• Fully reinsert the dry dust filter frame into the dehumidifier; it cannot be inserted
correctly if it is not positioned properly.
Troubleshooting
Problem
Possible cause
Suggested solution
The machine does not
start
Is the power cable
plugged in?
The machine is not
working; a red LED
is on.
Is the water tank full or
not inserted properly?
Empty container and insert
fully. The float switch (6)
on the container must be
closed.
The machine is not
working.
Is the room temperature
over 35 °C or under
5 °C?
Is the humidity in the
room already very low?
The safety thermostat
disables operation at
temperatures above or
below these limits. Wait until
the temperature changes to
a level at which operation is
permitted.
The room is not being
dehumidified properly.
Is the room too big
for the rating of the
machine?
Are the ventilation
grilles blocked? Are the
air inlets or dust filter
blocked/dirty?
Remove the blocking objects,
clean the dust filter.
The dehumidifier is loud
during operation.
Not stable enough, is it
unstable or slanting?
Place the dehumidifier on a
horizontal, stable and even
surface.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.
Technical Data
Operating voltage
................................
220 - 240 V/AC, 50Hz
Power consumption............................
max. 280 W
Protection rating
.................................
IP21
Cable length
.........................................150 cm
Room size
.............................................
max. 32 m
2
Noise level
............................................
47 dB(A)
Water tank volume
..............................2.8 l
Coolant/quantity
..................................
R134a / 135 g
Air flow rate
.........................................
max. 210 m
3
/h
Dehumidifying output
.........................
About 16 l/24 hours (at a room temperature of
30 °C / 80% relative humidity)
Operating conditions
..........................
+5 to +35 °C, 40 - 90 % RH
Storage conditions
..............................
+5 to +40 °C, 30 - 90 % RH
Dimensions (W x H x D)
......................
310 x 543 x 230 mm
Weight
...................................................
11.5 kg
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright
2014
by Conrad Electronic SE.
V1_0814_02-DS