)
2.3 Blinking codes
2.3.2 LED blinking codes
2.3.1 System screen blinking codes
• Pumps are blinking during starting phase
• Sensors are blinking if the respective sensor-indication
channel is selected.
• Sensors are quickly blinking in case of sensor defect.
• Burner symbol is blinking if after-heating is activated.