VDE4105, VDE 0126-1-1+A1, G83/2, G59/3, AS4777.2/.3

IEC62109-1&-2, AS3100, IEC62040-1

EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-3-11, EN61000-3-12

30

       

28

        

516*440*184mm

516*440*184mm

Protection

Residual current monitoring unit

Anti-islanding protection

DC switch(PV)

AC over current protection

Insulation monitoring

Certifications&Standards

Grid regulation

Safety

EMC

General Data

Dimensions (WxHxD) 

Weight (kg)

Mounting 

Ambient temperature range

Relative humidity

Moisture location category

Max. operating altitude

Protection degree 

Environment category

External environment pollution degree 

Topology

Standby losses(W)

Cooling 

Noise emision(dB)

Display

Communication

Standard warranty(years)

Integrated

Integrated

Integrated (optional)

Integrated

Integrated

Wall-mounted 

-25~60°C

 

(>45°C derating)

0~95%

4K4H

 2000m

IP65

Outdoor & indoor

Grade1

2

3

Transformerless

<8

Nature convection

<25

LED light & APP

USB2.0 or Wi-Fi

5/10/15/20/25 (optional)

Bracket

Model

Replus 5048ME

Replus 3648ME

*

listed in the table.

It is recommended that the total peak power of PV strings should not exceed 130% of maximum DC power of inverter 

10 Certificates

59

VDE0126-1-1

Note

Overvoltage category definition

Category I

  :

 applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a 

low level.

Category II 

:

 

applies to equipment not permanently connected to the installation. Examples

 

are appliances, portable tools and 

other plug-connected equipment; 

Category III

:

 applies to fixed equipment downstream of and including, the main distribution board. Examples are switchgear 

and other equipment in an industrial installation; 

Category IV

:

 applies to equipment permanently connected at the origin of an installation (upstream of the main distribution 

board). Example are electricity meters, primary overcurrent protection equipment and other equipment connected 

directly to outdoor open lines.

Environment category definition

Outdoor : the ambient air temperature is -20~50°C, Relative humidity range is 4 % to 100 %, applied to PD3

Indoor unconditioned: the ambient air temperature is -20~50°C, Relative humidity range is 5 % to 95%,applied to PD3

Indoor conditioned: the ambient air temperature is 0~40°C, Relative humidity range is 5 % to 85%,applied to PD2

Pollution

 

degree

 

d

efinition

Pollution degree 1

No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. 

Pollution degree 2

Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by 

condensation must be expected. 

Pollution degree 3

Conductive pollution occurs, or, dry, non-conductive pollution occurs which becomes conductive due to 

condensation which is expected. 

Pollution degree 4

Persistent conductive pollution occurs, for example, the pollution cause by conductive dust, rain and snow. 

Moisture
parameters

 

 

Level

Temperature Range

Humidity Range

3K3

0~+40℃
5%

~

85% 

4K2

-33~+40℃

15%

~

100% 

4K4H

-20~ +55°C 

4%

~

100% 

Moisture

 

location

 

category

 

definition

Содержание Replus 3648ME

Страница 1: ...rned off and disconnected to ensure safety in any installation operation The package product should be handled carefully and never be tipped over or slung 2 2 Safety Installation maintenance and conne...

Страница 2: ...n head screw 8 Flat head screw 5 Max 15 than the following value In consideration of heat dissipation and convenient dismantlement the minimum clearances around the inverter should be no less Upward 3...

Страница 3: ...ver and AC terminal Refer to Figure 4 1 2 7 Compress the terminal head by professional tool and screw down screw cap slight Refer to Figure 4 1 3 Figure 4 1 4 8 Insert AC terminals into the correspond...

Страница 4: ...breaker between inverter and battery 3 Disconnect screw cap from insulator 4 Disconnect waterproof ring from insulator 5 Put the cable through the components in this order screw cap waterproof ring i...

Страница 5: ...e terminal Negative terminal Figure 4 3 6 Figure 4 3 7 Hexagon head screw Pan head screw 4 5 EzMeter Connection EzMeter can detect the current magnitude and direction to control the working condition...

Страница 6: ...munication connects to EzConverter via CAN interface if lithium battery communication protocol is CAN Refer to Figure 4 6 2 Lithium battery communication connects to EzConverter via RS 232 interface i...

Страница 7: ...8 1 Figure 4 8 1 Open USB cover Touch switch 5 LED Lights Illustration 6 EzManage Operation Illustration Hybrid Series inverter has no LCD screen it can be controlled via mobile device with the APP so...

Страница 8: ...me charge is preferred Battery Selection Advanced Settings Feeding To Grid When the switch is yes excess energy of PV can feed to grid Shadow Scan When switch is on it can resolve the multiple wave pr...

Страница 9: ...ssfully created Please enter the registered user name and password when you created the solar station 7 Work Modes Hybrid series inverters have the following main work modes based on different conditi...

Страница 10: ...y Communication Fail Battery Output Short 8 Error Messages 9 Technical Parameters Model Category SUNCLIX MC4 Optional Replus 5048ME 5400 580 125 550 125 15 15 20 2 2 can parallel Lead acid or Li Ion 4...

Страница 11: ...installation Examples are appliances portable tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are swi...

Отзывы: