34
Only these phone numbers will receive an alarm text message.
The phone numbers must be entered in international format. The phone number
0172xxxxx therefore turns into +49172xxxxx.
These phone numbers are also required for the function INCALL (if activa
-
ted).
Which sensors are to trigger an alarm and what is deemed an alarm?
SET SHOCK 10 #1513
10 = maximum sensitivity (slight tapping), 1 = insensitive
SET SHOCK 8 3 #1513
A shock of level 8 must continue for at least 3 seconds.
SET SHOCK 5 10 INV #1513
A shock of level 5 must be gone for 10 seconds.
SET LIGHT #1513
The sensor measures the current light strength and adjusts it to just AVOID the alarm.
SET LIGHT 10 #1513
10 = maximum sensitivity (slight light irradiation), 1 = insensitive (direct solar irradia-
tion)
SET SLOPE 45 #1513
Angle indication in degrees (here in the example: 45°), when receiving the text message,
the current position is stored as the zero position.
The measurement takes place along the housing edges; each axis (housing edge) is
measured separately.
The alarm is triggered once the housing is turned across one axis beyond the set
angle.
The indication in „TEST STATUS #1513“ of the angle (axis/housing edge) is the one with
the highest value.