background image

RESI® 

  

Titel: 

Manual RESI-DALI-ASCII

 

Datum 

Seite 

Von 

14.02.2015 

52 

89 

 

.

P

ro

p

ri

e

ta

ry

 

 

 d

a

ta

 

 

co

m

p

a

n

  

co

n

fid

e

n

ti

a

l. 

 

 

 A

ll 

 r

ig

h

ts

 

  

re

s

e

rv

e

d

.

C

o

n

fié

 

  

à

 

  

tit

re

 

 

d

e

  

se

c

re

  

d

'e

n

tr

e

p

ri

s

e

 T

o

u

 d

ro

its

 

 

 r

é

se

rv

é

s

.

C

o

m

u

n

ic

a

d

o

 c

o

m

o

 

se

g

re

d

o

 e

m

p

re

sa

ri

a

l. 

R

e

se

rv

a

d

o

to

d

o

o

 

d

ir

e

ito

s.

C

o

n

fid

a

d

o

 

co

m

o

 s

e

cr

e

to

 i

n

d

u

s

tr

ia

l. 

N

o

re

s

e

rv

a

m

o

s

 t

o

d

o

s

 l

o

s

 d

e

re

c

h

o

s

.

 

 

.

W

e

it

e

rg

a

b

e

 

 

s

o

w

ie

 

 

V

e

r

v

ie

lf

ä

lt

ig

u

n

g

 

 

d

ie

s

e

U

n

te

rl

a

g

e

 

 

V

e

r-

w

e

rt

u

n

g

 

 

u

n

d

 

 

M

it

te

ilu

n

g

 

 

ih

re

s

 

In

h

a

lt

s

 

n

ic

h

g

e

s

ta

tt

e

t,

 

s

o

w

e

it

n

ic

h

 

a

u

s

d

r

ü

c

k

lic

h

 

 

z

u

g

e

s

ta

n

d

e

n

 

 

Z

u

w

id

e

rh

a

n

d

lu

n

g

e

n

 

 

v

e

r-

p

fl

ic

h

te

n

 

z

u

 

S

c

h

a

d

e

n

e

rs

a

tz

 

 

A

ll

e

 

R

e

c

h

te

 

v

o

rb

e

h

a

lt

e

n

in

s

b

e

-

s

o

n

d

e

re

 

d

e

n

 

F

a

ll 

d

e

P

a

te

n

te

rt

e

il

u

n

g

 

o

d

e

G

M

-E

in

tr

a

g

u

n

g

.

.

Samples: 
Do STORE DTR AS MIN LEVEL command in lamp group 4: 

 #GROUP

STORE

DTR

AS

MIN

LEVEL:4

CR

 

 #OK

CR 

 

 #255,GSDMINL:0x04

CR

 

 #255,OK

CR 

7.64 

Do STORE DTR AS MIN LEVEL command in a single lamp 

This command send the DALI command STORE DTR AS MIN LEVEL to a single lamp twice within 100ms. The 
DALI standard supports 64 lamps. 
 
Host long version: 
#LAMP<SP>STORE<SP>DTR<SP>AS<SP>MIN<SP>LEVEL:<LAMP><CR> or 
#<ADR>,LAMP<SP>STORE<SP>DTR<SP>AS<SP>MIN<SP>LEVEL:<LAMP><CR> 
 
Host short version: 
#LSDMINL:<LAMP><CR> or 
#<ADR>,LSDMINL:<LAMP><CR> 
 
Answer: 
If everything was ok with the command, the converter answers with  
#OK<CR> or #<ADR>,OK<CR> 
 
If the DALI bus has no power, the converter answers with 
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR> 
 
If there is a syntax problem with the command, the converter answers with  
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR> 
 
<LAMP> represents the affected short address of the lamp according to the DALI standard. The short address 
range 0 to 63 is allowed.  
 
Samples: 
Do STORE DTR AS MIN LEVEL command in lmap 46: 

 #LAMP

STORE

DTR

AS

MIN

LEVEL:47

CR

 

 #OK

CR 

 

 #255,LSDMINL:0x2F

CR

 

 #255,OK

CR 

7.65 

Do STORE DTR AS SYSTEM FAILURE LEVEL command in all lamps 

This command send the DALI command STORE DTR AS SYSTEM FAILURE LEVEL to all lamps twice within 
100ms. 
  
Host long version: 
#ALL<SP>STORE<SP>DTR<SP>AS<SP>SYSTEM<SP>FAILURE<SP>LEVEL<CR> or 
#<ADR>,ALL<SP>STORE<SP>DTR<SP>AS<SP>SYSTEM<SP>FAILURE<SP>LEVEL<CR> 
 
Host short version: 
#ASDSFL<CR> or 
#<ADR>,ASDSFL<CR> 
 
Answer: 
If everything was ok with the command, the converter answers with  
#OK<CR> or 
#<ADR>,OK<CR> 
 
If the DALI bus has no power, the converter answers with 
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR> 
 
If there is a syntax problem with the command, the converter answers with  

Содержание RESI-DALI-ASCII

Страница 1: ...ASCII RESI DALI PS Great care has been taken in the creation of the text illustrations and program examples in this manual RESI Informatik Automation GmbH company the editors and publishers accept no...

Страница 2: ...os direitos Confidado como secreto industrial Nos reservamos todos los derechos Weitergabe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nich...

Страница 3: ...7 15 DIM DOWN A LAMP GROUP 24 7 16 DIM DOWN A SINGLE LAMP 24 7 17 SWITCH ON AND DIM UP ALL LAMPS 25 7 18 SWITCH ON AND DIM UP A GROUP OF LAMPS 25 7 19 SWITCH ON AND DIM UP A SINGLE LAMP 26 7 20 DIM D...

Страница 4: ...COMMAND IN A GROUP OF LAMPS 54 7 70 DO STORE DTR AS POWER ON LEVEL COMMAND IN A SINGLE LAMP 55 7 71 DO STORE DTR AS FADE TIME COMMAND IN ALL LAMPS 55 7 72 DO STORE DTR AS FADE TIME COMMAND IN A GROUP...

Страница 5: ...Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragun...

Страница 6: ...e technical specifications and tolerances given in the technical manuals for the product If you do not obey this issue the proper performance of the device cannot be guaranteed This can lead to fail f...

Страница 7: ...n Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung Our devices must not be used for monitoring applications wh...

Страница 8: ...need an intelligent unit with a build in serial interface RS232 or RS485 The unit must be able to send and receive ASCII text messages This is available in almost every media control system like CREST...

Страница 9: ...x 90mm x 58mm Weight RESI DALI MODBUS 55g RESI DALI PS 65g Mounting on DIN EN50022 rail only RESI DALI ASCII ASCII Modbus Interface Factory settings Protocol ASCII or Modbus RTU ASCII Modbus address...

Страница 10: ...lich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 5 Mounting and Connections 5 1 Assembling Ou...

Страница 11: ...m the DIN rail first open the clamp lever with a screwdriver on the bottom side 4 Hold the clamp lever opened while you lift the module from the DIN rail 5 Then remove the converter from the bar with...

Страница 12: ...cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung RESI DALI PS L M Power supply L 24 V M Gro...

Страница 13: ...ation Description of the DIP switch settings and LED status displays DIP Switch Description Baudrate BR Use DIP Switches 1 2 to select baud rate OFF OFF 9600Bd ON OFF 19200Bd OFF ON 38400Bd ON ON 5760...

Страница 14: ...rvamos todos los derechos Weitergabe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflic...

Страница 15: ...propriate standards see EN60929 For the communication via ASCII text strings all ASCII messages start with a special character 0x23 35dec and end with the special character CARRIAGE RETURN 0x0d 13dec...

Страница 16: ...allowed as hexadecimal numbers All converters on the bus react to the broadcast bus number 0 and to its own configured bus number With an external DIP switch you can switch very fast between the fixe...

Страница 17: ...or ADR VER CR Answer VERSION HIGH MED LOW CR or ADR VERSION HIGH MED LOW CR HIGH MED LOW describe the current software version e g 3 0 0 Samples VERSIONCR VERSION 3 0 0CR With broadcast address in dec...

Страница 18: ...answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR LEVEL represents the new brightness value according to the DALI standard You can use brightness levels between 0 0 and 254 100 255 is...

Страница 19: ...n LAMP SP LEVEL LAMP LEVEL CR or ADR LAMP SP LEVEL LAMP LEVEL CR Host short version LL LAMP LEVEL CR or ADR LL LAMP LEVEL CR Answer If everything was ok with the command the converter answers with OK...

Страница 20: ...is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Switch off all lamps ALL OFFCR OKCR 255 AOFCR 255 OKCR 7 9 Switch off all l...

Страница 21: ...ter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERR...

Страница 22: ...UP GROUP CR or ADR GROUP SP UP GROUP CR Host short version GUP GROUP CR or ADR GUP GROUP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus...

Страница 23: ...the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed Samples Dim up lamp 47 LAMP UP 47CR OKCR 255 LUP 0x2FCR 255 OKCR Dim up lamp 58 LAMP UP...

Страница 24: ...was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there i...

Страница 25: ...STEP UP If the lamps are off this commands switches on the lamps first Each lamp can be dimmed up to their maximum brightness value Host long version ALL SP ON SP AND SP STEP SP UP CR or ADR ALL ON SP...

