18
2. Parameter Set
5. Chg Limit Volt: User can set the charge controller’s
maximum charging Voltage
6. Equa Volt: User can set the Equalization Voltage
7. Boost Volt: User can set the Boost Voltage
8. Float Volt: User can set the Float Voltage
9. Boost Return Volt: User can set the Boost Return
Voltage (Voltage when charge controller will re-enter
boost stage.
10. Batt LVR: User can set Low Voltage Reconnect
11. Batt UVW: User can set Under Voltage Warning
12. Batt LVW: User can set Low Voltage Warning
13. EquaChg Time: User can set Equalization time
14. Boost Chg Time: User can set Boost time
15. Equa INV: User can set Equalization interval
16. Temp Comp: User can set Temperature compensation
1. Sys Batt Volt: User can change between
(Auto/12V/24V/36V/48V)
2. Batt Type: User can change between Sealed (SLD),
Gel, Flooded (FLD), Lithium (Li) and User (USE)
3. Battery Capacity: User can set battery bank’s Amp
hour capacity
4. Batt OVD: User can set battery over voltage disconnect
1.Sys Batt Volt: AUTO(12V)
2.Batt Type: SLD
3.Batt Capacity: 200
4.Batt OVD: 16.0V
5.Chg Limit Volt: 15.5V
6.Equa Volt: 14.6V
7.Boost Volt: 14.4V
8.Float Volt: 13.8V
13.Equa Chg Time: 120MIN
14.Boost Chg time: 120MIN
15.Equa INV: 30D
16.Temp Comp:
-3mV/℃/2V
9.Boost Return Volt: 13.2V
10.Batt LVR: 12.6V
11.Batt UVW: 12.0V
12.Batt LVW: 11.1V
Содержание Rover 100A
Страница 1: ...Rover 100A Version 1 4 Maximum Power Point Tracking Solar Charge Controller ROVER SERIES ...
Страница 12: ...1 Remove Cover 2 Connect Battery 3 Connect Solar Panels 11 ...
Страница 34: ...3 48 Volt System Conversion Efficiency 2 24 Volt System Conversion Efficiency 33 ...
Страница 35: ...34 NOTE Dimensions in millimeters mm Dimensions 443 320 270 280 4Xφ8 4Xφ12 110 50 ...