REO REOVIB SMW 4000 Скачать руководство пользователя страница 4

REOVIB SWM 4000  
Operating Instructions 

 

 
1.0 General 

Reliable and accurate instrument for the installation, testing and servicing of vibratory conveyor equip-
ment. This unit supersedes REO‘s popular SMW3000 unit and incorporates many new features. When 
combined with an appropriate accelerometer, the unit displays, acceleration, speed, vibration amplitude 
and frequency. It can store up to 40 instantaneous values and transfer these as an .XLS file to a PC via 
USB connection. The language may be set to allow worldwide use and the screen is backlit to allow easy 
viewing in all ambient conditions. The unit is housed within a robust rubber casing and the integrated 
lithium-ion battery, can be charged easily via a USB interface to allow versatile operation. Optimization of 
the design, display and internal battery, means that the unit is faster, more reliable and yet is smaller and 
more convenient to use. The REOVIB SMW4000 instrument is supplied with a comprehensive list of 
accessories, consisting of USB cable and charger (traveler), protective cover, 100mV/g accelerometer, 
sensor mounting bracket and sturdy carry case. 
 
2.0 Technical Data 

 
Unit type 

REOVIB SWM 4000 

Supply voltage 

USB Travel Charger / Power Supply,  
115/230V , 50/60 Hz , +/-10% min. 0,9A / 5V 

Effective value input  

Sensor 10 / 100 / 500 mV/g   +/-20% difference adjustment (8 – 600mV/g) 

Sensor supply 

Constant current 14mA 

Frequency 

6...600Hz 

Amplitude 

0...30mm 

Measuring range 

0,2...150g 

Measuring error  

1,5% 

Enclosure protection  

IP 40 

Dimensions- (HxWxD) 

81 x 159,5 x 35 mm 

Operating temperature 

0...45 °C 

Storage temperature 

-20...+45 °C 

Rel. Humidity 

93 % without dew or condensation 

Environment protection  

Class 1 (IEC 664) 

Power rating 

0,8 VA 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание REOVIB SMW 4000

Страница 1: ...6774_EN_ANL_rev00 DOC 23 12 2014 REOVIB For Vibratory Feeder Systems SWM 4000 Handheld measuring instrument for vibratory feeder ...

Страница 2: ...ure 6 5 0 Mounting the accelerometer 7 6 0 Calibrating the sensor input 7 7 0 Saving the measured values 7 8 0 Read measurements 7 9 0 Saving your own parameter 8 10 0 Function only measure or enable and disable Parameter Menues 8 11 0 Factory setting 8 12 0 Readout the saved data sets into a PC 8 13 0 Delivery contents 9 14 0 Spare Parts Single components 9 15 0 Dimensions 10 ...

Страница 3: ...nal safety of operators and also for the protection of the described product and connected equipment Warning Hazardous Voltage Failure to observe can kill cause serious injury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Bef...

Страница 4: ...low versatile operation Optimization of the design display and internal battery means that the unit is faster more reliable and yet is smaller and more convenient to use The REOVIB SMW4000 instrument is supplied with a comprehensive list of accessories consisting of USB cable and charger traveler protective cover 100mV g accelerometer sensor mounting bracket and sturdy carry case 2 0 Technical Dat...

Страница 5: ...level or return to Operation mode 5 6 7 Select menu Open Close Menu Select parameters 1 Indicates that the Sensor is not connected or Sensor fault blinking Acceleration g Speed cm s Deflection mm Frequency Hz Acceleration g Speed cm s Deflection mm Frequency Hz I 0 P P P 1 Info Records Service Storage black background Selected menu parameters 2 Acceleration 5 00 g Speed 7 5 cm s Deflection 0 23 mm...

Страница 6: ... Acceleration sensor calibration 8 600 mV g 4 3 Language Select the menu language wählen 4 4 Multi Line Changing the menu structure Multi Line Sin gle Line 1 0 4 5 Back Light Backlight off on 1 0 4 6 Factory Settings Restoring factory settings Execute 4 7 Code Menus enabling or disabling see section 9 0 and 10 0 4 8 User Params Load customers parameter settings Execute 4 9 STOP Auto Off Auto Off 1...

Страница 7: ...or supplied This certificate shows the exact value of the sensor output voltage for example 95 mV g This value must be entered in the Menu Service with Parameter Cal The sensor input is factory set to 100 mV g It is possible to set deviations up to 20 7 0 Saving the measured values All four values acceleration speed deflection amplitude frequency are saved Press the arrow key to select the no of t...

Страница 8: ...Parameter Code 117 Lock Menues 1 Enabling parameter Menus In Menu Service Parameter Code 117 Lock Menues 0 11 0 Factory setting With this parameter you can restore the factory settings In Menu Service Parameter Factory Settings 12 0 Readout the saved data sets into a PC At this unit it is possible to load the saved data sets via the USB interface into a PC For the coupling you need Microsoft EXCEL...

Страница 9: ...000 Sturdy carry case Sensor mounting bracket Accelerometer 100mv g incl mounting magnet 14 0 Spare Parts Single components Designation Order Number Measuring instrument SWM 4000 with USB charger power Supply traveler incl USB da ta charging cable 677411 USB charger power Supply traveler incl USB data charging cable 090611 Silicone protective cover for SWM 4000 090612 Sturdy carry case 090613 Sens...

Страница 10: ...REOVIB SWM 4000 Operating Instructions 10 15 0 Dimensions ...

Страница 11: ...REOVIB SWM 4000 Operating Instructions 11 ...

Страница 12: ...reo ag in Italy REO ITALIA S r l Via Treponti 29 I 25086 Rezzato BS Tel 39 030 279 3883 Fax 39 030 279 0600 E Mail info reoitalia it Internet www reoitalia it Poland REO CROMA Sp zo o ul Pozaryskiego 28 bud 20 PL 04 703 Warszawa Tel 48 0 22 812 3066 Fax 48 0 22 815 6906 E Mail croma croma com pl Internet www croma com pl Spain REO ESPAÑA 2002 S A C Manuel Ventura i Campeny 21B local 9 E 08339 Vila...

Отзывы: