Renishaw RGH40 Скачать руководство пользователя страница 3

RGH40 RGS40-G

 

installation guide

1

The packaging of our products contains the following materials and can be recycled.

Packaging Component

Material

ISO 11469

Recycling Guidance

Outer box

Cardboard

Not applicable

Recyclable

Polypropylene

PP

Recyclable

Inserts

Low Density Polyethylene Foam

LDPE

Recyclable

Cardboard

Not applicable

Recyclable

Bags

High Density Polyethylene Bag

HDPE

Recyclable

Metalised Polyethylene

PE

Recyclable

Product compliance

C

Renishaw plc declares that RGH40 complies with the applicable standards and regulations.  
A copy of the EC Declaration of Conformity is available on request.

FCC compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or 
authorised representative could void the user’s authority to operate the equipment. 
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at his own expense.

NOTE:

 This unit was tested with shielded cables on the peripheral devices. Shielded cables must be  

used with the unit to ensure compliance.

RoHS compliance

Compliant with EC directive 2011/65/EU (RoHS)

Further information

Further information relating to the RGH40 encoder range can be found in the RGH40 System  
Data sheet. (L-9517- 9752) This can be downloaded from our website www.renishaw.com/encoder  
and is also available from your local representative. This document may not be copied or reproduced  
in whole or in part, transferred to any other media or language, by any means without the written  
prior permission of Renishaw. The publication of material within this document does not imply freedom 
from the patent rights of Renishaw plc.

Disclaimer

RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS 
DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES  
OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, 
HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.

The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product 
should not be mixed with general household waste upon disposal.  It is the responsibility of the end user to 
dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) 
to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent 
potential negative effects on the environment. For more information, please contact your local waste disposal 
service or Renishaw distributor.

Содержание RGH40

Страница 1: ...Installation guide M 9550 9023 01 A RGH40 RGS40 G linear encoder system...

Страница 2: ...ss scale installation drawing clip clamp mounting 6 Clip clamp mounting installation 7 Reference mark actuator installation 8 Limit switch installation 8 Readhead mounting and alignment 8 Reference ma...

Страница 3: ...tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested wi...

Страница 4: ...cal encoder scale that provides good immunity against contaminants such as dust fingerprints and light oils However in harsh environments such as machine tool applications protection should be provide...

Страница 5: ...es optical and reference mark centreline Roll tol 1 Q limit magnet A 9531 0251 Mount dimple up for Q Optional bolted limit magnet P A 9550 0047 Q A 9550 0048 Mounting ledge or top surface of bracket f...

Страница 6: ...6 5 2 9 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 ML 47 ML 44 L ML 14 5 L 25 n 1 4 9 2 9 10 12 RGG 2 2 part epoxy usually coincident with user selected scale datum Double sided adhesive tape Bolted P lim...

Страница 7: ...to cure fully then clean scale using Renishaw scle wipes A 9523 4040 or a clean dry lint free cloth Adhesive mounting installation 2 Mark area for epoxy on adhesive tape 1 RGH40 RGS40 G installation...

Страница 8: ...x 6 5 14 5 M3 x 0 5 x 6 5 23 5 0 1 34 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 5 5 Datum clamp Mounting clip 4 9 2 9 Dimensions and tolerances in mm RGS40 G glass scale installation drawing clip clamp m...

Страница 9: ...ean dry lint free cloth M 9550 0057 gap setting shim 4 Ensure scale can move so free to expand contract 1 2 mm 1 2 mm M 9550 0057 gap setting shim M 9550 0061 datum pad RGH40 RGS40 G installation guid...

Страница 10: ...able conformance to the installation tolerances allow adjustment to the rideheight of the readhead and be sufficiently stiff to prevent deflection or vibration of the readhead during operation For eas...

Страница 11: ...way D type plug L 12 way circular V 12 way circular coupling W 16 way in line connector X Power 5 V Brown 4 2 2 A Brown link 5 12 12 M 0 V White 12 10 10 B White link 13 11 11 N Incremental signals V1...

Страница 12: ...ers must ensure they comply with the lowest recommended counter input frequency Encoder velocity m s Resolution m x 4 safety factor Function Signal Colour 15 way D type plug D 16 way in line connector...

Страница 13: ...d from each other If the inner and outer shields are connected together this will cause a short between 0 V and earth which could cause electrical noise issues Electrical connections Grounding and shi...

Страница 14: ...P Resolution S A B Z Inverse signal not shown for clarity Synchronised pulse Z duration as resolution S Repeatability of position uni directional maintained within 10 C from temperature at time of pha...

Страница 15: ...ealing IP50 Acceleration Operating 500 m s2 3 axes Shock Non operating 1000 m s2 6 ms sine 3 axes Vibration Operating 100 m s2 max 55 Hz to 2000 Hz 3 axes Mass Readhead 50 g Cable 38 g m Cable 12 core...

Страница 16: ...our main website at www renishaw com contact M 9550 9023 01 RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countrie...

Отзывы: