TONiC RSLM20/RELM20 Functional Safety installation guide and safety manual           Original instructions

Alarm asserted when: 
– Signal amplitude <20% or >135%.

– Readhead speed too high for reliable operation.

or 3-state alarm

Differentially transmitted signals forced open 

circuit for >15 ms when alarm conditions valid.

Digital output signals (DOP only)

Form – Square wave differential line driver to EIA RS422A (except limits P and Q)

Alarm 

 

Line driven 

(Asynchronous pulse)

Limits

  Open collector output, asynchronous pulse

Repeatability <0.1 mm

Length of limit actuator

P Q

Active high or  Active low

P Q

Repeatability <0.1 mm

Length of limit actuator

Incremental 

  2 channels A and B in quadrature (90° phase shifted)

Reference 

 

Signal period

Resolution

A

B

Z

Z

Bi-directionally repeatable pulse Z, duration equal to the resolution

Bi-directionally repeatable pulse Z, duration equal to the signal period

Wide reference 

E

>15 ms

DOP set-up 

*

0

Voltage 

at X

1

100%

0

Signal level

Set-up signal voltage proportional to incremental signal amplitude

NOTE:

  Select ‘standard’ or ‘wide’ reference at time of ordering, to match the requirements of the controller being used. 

20 µm

45°

Output specifications 

Analogue output signals

Incremental

  2 channels V

1

 and V

2

 differential sinusoids in quadrature (90° phase shifted)

(V

+) − (V

−)

(V

+) − (V

−)

Bi-directionally repeatable. 
Differential pulse V

, centred on 45°.

(V

0

+) − (V

−)

Reference

0.8 to 1.2 Vpp

360° (nominal)

Limits

  Open collector output, asynchronous pulse

Ti0000 interface only

Repeatability <0.1 mm

Length of limit actuator

V

p

 V

q

T301

x

 readhead only

Active low

V

V

q

Repeatability <0.1 mm

Length of limit actuator

Active high

Ti0000 set-up 

*

Voltage  

at V

X

3.3 (nom)

0

Between 50% and 70% signal level, V

X

 is a duty cycle.

Time spent at 3.3 V increases with incremental signal level. 
At >70% signal level V

X

 is nominal 3.3 V.

NOTE:

 Ti0000 interface contains a transistor to invert the readhead’s ‘active low’ signal to give an ‘active high’ output.

Set-up signals as shown are not present during calibration routine.   

 

Inverse signals not shown for clarity.

0.7 to 1.35 Vpp with Green LED 

indication (readhead) and 120R 
termination. 

Centred on 1.65 V.

NOTE:

 DOP centred on 2.5 V.

50%   Signal level 

70%  100%

Differential signals V

0

+ and V

0

− centred on ~1.65 V

NOTE:

 DOP centred on 2.5 V. 

Содержание TONiC FS T301 Series

Страница 1: ...Installation guide M 6688 9046 02 B TONiC FS T301x RSLM20 RELM20 high accuracy linear encoder system Functional Safety installation guide and safety manual...

Страница 2: ...Cable connection 12 System connection Ti interface 12 System connection DOP interface 13 Readhead mounting and alignment 14 System calibration 15 Diagnostic LEDs 16 Output signals 17 Speed 18 Electri...

Страница 3: ...case the user will be required to correct the interference at their own expense NOTE This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to...

Страница 4: ...r own assessment of the full system to determine its safety capability Correct use includes X X Operating the TONiC FS system within the limits defined in this document X X Installing the system as de...

Страница 5: ...gnals falls within the limits defined in Evaluation unit monitoring Evaluation unit monitoring To achieve full system integrity the evaluation unit must continuously monitor the analogue outputs and i...

Страница 6: ...AHF79 The products comply with EU directives and comply with the following technical standards 2014 30 EU Electromagnetic compatibility EMC 2011 65 EU On the restriction of the use of certain hazardou...

Страница 7: ...e CH3 CH2 5CH3 Propan 2 ol CH3CHOHCH3 Scale and readhead Acetone CH3COCH3 Methylated Spirits Chlorinated Solvents Readhead only Acetone CH3COCH3 Methylated Spirits Chlorinated Solvents Scale only Mini...

