RESI®
Titel:
Manual RESI-DALI-ASCII
Datum
Seite
Von
14.02.2015
21
89
.
P
ro
p
ri
e
ta
ry
d
a
ta
,
co
m
p
a
n
y
co
n
fid
e
n
ti
a
l.
A
ll
r
ig
h
ts
re
s
e
rv
e
d
.
C
o
n
fié
à
tit
re
d
e
se
c
re
t
d
'e
n
tr
e
p
ri
s
e
.
T
o
u
s
d
ro
its
r
é
se
rv
é
s
.
C
o
m
u
n
ic
a
d
o
c
o
m
o
se
g
re
d
o
e
m
p
re
sa
ri
a
l.
R
e
se
rv
a
d
o
s
to
d
o
s
o
s
d
ir
e
ito
s.
C
o
n
fid
a
d
o
co
m
o
s
e
cr
e
to
i
n
d
u
s
tr
ia
l.
N
o
s
re
s
e
rv
a
m
o
s
t
o
d
o
s
l
o
s
d
e
re
c
h
o
s
.
.
.
W
e
it
e
rg
a
b
e
s
o
w
ie
V
e
r
v
ie
lf
ä
lt
ig
u
n
g
d
ie
s
e
r
U
n
te
rl
a
g
e
,
V
e
r-
w
e
rt
u
n
g
u
n
d
M
it
te
ilu
n
g
ih
re
s
In
h
a
lt
s
n
ic
h
t
g
e
s
ta
tt
e
t,
s
o
w
e
it
n
ic
h
t
a
u
s
d
r
ü
c
k
lic
h
z
u
g
e
s
ta
n
d
e
n
.
Z
u
w
id
e
rh
a
n
d
lu
n
g
e
n
v
e
r-
p
fl
ic
h
te
n
z
u
S
c
h
a
d
e
n
e
rs
a
tz
.
A
ll
e
R
e
c
h
te
v
o
rb
e
h
a
lt
e
n
,
in
s
b
e
-
s
o
n
d
e
re
fü
r
d
e
n
F
a
ll
d
e
r
P
a
te
n
te
rt
e
il
u
n
g
o
d
e
r
G
M
-E
in
tr
a
g
u
n
g
.
.
7.10
Switch off a single lamp
This command sends the DALI command OFF to a single DALI lamp. The DALI standard supports 64 DALI lamps
(short addresses).
Host long version:
#LAMP<SP>OFF:<LAMP><CR> or
#<ADR>,LAMP<SP>OFF:<LAMP><CR>
Host short version:
#LOF:<LAMP><CR> or #<ADR>,LOF:<LAMP><CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or #<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR>
<LAMP> represents the affected short address of the lamp according to the DALI standard. The short address
range 0 to 63 is allowed.
Samples:
Switch off lamp 27:
#LAMP
OFF:27
CR
#OK
CR
#255,LOF:0x1B
CR
#255,OK
CR
Switch off lamp 63:
#LAMP
OFF:63
CR
#OK
CR
#255,LOF:0x3F
CR
#255,OK
CR
7.11
Dim up all lamps
This command dims up all lamps a little bit with the DALI command UP. It is very important, that the lamps have
to be on, before you send this command. Otherwise this command is ignored by the lamp. Each lamp can be
dimmed up to their maximum brightness value.
Host long version:
#ALL<SP>UP<CR> or #<ADR>,ALL<SP>UP<CR>
Host short version:
#AUP<CR> or #<ADR>,AUP<CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or #<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR>
Samples:
Dim up all lamps: