Renishaw RGH40 Скачать руководство пользователя страница 15

RGH40 RGS40-G

 

installation guide

13

General specifications

Power supply

5 V ± 5%

RGH40A, T, D, G and X <120 mA
RGH40N, W, Y and H <150 mA

NOTE:

 Current consumption figures refer to unterminated readheads.

For digital outputs a further 35 mA per channel pair (e.g. A+, A-) will be 
drawn when terminated with 120 

Ω

.

For analogue outputs a further 20 mA will be drawn when terminated 
with 120 

Ω

.

Power from a 5 V dc supply complying with the requirements for SELV 
of standard IEC BS EN 60950-1.

Ripple

200 mVpp@frequency up to 500 kHz maximum.

Temperature

Storage

-20 °C to +70 °C

Operating

0 °C to +55 °C

Humidity

95% relative humidity (non-condensing) to EN 60068-2-78

Sealing

IP50

Acceleration

Operating

500 m/s

2

, 3 axes

Shock

Non-operating

1000 m/s

2

, 6 ms, ½ sine, 3 axes

Vibration

Operating

100 m/s

2

 max @ 55 Hz to 2000 Hz, 3 axes

Mass

Readhead

50 g

Cable

38 g/m

Cable

12 core, double shielded, outside diameter 4.5 ±0.2 mm.
Flex life >20 x 10

6

 cycles at 50 mm bend radius.

The RGH40 series readheads have been designed to the relevant EMC standards, but must be correctly 

integrated to achieve EMC compliance. In particular, attention to shielding and earthing arrangements 

 

is essential.

Scale specifications

Material

Chrome on glass

Form 

(H x W)

2.9 mm x 18 mm

Scale period

40 µm

Coefficient of thermal expansion

~

 

8.5 µm/m/°C

Mounting

Epoxy datum point and adhesive backing tape, or mechanical 
datum clamp and mounting clips

Scale length (mm)

130

180

230

280

310

400

510

760

1010

Accuracy 

(±µm)

0.7

0.9

1.1

1.3

1.4

1.8

2.2

3.2

4.2

Содержание RGH40

Страница 1: ...Installation guide M 9550 9023 01 A RGH40 RGS40 G linear encoder system...

Страница 2: ...ss scale installation drawing clip clamp mounting 6 Clip clamp mounting installation 7 Reference mark actuator installation 8 Limit switch installation 8 Readhead mounting and alignment 8 Reference ma...

Страница 3: ...tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested wi...

Страница 4: ...cal encoder scale that provides good immunity against contaminants such as dust fingerprints and light oils However in harsh environments such as machine tool applications protection should be provide...

Страница 5: ...es optical and reference mark centreline Roll tol 1 Q limit magnet A 9531 0251 Mount dimple up for Q Optional bolted limit magnet P A 9550 0047 Q A 9550 0048 Mounting ledge or top surface of bracket f...

Страница 6: ...6 5 2 9 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 ML 47 ML 44 L ML 14 5 L 25 n 1 4 9 2 9 10 12 RGG 2 2 part epoxy usually coincident with user selected scale datum Double sided adhesive tape Bolted P lim...

Страница 7: ...to cure fully then clean scale using Renishaw scle wipes A 9523 4040 or a clean dry lint free cloth Adhesive mounting installation 2 Mark area for epoxy on adhesive tape 1 RGH40 RGS40 G installation...

Страница 8: ...x 6 5 14 5 M3 x 0 5 x 6 5 23 5 0 1 34 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 5 5 Datum clamp Mounting clip 4 9 2 9 Dimensions and tolerances in mm RGS40 G glass scale installation drawing clip clamp m...

Страница 9: ...ean dry lint free cloth M 9550 0057 gap setting shim 4 Ensure scale can move so free to expand contract 1 2 mm 1 2 mm M 9550 0057 gap setting shim M 9550 0061 datum pad RGH40 RGS40 G installation guid...

Страница 10: ...able conformance to the installation tolerances allow adjustment to the rideheight of the readhead and be sufficiently stiff to prevent deflection or vibration of the readhead during operation For eas...

Страница 11: ...way D type plug L 12 way circular V 12 way circular coupling W 16 way in line connector X Power 5 V Brown 4 2 2 A Brown link 5 12 12 M 0 V White 12 10 10 B White link 13 11 11 N Incremental signals V1...

Страница 12: ...ers must ensure they comply with the lowest recommended counter input frequency Encoder velocity m s Resolution m x 4 safety factor Function Signal Colour 15 way D type plug D 16 way in line connector...

Страница 13: ...d from each other If the inner and outer shields are connected together this will cause a short between 0 V and earth which could cause electrical noise issues Electrical connections Grounding and shi...

Страница 14: ...P Resolution S A B Z Inverse signal not shown for clarity Synchronised pulse Z duration as resolution S Repeatability of position uni directional maintained within 10 C from temperature at time of pha...

Страница 15: ...ealing IP50 Acceleration Operating 500 m s2 3 axes Shock Non operating 1000 m s2 6 ms sine 3 axes Vibration Operating 100 m s2 max 55 Hz to 2000 Hz 3 axes Mass Readhead 50 g Cable 38 g m Cable 12 core...

Страница 16: ...our main website at www renishaw com contact M 9550 9023 01 RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countrie...

Отзывы: