Table 4—Filter Retainer (In.)
FURNACE
CASING WIDTH
FILTER SIZE
AND QUANTITY
D
14-3/16
(2) 14 X 20 X 1
14-3/8
17-1/2
(2) 14 X 20 X 1
13-3/8
21
(2) 16 X 20 X 1
11-5/8
24-1/2
(2) 16 X 20 X 1
10-1/4
PROCEDURE 7—GAS PIPING
Gas piping must be installed in accordance with national and local codes. Refer to the current edition of the NFGC.
Canadian installations must be installed in accordance with NSCNGPIC and all authorities having jurisdiction.
The gas supply line should be a separate line directly from the meter to the furnace, if possible. Refer to Table 5 for recommended gas pipe sizing.
Risers should be used to connect to the furnace and to the meter.
Fig. 8—Horizontal Filter Arrangement
A82173
FIELD-SUPPLIED
FILTER RETAINERS
AIRFLOW
D
12
″
4
″
Fig. 9—Downflow Filter Arrangement
A88486
RETURN-AIR
PLENUM
AIRFLOW
ACCESS DOOR
INSTALLATION
POSITION
OF FILTERS
—9—