Страница 26: ...p 4 GROUP ON AND STEP UP 4CR OKCR 255 GOSUP 0x04CR 255 OKCR Switch on and dim up group 32 GROUP ON AND STEP UP 32CR OKCR 255 GOSUP 0x20CR 255 OKCR 7 19 Switch on and dim up a single lamp This command...

Страница 27: ...DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP E...

Страница 28: ...a little bit with the DALI command STEP DOWN AND OFF If the lamp dim below its current minimum brightness this commands switches off the lamp The DALI standard supports 64 lamps Host long version LAM...

Страница 29: ...ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Di...

Страница 30: ...r If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERRO...

Страница 31: ...version GROUP SP STEP SP DOWN GROUP CR or ADR GROUP SP STEP SP DOWN GROUP CR Host short version GSDO GROUP CR or ADR GSDO GROUP CR Answer If everything was ok with the command the converter answers w...

Страница 32: ...R 255 OKCR Dim down immediately lamp 58 LAMP STEP DOWN 58CR OKCR 255 LSDO 0x3ACR 255 OKCR 7 29 Recall maximum level in all lamps This command sends the DALI command RECALL MAXIMUM LEVEL to all DALI la...

Страница 33: ...ected DALI group according to the DALI standard Group numbers from 0 to 15 are allowed Samples Recall maximum level in group 4 GROUP RECALL MAX LEVEL 4CR OKCR 255 GRMAXL 0x04CR 255 OKCR Recall maximum...

Страница 34: ...ARMINL CR or ADR ARMINL CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR...

Страница 35: ...OKCR 7 34 Recall minimum level in a single lamp This command sends the DALI command RECALL MINIMUM LEVEL to a single DALI lamp The affected lamp dim down to its individual stored minimum brightness va...

Страница 36: ...converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX...

Страница 37: ...e answer of the lamp is returned as a number The DALI standard supports 64 lamps Host long version LAMP SP COMMAND SP ANSWER LAMP COMMAND CR or ADR LAMP SP COMMAND SP ANSWER LAMP COMMAND CR Host short...

Страница 38: ...the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYN...

Страница 39: ...single lamp This command sends a DALI command to a single lamp twice within 100ms The answer of the lamp is returned as a number The DALI standard supports 64 lamps Host long version LAMP SP COMMAND...

Страница 40: ...P ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR COMMAND defines a valid 8 bi...

Страница 41: ...no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or A...

Страница 42: ...erter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP E...

Страница 43: ...e command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax prob...

Страница 44: ...tness value Arc power for a single lamp The DALI standard supports 64 lamps Host long version LAMP SP ARC SP POWER LAMP ARCPOWER CR or ADR LAMP SP ARC SP POWER LAMP ARCPOWER CR Host short version LARC...

Страница 45: ...GOTO SCENE 15CR OKCR 255 AGS 0x0FCR 255 OKCR 7 51 Recall scene in a group of lamps This command recalls a previous stored scene in a group of lamps The DALI standard supports 16 lamp groups and 16 DA...

Страница 46: ...rs with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR LAMP represents the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed SCENE defi...

Страница 47: ...ith the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR GROUP defines the affected DALI group according to the DALI standard Group numbers from 0 to 15 are allo...

Страница 48: ...R or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Do STORE ACTUAL LEVEL IN DTR...

Страница 49: ...R or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answer...

Страница 50: ...answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR...

Страница 51: ...rter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the comman...

Страница 52: ...SDMINL LAMP CR or ADR LSDMINL LAMP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS...

Страница 53: ...DTR SP AS SP SYSTEM SP FAILURE SP LEVEL GROUP CR Host short version GSDSFL GROUP CR or ADR GSDSFL GROUP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If...

Страница 54: ...OWER ON LEVEL to all lamps twice within 100ms Host long version ALL SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL CR or ADR ALL SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL CR Host short version ASDP...

Страница 55: ...DTR AS POWER ON LEVEL to a single lamp twice within 100ms The DALI standard supports 64 lamps Host long version LAMP SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL LAMP CR or ADR LAMP SP STORE SP DTR...

Страница 56: ...the DALI command STORE DTR AS FADE TIME to a group of lamps twice within 100ms The DALI standard supports 16 lamp groups Host long version GROUP SP STORE SP DTR SP AS SP FADE SP TIME GROUP CR or ADR...

Страница 57: ...to 63 is allowed Samples Do STORE DTR AS FADE TIME in lamp 47 LAMP STORE DTR AS FADE TIME 47CR OKCR 255 LSDFT 0x2FCR 255 OKCR 7 74 Do STORE DTR AS FADE RATE command in all lamps This command send the...