Страница 8: ...2 5 0 2 5 35 23 11 5 6 min 2 mounting holes M2 5 through counterbored 3 2 3 deep both sides Set up LED CAL AGC LED 0 6 Pitch tol 1 Rideheight 2 1 0 15 Alternative mounting face 2 mounting holes M2 5...

Страница 9: ...anual Original instructions Measuring lengths Dimensions and tolerances in mm 20 ML L 10 without limits Measuring length ML L 25 with dual 10 mm limits Optical centreline incremental and reference mar...

Страница 10: ...from scale ends Double sided adhesive tape is included with all scale lengths When scale is to be mounted horizontally on a vertical surface position the dowels so that the datum edge is supported Ad...

Страница 11: ...remaining backing liner Area for RGG 2 epoxy A 9531 0342 6 Support dowels 7 Remove excess epoxy or 5 Locate scale against dowels or ledge and rotate down onto substrate Press down with firm finger pre...

Страница 12: ...concentrators on the readhead The design of the bracket should be sufficiently stiff so that it is able to tolerate such force without distorting Following the clamping instructions on the scale insta...

Страница 13: ...of travel as indicated by the readhead and interface set up LEDs readhead Green DOP interface ideally Blue Purple CALIBRATION Press and release the CAL button on the interface The CAL LED on the readh...

Страница 14: ...ween the readhead and the interface X X The customer is responsible for verifying the product function where the readhead to interface cable has been re terminated including the installation of extens...

Страница 15: ...aking care not to touch the pins plug the connector into the socket in the interface ensuring correct orientation as shown 3 Refit the cover plate ensuring the cable ferrule is located in the recess o...

Страница 16: ...arance will contribute to mechanical safe position Green Orange Red Readhead set up LED status Yaw 0 0 4 Pitch 0 1 Roll 0 0 5 Rideheight 2 1 0 15 mm DOP interface set up LED status Blue Green Orange R...

Страница 17: ...d back and forth over the selected reference mark until the CAL LED stops flashing and remains off The reference mark is now phased X X The system automatically exits the CAL routine and is ready for...

Страница 18: ...evel 50 to 70 No Red Poor set up signal may be too low for reliable operation signal level 50 No Purple blank flashing Over signal system in error Yes Blue blank flashing Over speed system in error Ye...

Страница 19: ...14 Shield Inner shield Not connected Outer shield Case Function Output type Signal Colour Power 5 V Brown 0 V White Incremental signals Analogue Cosine V1 Red Blue Sine V2 Yellow Green Reference mark...

Страница 20: ...40 2 70 1 35 0 540 0 270 0 135 0 054 0 027 25 10 10 8 10 3 24 1 62 0 810 0 324 0 162 0 081 0 032 0 016 20 10 10 6 75 2 70 1 35 0 675 0 270 0 135 0 068 0 027 0 013 12 10 9 4 50 1 80 0 900 0 450 0 180 0...

Страница 21: ...0 V 5 V Readhead IMPORTANT The outer shield must be connected to the machine earth Field Ground The inner shield must be connected to 0 V at receiving electronics only Care should be taken to ensure t...

Страница 22: ...Select standard or wide reference at time of ordering to match the requirements of the controller being used 20 m 45 Output specifications Analogue output signals Incremental 2 channels V1 and V2 diff...

Страница 23: ...rating 0 C to 70 C Sealing readhead IP40 Ti interface IP20 DOP interface IP30 Acceleration readhead Operating 500 m s 3 axes Shock system Non operating 500 m s 6 ms sine 3 axes Vibration system Operat...

Страница 24: ...20 Selectable reference marks every 200 mm RELM20 Midpoint of scale length RELE20 20 mm from end of scale Phasing Auto phased by readhead calibration routine Mounting Self adhesive backing tape Repeat...

Страница 25: ...e enable disable Push and release 3 seconds AGC enable disable Push and hold during power Off On cycle Restore factory defaults Refer to readhead LED functionality chart for set up LED indications 48...

Страница 26: ...T 2019 Renishaw plc All rights reserved Renishaw reserves the right to change specifications without notice RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renish...

Отзывы: