7
TONiC RSLM20/RELM20 Functional Safety installation guide and safety manual Original instructions
Measuring lengths
Dimensions and tolerances in mm
20
ML = (L − 10) without limits
Measuring length, ML = (L − 25) with dual 10 mm limits
Optical centreline
(incremental and reference mark)
2.1 ±0.15
5
7.8
Ra 3.2
0.05
F
F = axis of motion
5
Limit sensor position