3
Erbas Teknoloji - Reporter MX1144-DGR/B/H User Manual
1.
DESCRIPTION
Reporter MX1144 is a user friendly and a reliable device which sends you SMS text messages and calls
you in case of input alarm events, restorations, power failure (B versions) & restorations and
periodically sends heartbeat messages. It also controls your remote devices via SMS, free phone call
and DTMF phone calls.
It includes a lot of useful features like; detailed instant STATUS query, configurable SMS text
messages, configurable input delays, user defined heartbeat periods, alarm call enable/disable,
add/delete admins & users via SMS, relay activation method selection, LED indicators, replaceable
antenna and batteries (B models), IP67 water & dust protected industrial enclosure.
MX1144-DGR has:
-
4 x Digital
isolated inputs with +3…27 VDC wide range
input voltage capacity
-
4 x 10A 230VAC high-capacity relays with volt-free NO/NC/COM pins
-
Battery back-up feature for Power Failure feature (B version only)
-
8 admin nr capacity
-
20 user nr capacity for standard version / 1.000 user nr (H version only) for remote relay control
purposes
Below list shows the alert events from your device:
-
Port1 High
:
Text Message and (optional) phone call ring
-
Port1 Low
:
Text Message and (optional) phone call ring
-
Port2 High
:
Text Message and (optional) phone call ring
-
Port2 Low
:
Text Message and (optional) phone call ring
-
Port3 High
:
Text Message and (optional) phone call ring
-
Port3 Low
:
Text Message and (optional) phone call ring
-
Port4 High
:
Text Message and (optional) phone call ring
-
Port4 Low
:
Text Message and (optional) phone call ring
-
Power Failure
:
Detailed Text Message * and (optional) phone call ring
-
Power Restored
:
Detailed Text Message *
-
Keep Alive
:
Detailed Text Message *
-
Status
:
Detailed Text Message *
* Detailed text message includes: All inputs status, all outputs status, Call mode selection, Alarm
call configuration, Keep alive period and CSQ GSM signal level in dBi.
MX144-DGR/B/H can operate in below power options:
-
External power & battery used together (B versions): In this case power failure function could be
used as well as all other functions
-
External power -only use: In this case Power failure function will not work. Others functions will
remain working
Note that Reporter devices do
not have “voice record” function, so phone calls are used for only ringing
your mobile phone. There is no voice call.
Only a local 850/900/1800/1900 MHz GSM SIM card is required to operate the device. SMS and Call
function is enough for SIM Card. Data or GPRS functions are not required.
Reporter devices switch to ultra-low power consumption mode in case of power failure. Further to this
feature; device de-attaches itself from GSM network in standby, for saving battery life. If you try to call or