EN
99
7.2.1.4 • Temperature (for bypass-function)
In this menu you can set the minimal comfort temperature of the room where the Endura
®
Twist is situated. This temperature setting determines whether or not the Endura
®
Twist will
alternate and as such if the inlet air will be either preheated or not.
Example:
- Whenever the outdoor air is much cooler than the indoor temperature and the indoor
temperature exceeds the comfort temperature, then the cool outdoor air will be blown in
directly into the room without preheating in order to have a cooling effect.
- Whenever the outdoor air is much warmer than the indoor temperature, the outdoor
temperature will be blown in directly into the room without warmth recuperation in order
to have a warming effect.
- Whenever there aren’t any remarkable differences between the indoor and outdoor
temperature, the Endura
®
Twist will alternate and preheat the inlet air with its regenerators.
- The temperature settings will follow a winter- and summer schedule. The set comfort
temperature can differ according to the season.