Energy storage integrated machine

Safety precautions

-5-

Single PV string cannot connect to muti-inverters

One battery bank cannot be connected to muti-inverters

Inverters do not support three-phase operation

Содержание NIUESS

Страница 1: ...RePower Technology Co Ltd Energy Storage System User manual...

Страница 2: ...tallation operation and maintenance to ensure correct use and high performance of operation on the machine The use of the energy storage system must comply with local laws and regulations on grid tied...

Страница 3: ...egrated machine 11 4 Installation 12 4 1 Unpacking confirmation 12 4 2 Preparation before installation 14 4 2 1 Installation tools 14 4 3 Electrical connection 16 4 3 1 Battery connection 17 4 3 2 PV...

Страница 4: ...Energy storage integrated machine Content 5 3 2 Instruction for setup parameter 27 5 3 3 Inverter data display 29 6 Fault code 30...

Страница 5: ...Statement Our company shall not be liable for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in th...

Страница 6: ...is manual Sign Name Description Abbreviation Danger Danger Serious physical injury or even death may occur if related requirements are not followed Warning Warning Physical injury or damage to the dev...

Страница 7: ...lectrical standards Do not touch the housing of the machine or the radiator to avoid scald as they may become hot during operation Ground with proper technical before operation Do not open the surface...

Страница 8: ...rgy storage integrated machine Safety precautions 5 Single PV string cannot connect to muti inverters One battery bank cannot be connected to muti inverters Inverters do not support three phase operat...

Страница 9: ...Energy storage integrated machine Safety precautions 6 Back up cannot connect in parallel On grid or back up side cannot connect any ac generator...

Страница 10: ...se to flammable or explosive materials Do not install the machine in a place where children and ottier people can easily touch it lb avoid a risk of electric shock please remove rings bracelets and ot...

Страница 11: ...rn non professionals to enter or use fence for isolation Before carrying out any maintenance operations all input power to the machine must be disconnected first and wait for at least 5 minutes until...

Страница 12: ...hapter mainly describes the appearance packaging accessories and other information of energy storage integrated machines 2 1 Energy storage system Figure 2 1 Energy storage system Symbol Description A...

Страница 13: ...egrated machine Product overview 7 2 2 Product appearance Figure 2 2 Appearance of RESS 5000 A of the all in one energy storage machine Figure 2 3 Appearance of inverter module of the all in one energ...

Страница 14: ...COMM DRM COMM DRM communication port 3 Fan Cooling fan 4 PV connection terminal block PV DC input terminal of the inverter 5 RS485 3 RS485 3 communication port 6 RS485 1 2 RS485 1 2 communication port...

Страница 15: ...e phase energy storage integrated machine 3kW 3000 Note Technical parameters of the energy storage integrated machine refers to appendix 2 4 Dimensions and weight Figure 2 4 Dimensions of the energy s...

Страница 16: ...n and dry place and prevent the erosion of dust and water vapor The storage temperature should be kept at 20 C 60 C and the relative humidity should be kept at 4 RH 100 RH Keep away from chemically co...

Страница 17: ...he idled machine in its original package and take anti moisture and anti dust measures After taking the machine out of the box check the following items Confirm the main body of the machine is intact...

Страница 18: ...tity remarks A 3 kW 5 kW energy storage integrated machine cabinet 1 B communication connector 2 C RS485 communication connector 1 D DRMO communication connector 1 E RS485 Communication link 1 F RJ45...

Страница 19: ...Energy storage integrated machine Installation 13 4 2 Preparation before installation 4 2 1 Installation tools...

Страница 20: ...d machine Installation 14 Figure 4 2 Installation spacing unit IN In order to ensure good ventilation of the energy storage integrated machine please reserve enough installation spacing around the mac...

Страница 21: ...ote Should not be installed in direct sunlight rain snow cover and other places 4 3 Electrical connection This section introduces the detailed contents and safety precautions related to electrical con...

Страница 22: ...arried out by professional technicians as wrong operation may cause damage to the device physical injuries or even death during system operation All the electrical installation must conform to the nat...

Страница 23: ...rgy storage integrated machine do not use other connection devices without authorization from our company otherwise damage to the device unstable operation or fire may occur and our company will not u...

Страница 24: ...ation resistance of the PV panel to the ground should be greater than the safety regulation otherwise there will be electrical hazards Figure 4 4 PV wire stripping length and crimping PV and PV termin...

Страница 25: ...must be taken in accordance with the local electrical safety regulations The PE cable grounding cable of the machine must be reliably grounded Connect the three wires L N and PE of the single phase pu...

Страница 26: ...4 4 3 Definition of CAN interface pin in the battery Figure 4 7 CAN communication 1 2 3 4 5 6 7 8 GND CANH CANL 4 4 4 Definition of CAN2 interface pm in the energy storage inverter Figure 4 8 CAN2 co...

Страница 27: ...our company s WIFI and GPRS communication It can realize local monitoring remote monitoring as well as mobile APP monitoring The RS 485 communication interface of our energy storage integrated machin...

Страница 28: ...munication Pin definition 1 5VDC 2 A RS3485 3 B RS3485 4 GND Users can select RS 485 1 2 3 to communicate during RS 485 communication If selecting our company s WIFI and GPRS for monitoring users only...

Страница 29: ...nergy storage integrated machine Pin definition 1 DRM1 5 2 DRM2 6 3 DRM3 7 4 CT 5 CT 6 BAT_NTC1 7 BAT_NTC2 8 DRM4 8 9 REF 10 NC 11 NC 12 COM Detail instructions 1 Pin1 Pin2 Pin3 Pin8 Pin9 Pin12 are us...

Страница 30: ...Icon instruction Icon Instruction PV information displaying parameters related to PV panel such as PV voltage current power etc Inverter data display and parameter setting Grid information displaying...

Страница 31: ...Energy storage integrated machine LCD operation instructions 24...

Страница 32: ...on 8 Monthly generation 9 Annual generation 10 Total generation Energy storage integrated machine information 1 operation 2 Alarm 3 Power curve 4 Configuration Grid information 1 Grid voltage 2 Grid c...

Страница 33: ...rent power 5 Daily consumption 6 Monthly consumption 7 Annual consumption 8 Total consumption 5 3 Parameter setup of the energy storage integrated machine 5 3 1 Parameter classification page The param...

Страница 34: ...ry protocol 1 Pylon 2 Sunwoda 3 Yinlong 4 Xstellar 5 FES 6 Olipower 7 GCL 8 DLG 9 Penghui 10 Yiwei 3 Charge voltage Charge voltage Charge voltage range 0 60 V 4 Charge current Charge current Charge vo...

Страница 35: ...ge time period 3 range 0 23 59 Charge time period 3 ends End time of charge time period 3 range 0 23 59 12 Discharge time period 3 setup Discharge time period 3 starts Start time of charge time period...

Страница 36: ...ing mode Working mode of the inverter 2 Temperature Temperature in the inverter 3 Device type 4 Production data 5 Auxiliary DSP software version no 6 Product SN 7 Grid tied standard 8 Hardware version...

Страница 37: ...ncy is higher than protection point 2 07 Ac freq Iow1 Grid frequency is lower than protection point 1 08 Ac freq Iow2 Grid frequency is lower than protection point 2 09 Ac over currhw Output hardware...

Страница 38: ...volt high Battery overvoltage 40 Battery open Battery shut down 41 Quik stop E stop 42 Pv1 over current hw PV1 hardware overcurrent 43 Pv2 over current hw PV2 hardware overcurrent 44 Bat over current...