Renfert
16 Maintenance
Easyclean MD
27 / 28
16 Maintenance
CAUTION
Faulty power cord
Electric shock or damage to the device
Ø
Check the power cord regularly for damage.
IMPORTA
NT
Keep the unit and tank clean and dry to prolong its service life. Regularly remove all dirt
residues and accumulated dust from the blower.
16.1 Replace the network cable
ü
The network cable or plug contacts are visibly damaged.
◦ Replace damaged network cables immediately.
NOTICE! Removable network cables may not be replaced with insufficiently measured
network cables!
è
The network cable has been replaced.
16.2 Clean enclosure
ü
The enclosure is dirty.
ü
The network cable is unplugged.
◦ Wipe all surfaces using a damp cloth.
WARNING! Do not spray the outside of the unit with water.
è
The enclosure has been cleaned.
16.3 Cleaning the tank
ü
The tank is full of limescale or dirty.
ü
The tank is empty.
1. Use a damp cloth to wipe out limescale and dirt residue. If necessary, rinse the tank using a
shower set.
CAUTION! Do not spray the outside of the unit with water.
ð
The tank has been cleaned.
2. To descale the tank, fill it with tap water up to the fill level marking in the tank.
3. Heat the unit up to 40 °C by pressing the
Heating
button.
4. Add 4–10% of Elma clean 60 or Elma clean 115C.
5. Once 40 °C have been reached, switch off the unit.
ð
Leave the solution to work for approx. 12 hours.
6. Then, switch on eco ultrasound mode for approx. 15 min.
7. Empty the tank.
8. Use a damp cloth to wipe out the remaining limescale and dirt residue. If necessary, rinse the
tank using a shower set.
CAUTION! Do not spray the outside of the unit with water.
è
The tank has been descaled and cleaned.