ReneSola Replus 3648ME Скачать руководство пользователя страница 10

An error message will be displayed on the APP if a fault occurs.

Table 8-1 is

 

the

 

Description of Error Message

Error message

Utility Loss

Fac Failure

PV Over Voltage

Over Temperature

Isolation Failure

Ground I Failure

Relay-Check Failure

DC Injection High

EEPROM R/W Failure

SPI Failure

DC Bus High

AC HCT Failure

GFCI Failure

Vac  Failure

Battery Over Temperature

Battery Under Temperature

Battery Cell Voltage Differences

Battery Over Total Voltage

Battery Discharge Over Current

Battery Charge Over Current

Battery Under SOC

Battery Under Total Voltage

Battery Communication Fail

Battery Output Short

Description

Grid disconnected

Grid frequency no longer within permissible range

Overvoltage at DC input

Overtemperature on the case

Ground insulation impedance is too low

Overhigh ground leakage current 

Relay self-checking failure

Overhigh DC injection 

Memory chip failure

Internal communication failure

Overhigh BUS voltage

Output current sensor failure

Detection circuit of ground leakage current failure

Grid voltage no longer within permissible range

Battery Over Temperature

Battery Under Temperature

Li-Ion Battery Cell Voltage Differences

Li-Ion Battery Over Total Voltage

Battery Discharge Over Current

Battery Charge Over Current

Battery Capacity Low

Battery Under Total Voltage

Battery Communication Fail

Battery Output Short

8 Error Messages 

9 Technical Parameters

Model

Category

 Ⅱ

SUNCLIX / MC4 (Optional)

Replus 5048ME

5400

580

125

~

550

125

15/15

20

2

2(can parallel)

Lead-acid or Li-Ion

48

4600

5-50  A continuous, programmable

>100AH(depending requirement)

3-stage adaptive with maintenance 

57V

included(Li-Ion)

integrated

integrated

4600

4600

1.5x Pnom, 10sec

20

30

Replus 3648ME

4200

580

125~550

125

15/15

20

2

2(can parallel)

Lead-acid or Li-Ion

48

4600

5-50  A continuous, programmable

>100AH(depending requirement)

3-stage adaptive with maintenance 

57V

included(Li-Ion)

integrated

integrated

3600

3600

1.5x Pnom, 10sec

16

24

99.9%

50/60Hz; 230Vac

45~55Hz/55~65Hz; 180~270Vac

230Vac ±2%, 50Hz ±0.2%, THDv<3%(linear load)

<1.5%

0.9 leading~0.9 lagging

Single phase

Category 

 

97.6%

97.0%

97.6%

97.0%

*

Solar

Max. DC  power(W)

Max. DC voltage (V)

MPPT voltage range (V)

Starting  voltage (V)

Max. DC current (A)

DC overcurrent protection(A)

No. of  DC connectors(Pr)

No. of  MPPTs

DC overvoltage category

DC connector

Battery

Battery  Type

Battery Rated

 

voltage  (V)

MAX Discharge power (W)

Charge current (A)

Battery capacity (Ah)

Charging curve

Charging voltage

Battery temperature compensation

Battery voltage sense

Current shunt

AC Output Data

Norminal AC power(W)

Max. AC power(W)

Peak power

 

(Back-up)(W)

Max. AC current(A)

AC overcurrent protection(A)

Norminal AC output 

AC output range

AC output (Back-up)

THDi

Power factor

Grid connection

AC overvoltage category

Efficiency

Max. efficiency

Euro efficiency

MPPT adaptation efficiency

19

20

Table 8-1

Содержание Replus 3648ME

Страница 1: ...rned off and disconnected to ensure safety in any installation operation The package product should be handled carefully and never be tipped over or slung 2 2 Safety Installation maintenance and conne...

Страница 2: ...n head screw 8 Flat head screw 5 Max 15 than the following value In consideration of heat dissipation and convenient dismantlement the minimum clearances around the inverter should be no less Upward 3...

Страница 3: ...ver and AC terminal Refer to Figure 4 1 2 7 Compress the terminal head by professional tool and screw down screw cap slight Refer to Figure 4 1 3 Figure 4 1 4 8 Insert AC terminals into the correspond...

Страница 4: ...breaker between inverter and battery 3 Disconnect screw cap from insulator 4 Disconnect waterproof ring from insulator 5 Put the cable through the components in this order screw cap waterproof ring i...

Страница 5: ...e terminal Negative terminal Figure 4 3 6 Figure 4 3 7 Hexagon head screw Pan head screw 4 5 EzMeter Connection EzMeter can detect the current magnitude and direction to control the working condition...

Страница 6: ...munication connects to EzConverter via CAN interface if lithium battery communication protocol is CAN Refer to Figure 4 6 2 Lithium battery communication connects to EzConverter via RS 232 interface i...

Страница 7: ...8 1 Figure 4 8 1 Open USB cover Touch switch 5 LED Lights Illustration 6 EzManage Operation Illustration Hybrid Series inverter has no LCD screen it can be controlled via mobile device with the APP so...

Страница 8: ...me charge is preferred Battery Selection Advanced Settings Feeding To Grid When the switch is yes excess energy of PV can feed to grid Shadow Scan When switch is on it can resolve the multiple wave pr...

Страница 9: ...ssfully created Please enter the registered user name and password when you created the solar station 7 Work Modes Hybrid series inverters have the following main work modes based on different conditi...

Страница 10: ...y Communication Fail Battery Output Short 8 Error Messages 9 Technical Parameters Model Category SUNCLIX MC4 Optional Replus 5048ME 5400 580 125 550 125 15 15 20 2 2 can parallel Lead acid or Li Ion 4...

Страница 11: ...installation Examples are appliances portable tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are swi...

Отзывы: