Port pair alignment checking procedure
In order to check the alignment of a port pair, the following procedure should be used:
Place the tool onto the alignment pins, as shown below, ensuring the alignment pins are seated in the levelling tool vee grooves.
If the port is correctly aligned, the bubble should be central within the graticule.
Placing the alignment tool onto the ACR2 port
NOTE:
If the alignment is found to be incorrect, the port pair alignment procedure should be repeated.
Rack reference
It may be useful to add a reference sphere to the rack pillar. The reference sphere can be used as a master reference for the position of the
rack pillar relative to the zero reference position of the machine.
ACR2 installation guide
www.renishaw.com
Issued 09 2020