34
NOTE
By Default, User mode operates as a 48V LFP (16S) battery profile. Each
parameter can be individually adjusted to adjust the profile to a 48V User Lithium
Charge Profile or a 48V User Non-Lithium Charger Profile.
NOTE
36V LFP (12S) and 48V LFP (15S) can only adjust the Boost Voltage. Once
adjusted, the remaining parameters will adjust and synchronize automatically.
1. 48V User Lithium batteries will need to indicate the same charging voltage for
"Equalization", "Boost Voltage", and "Float Voltage" as the logic will then understand this to
mean Lithium.
2. 48V User Non-Lithium batteries will need to indicate different charging voltage for
"Equalization", "Boost Voltage", and "Float Voltage" and will not support functions such as
Lithium activation function and low temperature heating function;
The User parameters are assumed to be 77°F /25
℃
/ in 12V system parameters. For 36V
systems multiply the parameters × 3, 48V systems multiply the parameters × 4.
Users responsibility to match battery spec.
User error will not be covered in warranty claim.