![Renishaw H-2000-5015-05-N Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/renishaw/h-2000-5015-05-n/h-2000-5015-05-n_installation-and-user-manual_1441454017.webp)
MI 8
A-2037-0010
MI 8 interface unit complete with four M4 studded supports,
nuts and four adhesive feet.
MI 8/DIN
A-2037-0020
MI 8 interface for DIN rail mounting.
Fuse
P-FS01-0080
80 mA (T) anti-surge fuse.
One spare fuse is supplied with kit A-2037-0010
and kit A-2037-0020.
The output signal from the
interface must be compatible
with the machine’s control.
1-7
MI 8 OUTPUT SIGNAL
PARTS LIST - Please quote the Part no. when ordering equipment
Type
Part no. Description
Note:
Change of state debounce time
is 20 mS ± 5 mS.
Debounce time is the time delay
after the MI 8 has responded to
a probe trigger, before it can be
used again.
Solid state relay (SSR)
Normally closed (N/C).
or
Normally open (N/O).
(Teledyne 640-1 or equivalent).
Maximum current ±40 mA peak.
Maximum voltage ±50 V peak.
Closed
Open
Closed
Open
Contact bounce
Reseat
PROBE
STATUS
Move
clear
Trigger
point
SSR
OUTPUT
OPTIONS
At rest
Deflected At rest
Status N/C
Status N/O