Normally closed
(
N/C
)
Normally open
(
N/O
)
1-4
A1
PROBE INPUT
A2
PROBE INPUT
A3
SUPPLY SCREEN Connect to cable screen
A4
SUPPLY SCREEN Connect to machine earth
A5
SUPPLY
Po15 to 30 V d.c.
A6
SUPPLY
0 V
PIN DESCRIPTION COMMENTS
MI 8 CONNECTIONS
WIRING - PROBE to MI 8
Use two core screened cable.
Each core Ø2,5 mm (Ø0.10 in) maximum.
Maximum permitted length 30 m (98 ft).
Core
colours
MP4
TS20
TS27R
Blue
and
Red
Blue
and
Green
Probe
type
LP2
RP2
MP6-3
28 (1.1)
92 (3.62)
120 (4.72)
INPUT
POWER
SUPPLY
7,5 (0.29)
1,5 (0.06)
10,00
(0.39)
Blue
SWITCH SW1
Supply protection
80 mA (T) FUSE FS1
Remove cover to
access fuse
WARNING
For safe operation it is
essential to fit a fuse
of the correct rating
dimensions mm (in)
100 (3.93)
PROBE
INPUT
see table
opposite
Green
or red
63 (2.48)
60 (2.36)
45 (1.77)
+
0 V
A1
A2
A3
A4
A5
A6
▼
▼
LED