RESI®
Titel:
Manual RESI-DALI-ASCII
Datum
Seite
Von
14.02.2015
52
89
.
P
ro
p
ri
e
ta
ry
d
a
ta
,
co
m
p
a
n
y
co
n
fid
e
n
ti
a
l.
A
ll
r
ig
h
ts
re
s
e
rv
e
d
.
C
o
n
fié
à
tit
re
d
e
se
c
re
t
d
'e
n
tr
e
p
ri
s
e
.
T
o
u
s
d
ro
its
r
é
se
rv
é
s
.
C
o
m
u
n
ic
a
d
o
c
o
m
o
se
g
re
d
o
e
m
p
re
sa
ri
a
l.
R
e
se
rv
a
d
o
s
to
d
o
s
o
s
d
ir
e
ito
s.
C
o
n
fid
a
d
o
co
m
o
s
e
cr
e
to
i
n
d
u
s
tr
ia
l.
N
o
s
re
s
e
rv
a
m
o
s
t
o
d
o
s
l
o
s
d
e
re
c
h
o
s
.
.
.
W
e
it
e
rg
a
b
e
s
o
w
ie
V
e
r
v
ie
lf
ä
lt
ig
u
n
g
d
ie
s
e
r
U
n
te
rl
a
g
e
,
V
e
r-
w
e
rt
u
n
g
u
n
d
M
it
te
ilu
n
g
ih
re
s
In
h
a
lt
s
n
ic
h
t
g
e
s
ta
tt
e
t,
s
o
w
e
it
n
ic
h
t
a
u
s
d
r
ü
c
k
lic
h
z
u
g
e
s
ta
n
d
e
n
.
Z
u
w
id
e
rh
a
n
d
lu
n
g
e
n
v
e
r-
p
fl
ic
h
te
n
z
u
S
c
h
a
d
e
n
e
rs
a
tz
.
A
ll
e
R
e
c
h
te
v
o
rb
e
h
a
lt
e
n
,
in
s
b
e
-
s
o
n
d
e
re
fü
r
d
e
n
F
a
ll
d
e
r
P
a
te
n
te
rt
e
il
u
n
g
o
d
e
r
G
M
-E
in
tr
a
g
u
n
g
.
.
Samples:
Do STORE DTR AS MIN LEVEL command in lamp group 4:
#GROUP
STORE
DTR
AS
MIN
LEVEL:4
CR
#OK
CR
#255,GSDMINL:0x04
CR
#255,OK
CR
7.64
Do STORE DTR AS MIN LEVEL command in a single lamp
This command send the DALI command STORE DTR AS MIN LEVEL to a single lamp twice within 100ms. The
DALI standard supports 64 lamps.
Host long version:
#LAMP<SP>STORE<SP>DTR<SP>AS<SP>MIN<SP>LEVEL:<LAMP><CR> or
#<ADR>,LAMP<SP>STORE<SP>DTR<SP>AS<SP>MIN<SP>LEVEL:<LAMP><CR>
Host short version:
#LSDMINL:<LAMP><CR> or
#<ADR>,LSDMINL:<LAMP><CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or #<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR>
<LAMP> represents the affected short address of the lamp according to the DALI standard. The short address
range 0 to 63 is allowed.
Samples:
Do STORE DTR AS MIN LEVEL command in lmap 46:
#LAMP
STORE
DTR
AS
MIN
LEVEL:47
CR
#OK
CR
#255,LSDMINL:0x2F
CR
#255,OK
CR
7.65
Do STORE DTR AS SYSTEM FAILURE LEVEL command in all lamps
This command send the DALI command STORE DTR AS SYSTEM FAILURE LEVEL to all lamps twice within
100ms.
Host long version:
#ALL<SP>STORE<SP>DTR<SP>AS<SP>SYSTEM<SP>FAILURE<SP>LEVEL<CR> or
#<ADR>,ALL<SP>STORE<SP>DTR<SP>AS<SP>SYSTEM<SP>FAILURE<SP>LEVEL<CR>
Host short version:
#ASDSFL<CR> or
#<ADR>,ASDSFL<CR>
Answer:
If everything was ok with the command, the converter answers with
#OK<CR> or
#<ADR>,OK<CR>
If the DALI bus has no power, the converter answers with
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR>
If there is a syntax problem with the command, the converter answers with