background image

Erbas Teknoloji - Reporter LX1148-DGR/B/H User Manual 

 

 

 

 

 

USER MANUAL 

LX1148-DGR-rev1.03-1021 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LX1148-DGR/B/H 

GSM SMS ALARM & CONTROLLER

 

www.erbasteknoloji.com 

 

ERBAŞ 

TEKNOLOJİ

 

         Innovative Solutions 

 

Содержание LX1148-DGR

Страница 1: ...1 Erbas Teknoloji Reporter LX1148 DGR B H User Manual USER MANUAL LX1148 DGR rev1 03 1021 LX1148 DGR B H GSM SMS ALARM CONTROLLER www erbasteknoloji com ERBAŞ TEKNOLOJİ Innovative Solutions ...

Страница 2: ... remote devices via SMS and phone calls Other usages are not permitted Police fire or healthcare emergency call lines are not permitted to call directly from this device Do not configure emergency call numbers into this device BATTERY RECYCLING CR123A Lithium batteries are classified as recycled batteries Please take your empty batteries to a nearest collection point BATTERY LIFE Battery life anno...

Страница 3: ...igh Text Message and optional phone call ring Port2 Low Text Message and optional phone call ring Port3 High Text Message and optional phone call ring Port3 Low Text Message and optional phone call ring Port4 High Text Message and optional phone call ring Port4 Low Text Message and optional phone call ring Power Failure Detailed Text Message and optional phone call ring Device Activated Detailed T...

Страница 4: ... plant etc Different kinds of motors and machines and much more As soon as integrated relay power is suitable up to 10A 240VAC any kind of device machine system could be controlled with this device In some cases where required switching power is higher than the device capacity then it can still control those devices by some additional high capacity switching equipment i e contactors 2 2 Input Moni...

Страница 5: ...l Mount Firstly unscrew the Cover Fitting screws and then open the top cover If you want to mount your device to the wall Place device to the wall Point Wall Mount screwing holes shown below to the wall Drill the wall from pointed places Insert fixing plugs into the drilled points Screw in the wall mount screws from the screwing points of the device ...

Страница 6: ...l if you require services should be active on the SIM However Data Internet GPRS services are not required Before inserting the SIM card try it with a mobile phone And then o Disable PIN code protection o Send an SMS to a mobile number for testing o Call a mobile phone number for testing After above steps completed open the screws And insert SIM card into the device by pushing it as shown in below...

Страница 7: ...e of power failure feature is required Make sure you followed correct polarity of the batteries You will see indications on the board 4 4 Connect Power Note Wires should pass into the holes of the bottom cover Please check Wiring Diagram Connect 12V DC power supply into terminal block 12V positive and GND negative ground Two pieces of 12V and two pieces of GND pins are internally parallel Please n...

Страница 8: ...x for y secs RLYx y 0 99 secs ADMIN USER SMS message format is Password space Command1 space Command2 space Command3 Examples 1111 ADDA 901234567890 Adds an Admin 1111 PASS 4567 CALL ON Changes password to 4567 activates calls 4567 ADDU 44111111111 ADDU 44222222222 Adds two users by using last password 4567 RLY3 5 Turns ON RLY3 for 5 secs and then turns OFF 4567 RLYALL OFF Turns OFF all relays 5 1...

Страница 9: ... Password must be always different than 1111 5 3 Register Add User s Note Total 20 1 000 for H models people can be added as User Authorization Admins only Format Password space ADDU Number Example 1111 ADDU 901234512345 Responses Process Succeed format password is correct Process Failed format is wrong Record Succeed Memory Full record done but now memory is full Record Failed Memory Full cannot ...

Страница 10: ... trigger RLY1 in a predefined period default 2 seconds When you call device it will reject the call after a few rings Then it will Turn ON RLY1 for predefined period and it will Turn OFF RLY1 after this period If this mode is selected MOD2 will be disabled MOD2 is used to Turn ON Turn OFF all available Relays individually via DTMF Call Dial Service When you call device it will pick up and wait you...

Страница 11: ...essary alerts and create the alert in case it left open for at least 1 minute Reporter allows you to set these delays on each input individually Also low to high and high to low events could be set individually as well Authorization Admins only Format Password space INPHx Period Password space INPLx Period Examples 1111 INPH2 60 Input2 High alarm delay is 60 secs 1111 INPL2 0 Input2 Low alarm dela...

Страница 12: ...owered you may send a Status Query SMS to Reporter It will reply to you with detailed current I O status some settings and GSM signal level information Authorization Admins only Format Password space STATUS Examples 1111 STATUS ask status Responses INP1 OFF INP1 is OFF LOW INP4 ON INP4 is ON HIGH RLY1 OFF RLY1 is OFF LOW RLY8 ON RLY8 is ON HIGH MOD 1 call mode is MOD1 trigger mode CALL OFF alert c...

Страница 13: ... Call DTMF Dial Method MOD2 MOD2 is used to Turn ON Turn OFF all available Relays individually via DTMF Call Dial Service When you call device it will hang up and wait you dial Relay Nr and dial for ON OFF If your dials are not detected properly please make sure you disabled VoLTE feature from your mobile phone settings usually under Cellular Options Voice Data VoLTE If you still have problems ple...

Страница 14: ...iMessage I don t receive power failure SMS notifications Version not suitable Only B versions have this function Batteries not inserted or died Insert replace fresh batteries Alarm occurred I received SMS but I didn t receive a Call Call feature not activated Check Alert Calls Activate instructions SIM card Call service not activated Contact SIM card provider Alarm occurred I received Call but did...

Страница 15: ...ge Events SMS Call Power Up SMS Call Power Failure B versions only SMS for Low Battery SMS for Keep Alive Messages SMS for Status Query Relay Control Modes SMS Call Trigger MOD1 Call DTMF Dial MOD2 Admin User Capacity 8 Admins 20 Users 1 000 users for H versions Configurations via SMS Change password Add delete admins and users Activate deactivate alert Call function Set call control modes Set inp...

Страница 16: ...16 Erbas Teknoloji Reporter LX1148 DGR B H User Manual 10 NOTES Device Phone Number Admin Numbers User Numbers Made in Türkiye ...