REOVIB SWM 4000  
Operating Instructions 

 

 

 

 

Technical Information for the User 

 
 
This  description  contains  the  necessary  information  for  the  correct  application  of  the  product  described 
below. It is intended for use by technically qualified personnel. 
Qualified personnel are persons who, because of their training,  experience and  position  as  well as their 
knowledge of appropriate standards, regulations, health and safety requirements and working conditions, 
are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their nor-
mal duties and are therefore aware of, and can report, possible hazards (Definition of specialist according 
to IEC 364). 
 

Safety Instructions

 

The following instructions are provided for the personal safety of operators and also for the protection of 
the described product and connected equipment. 

 

Warning! 

Hazardous Voltage 
Failure to observe can kill, cause serious injury or damage 

 

    Isolate  from  mains  before  installation  or  dismantling  work,  as  well  as  for  fuse  changes  or  post 

  installation modifications. 

    Observe the prescribed accident prevention and safety rules for the specific application. 

    Before putting into operation check if the rated voltage for the unit conforms with the local  

  supply voltage. 

    Emergency stop devices must be provided for all applications. Operation of the emergency   

  stop must inhibit any further uncontrolled operation. 

    Electrical connections must be covered 

    Earth bonding must be tested prior to operation 

 

Prescribed Use 

The units described herein are electrically powered for use in industrial applications and are not suitable 
for domestic use 
 
 These units comply with Directive 2004/108/EC 

EMC Directive    

 

!

 

 

RoHS

COMPLAINT

Содержание REOVIB SMW 4000

Страница 1: ...6774_EN_ANL_rev00 DOC 23 12 2014 REOVIB For Vibratory Feeder Systems SWM 4000 Handheld measuring instrument for vibratory feeder ...

Страница 2: ...ure 6 5 0 Mounting the accelerometer 7 6 0 Calibrating the sensor input 7 7 0 Saving the measured values 7 8 0 Read measurements 7 9 0 Saving your own parameter 8 10 0 Function only measure or enable and disable Parameter Menues 8 11 0 Factory setting 8 12 0 Readout the saved data sets into a PC 8 13 0 Delivery contents 9 14 0 Spare Parts Single components 9 15 0 Dimensions 10 ...

Страница 3: ...nal safety of operators and also for the protection of the described product and connected equipment Warning Hazardous Voltage Failure to observe can kill cause serious injury or damage Isolate from mains before installation or dismantling work as well as for fuse changes or post installation modifications Observe the prescribed accident prevention and safety rules for the specific application Bef...

Страница 4: ...low versatile operation Optimization of the design display and internal battery means that the unit is faster more reliable and yet is smaller and more convenient to use The REOVIB SMW4000 instrument is supplied with a comprehensive list of accessories consisting of USB cable and charger traveler protective cover 100mV g accelerometer sensor mounting bracket and sturdy carry case 2 0 Technical Dat...

Страница 5: ...level or return to Operation mode 5 6 7 Select menu Open Close Menu Select parameters 1 Indicates that the Sensor is not connected or Sensor fault blinking Acceleration g Speed cm s Deflection mm Frequency Hz Acceleration g Speed cm s Deflection mm Frequency Hz I 0 P P P 1 Info Records Service Storage black background Selected menu parameters 2 Acceleration 5 00 g Speed 7 5 cm s Deflection 0 23 mm...

Страница 6: ... Acceleration sensor calibration 8 600 mV g 4 3 Language Select the menu language wählen 4 4 Multi Line Changing the menu structure Multi Line Sin gle Line 1 0 4 5 Back Light Backlight off on 1 0 4 6 Factory Settings Restoring factory settings Execute 4 7 Code Menus enabling or disabling see section 9 0 and 10 0 4 8 User Params Load customers parameter settings Execute 4 9 STOP Auto Off Auto Off 1...

Страница 7: ...or supplied This certificate shows the exact value of the sensor output voltage for example 95 mV g This value must be entered in the Menu Service with Parameter Cal The sensor input is factory set to 100 mV g It is possible to set deviations up to 20 7 0 Saving the measured values All four values acceleration speed deflection amplitude frequency are saved Press the arrow key to select the no of t...

Страница 8: ...Parameter Code 117 Lock Menues 1 Enabling parameter Menus In Menu Service Parameter Code 117 Lock Menues 0 11 0 Factory setting With this parameter you can restore the factory settings In Menu Service Parameter Factory Settings 12 0 Readout the saved data sets into a PC At this unit it is possible to load the saved data sets via the USB interface into a PC For the coupling you need Microsoft EXCEL...

Страница 9: ...000 Sturdy carry case Sensor mounting bracket Accelerometer 100mv g incl mounting magnet 14 0 Spare Parts Single components Designation Order Number Measuring instrument SWM 4000 with USB charger power Supply traveler incl USB da ta charging cable 677411 USB charger power Supply traveler incl USB data charging cable 090611 Silicone protective cover for SWM 4000 090612 Sturdy carry case 090613 Sens...

Страница 10: ...REOVIB SWM 4000 Operating Instructions 10 15 0 Dimensions ...

Страница 11: ...REOVIB SWM 4000 Operating Instructions 11 ...

Страница 12: ...reo ag in Italy REO ITALIA S r l Via Treponti 29 I 25086 Rezzato BS Tel 39 030 279 3883 Fax 39 030 279 0600 E Mail info reoitalia it Internet www reoitalia it Poland REO CROMA Sp zo o ul Pozaryskiego 28 bud 20 PL 04 703 Warszawa Tel 48 0 22 812 3066 Fax 48 0 22 815 6906 E Mail croma croma com pl Internet www croma com pl Spain REO ESPAÑA 2002 S A C Manuel Ventura i Campeny 21B local 9 E 08339 Vila...

Отзывы: