87
Programming examples:
1. Example: Access via transponder
(Reading transponder)
(a) (b) (c) (d) (e)
(a) Output #1 is to be switched
(b) Access only via transponder
(c) Memory slot number "000" (output #1 can use: 000 - 999)
(d) Hold transponder in front of the sensor surface (distance < 2 cm)
(e) Save programming (code lock emits two beeps)
(Reading transponder)
(a) (b) (c) (d) (e)
(a) Output #2 is to be switched
(b) Access only via transponder
(c) Memory slot number "027" (output #2 can use: 001 - 100)
(d) Hold transponder in front of the sensor surface (distance < 2 cm)
(e) Save programming (code lock emits two beeps)
While the code lock is in regular operation (not in programming mode!), output #1 or
#2 (depending on programming) are switched by holding a valid transponder in front
of the sensor surface at the bottom of the code lock.
The distance should be less than approx. 2 cm, so that the code lock can recognise
the transponder. No input of a code is required.