SV9440, SV9540, AND SV9640 SMARTVALVE™ SYSTEM CONTROLS
69-1227—02
6
5.
Connect the other end of the tubing to the pilot
burner according to the instructions supplied with
the Q3450/Q3480.
NOTE:
The pilot tubing provides the SmartValve Sys-
tem flame sense current path. Make sure the
connections are clean and tight for proper oper-
ation.
Wiring
Follow the wiring instructions furnished by the appliance
manufacturer, if available, or use the general instructions
provided below. When these instructions differ from the
appliance manufacturer, follow the appliance
manufacturer instructions.
All wiring must comply with applicable electrical codes
and ordinances.
Fig. 5. Proper use of wrench on ignition system control with and without flanges.
Fig. 6. Top view of ignition system control.
APPLY WRENCH FROM TOP OR
BOTTOM OF IGNITION SYSTEM
CONTROL TO EITHER SHADED AREA
WHEN FLANGE IS NOT USED
APPLY WRENCH
TO FLANGE ONLY
WHEN FLANGE IS USED
M12169A
M10965A
HI-LO
ADJUSTMENT SCREWS
(UNDER CAP)
REGULATOR
VENT COVER
INLET
HI
LO
OFF
ON
PRESSURE REGULATOR
ADJUSTMENT (UNDER
CAP SCREW)
INLET
PRESSURE
TAP
INLET
IGNITION SYSTEM
CONTROL SWITCH
CONTROLS
CONNECTOR
PILOT
OUTLET
OUTLET
OUTLET
PRESSURE
TAP
IGNITER
CONNECTOR
LINE VOLTAGE
CONNECTOR
C1
C2
C3