This diagram shows the maximum tolerance acceptable on the CMM drive path during the automatic change cycle.
Nominal CMM drive path:
PHS axis origin position relative to pin datum point X
D
, Y
D
, Z
D
This table gives co-ordinates for the points in the automatic change cycle relative to the pin datum point X
D
, Y
D
, Z
D
calculated in step 8 of the
port datum procedure.
Point
X
Y
Z
A
+74
-135.5
+68.5
B
+74
+14.5
+68.5
C
+50
+14.5
+68.5
C1
+50
+14.5
-35.5
D
+50
+14.5
-31.5
E
+53.5
+14.5
-31.5
F
+53.5
-135.5
-31.5
ACR2 installation guide
www.renishaw.com
Issued 09 2020
27