Страница 58: ...RATE in lamp group 4 GROUP STORE DTR AS FADE RATE 4CR OKCR 255 GSDFR 0x04CR 255 OKCR 7 76 Do STORE DTR AS FADE RATE command in a single lamp This command send the DALI command STORE DTR AS FADE RATE...

Страница 59: ...stored as brightness value Valid is 0 to 15 for the 16 possible scenes Samples Do STORE DTR AS SCENE 12 in all lamps ALL STORE DTR AS SCENE 12CR OKCR 255 ASDS 0xCCR 255 OKCR 7 78 Do STORE DTR AS SCENE...

Страница 60: ...er the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR...

Страница 61: ...f the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTA...

Страница 62: ...X CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power t...

Страница 63: ...CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the conv...

Страница 64: ...s sends no answer and the result will be a timeout 9 99 0x63 255 LQLF 0x2FCR 255 OK 1 255 0xFFCR 7 86 Do QUERY LAMP POWER ON in a single lamp This command checks with the DALI command QUERY LAMP POWER...

Страница 65: ...or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the c...

Страница 66: ...LTHEX is the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY RESET STATE in lamp 47 LAMP QUERY RESET STATE 47CR OK 1 255 0xFFCR The return value of 255 0xFF means YES the lam...

Страница 67: ...T LAMP CR or ADR LQDT LAMP CR Answer If everything was ok with the command the converter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer...

Страница 68: ...address range 0 to 63 is allowed RESULTDEC is the 8 bit answer value of the DALI bus as decimal number RESULTHEX is the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY CONTE...

Страница 69: ...CONTENT SP DTR2 LAMP CR or ADR LAMP SP QUERY SP CONTENT SP DTR2 LAMP CR Host short version LQCD2 LAMP CR or ADR LQCD2 LAMP CR Answer If everything was ok with the command the converter answers with OK...

Страница 70: ...RR SYNTAX SP ERROR CR LAMP represents the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed RESULTDEC is the 8 bit answer value of the DALI b...

Страница 71: ...CR 255 OK 1 85 0x55CR 7 96 Do QUERY MAXIMUM LEVEL in a single lamp This command reads out with the DALI command QUERY MAXIMUM LEVEL the brightness level which is used by the lamp as a maximum brightne...

Страница 72: ...th OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the c...

Страница 73: ...rn value represents a brightness value between 0 and 254 This brightness level is used in case of a power on by the lamp If there is no lamp on the DALI bus the return value will be 9 99 0x63 Timeout...

Страница 74: ...everything was ok with the command the converter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the con...

Страница 75: ...the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY FADE TIME FADE RATE in lamp 47 LAMP QUERY FADE TIME FFADE RATE 47CR OK 1 7 0x7CR The return value is an 8 bit value repres...

Страница 76: ...ALI command QUERY GROUPS 0 7 the current participation to the groups 0 to 7 for the selected lamp The DALI standard supports 64 lamps Host long version LAMP SP QUERY SP GROUPS SP 0 7 LAMP CR or ADR LA...

Страница 77: ...erter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR...

Страница 78: ...iderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 8 MODBUS register description 8 1 Overview Register Group Functi...

Страница 79: ...erhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 8 2 MODBUS Register Be aware that this manual indexes the MODBUS r...

Страница 80: ...he standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more detailed information p...

Страница 81: ...ording to the standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more detailed in...

Страница 82: ...Note According to the standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more det...

Страница 83: ...register Then send the INITIALIZE command Write 0xA500 to this register 4x00543 because the command hast to be transmitted twice within 100ms Now send START PHSICAL SELECTON command Write 0xBD00 to th...

Страница 84: ...s register The status register indicates the status of the DALI bus Under normal conditions this MODBUS register is not used read only holding register 4x00551 factory settings 15 14 13 12 11 10 9 8 7...

Страница 85: ...abe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte...

Страница 86: ...nterteilung oder GM Eintragung 8 2 10 MODBUS address READ WRITE holding register 4x65222 factory settings 255 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MODBUSADR bit description MODBUSADR Modbus address d...

Страница 87: ...Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehal...

Страница 88: ...ighter If the lamp was switched off it stays switched off 4 0x04h STEP DOWN Lamp switches one step darker As soon as the lower brightness threshold level is reached the lamp stays at this value 5 0x05...

Страница 89: ...ores the actual register value DTR as fade time for lamp 47 0x2Fh STORE DTR AS FADE RATE Stores the actual register value DTR as fade rate for lamp 64 79 0x40h 0x4F STORE DTR AS SCENE Stores the actua...

Отзывы: