RESI®
Titel:
Manual RESI-DALI-ASCII
Datum
Seite
Von
14.02.2015
34
89
.
P
ro
p
ri
e
ta
ry
d
a
ta
,
co
m
p
a
n
y
co
n
fid
e
n
ti
a
l.
A
ll
r
ig
h
ts
re
s
e
rv
e
d
.
C
o
n
fié
à
tit
re
d
e
se
c
re
t
d
'e
n
tr
e
p
ri
s
e
.
T
o
u
s
d
ro
its
r
é
se
rv
é
s
.
C
o
m
u
n
ic
a
d
o
c
o
m
o
se
g
re
d
o
e
m
p
re
sa
ri
a
l.
R
e
se
rv
a
d
o
s
to
d
o
s
o
s
d
ir
e
ito
s.
C
o
n
fid
a
d
o
co
m
o
s
e
cr
e
to
i
n
d
u
s
tr
ia
l.
N
o
s
re
s
e
rv
a
m
o
s
t
o
d
o
s
l
o
s
d
e
re
c
h
o
s
.
.
.
W
e
it
e
rg
a
b
e
s
o
w
ie
V
e
r
v
ie
lf
ä
lt
ig
u
n
g
d
ie
s
e
r
U
n
te
rl
a
g
e
,
V
e
r-
w
e
rt
u
n
g
u
n
d
M
it
te
ilu
n
g
ih
re
s
In
h
a
lt
s
n
ic
h
t
g
e
s
ta
tt
e
t,
s
o
w
e
it
n
ic
h
t
a
u
s
d
r
ü
c
k
lic
h
z
u
g
e
s
ta
n
d
e
n
.
Z
u
w
id
e
rh
a
n
d
lu
n
g
e
n
v
e
r-
p
fl
ic
h
te
n
z
u
S
c
h
a
d
e
n
e
rs
a
tz
.
A
ll
e
R
e
c
h
te
v
o
rb
e
h
a
lt
e
n
,
in
s
b
e
-
s
o
n
d
e
re
fü
r
d
e
n
F
a
ll
d
e
r
P
a
te
n
te
rt
e
il
u
n
g
o
d
e
r
G
M
-E
in
tr
a
g
u
n
g
.
.
#255,LRMAXL:0x2F
CR
#255,OK
CR
Recall maximum level in lamp 58:
#LAMP
RECALL
MAX
LEVEL:58
CR
#OK
CR
#255,LRMAXL:0x3A
CR
#255,OK
CR
7.32
Recall maximum level in all lamps
This command sends the DALI command RECALL MIMIMUM LEVEL to all DALI lamps. All lamps dim down to
their individual stored minimum brightness values. If the lamps are off, they are switched on by this command.
Host long version:
#ALL<SP>RECALL<SP>MIN<SP>LEVEL<CR> or
#<ADR>,ALL<SP>RECALL<SP>MIN<SP>LEVEL<CR>
Host short version:
#ARMINL<CR> or #<ADR>,ARMINL<CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or #<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR>
Samples:
Recall minimum level in all lamps:
#ALL
RECALL
MIN
LEVEL
CR
#OK
CR
#255,ARMINL
CR
#255,OK
CR
7.33
Recall minimum level in a lamp group
This command sends the DALI command RECALL MINIIMUM LEVEL to a DALI lamp group. All lamps of the
affected group dim down to their individual stored minimum brightness values. If the lamps are off, they are
switched on by this command. The DALI standard supports 16 lamp groups.
Host long version:
#GROUP<SP>RECALL<SP>MIN<SP>LEVEL:<GROUP><CR> or
#<ADR>,GROUP<SP>RECALL<SP>MIN<SP>LEVEL:<GROUP><CR>
Host short version:
#GRMINL:<GROUP><CR> or #<ADR>,GRMINL:<GROUP><CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or #<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with